           GENERAL SPECIFICATION                                                                                                                           Construction Notes
   ALL BUILDING WORK TO BE CARRIED OUT TO THE BUILDING CODE OF AUSTRALIA & THE BUILDING ACT 1975.                                       Timber Frame: Framing to be built in accordance with AS 1684 Termite protected timbers shall be used on all framing
   BUILDER TO SUPPLY FOOTPATH PROTECTION & REQUIRED SIGNS TO COMPLY TO WORKPLACE HEALTH & SAFETY ACT.                                   Approved type flashing & sarking to be attached between cladding & frame along with slab & frame to prevent moisture
   PRINCIPLE CONTRACTOR TO HAVE A SITE SPECIFIC WORKPLACE HEALTH & SAFETY MANAGEMENT PLAN TO COMPLY WITH                                getting to the frames
   GOVERNMENT REGULATIONS TO BE KEPT ONSITE & GIVEN TO ALL CONTRACTORS
   WRITTEN DIMENSIONS TO TAKE PRECEDENCE OVER SCALE.                                                                                    All wet areas to be made waterproof or resistant to comply to AS 3740 & BCA 3.8.1
   BUILDER TO VERIFY ALL SET-OUT DIMENSIONS PRIOR TO PLACEMENT OF CONCRETE                                                              Linings used shall be approved for use in wet areas & shall be fixed in strict accordance
   BUILDING MUST COMPLY WITH THE NATIONAL CONSTRUCTION CODES (BCA) & THE QUEENSLAND HOME BUILDING CODE                                  with Manufactures specifications.
   ALL CONCRETE SLABS & FOOTINGS TO COMPLY WITH (AS 2870)                                                                               Wet Areas include Laundry
   ALL STRUCTURAL TIMBERS TO COMPLY WITH NATIONAL TIMBER FRAMING CODES (AS1684.2 &AS1720) & CONSTRUCTION TIMBERS
   IN QUEENSLAND (CTIQ)                                                                                                                 All walls to be checked to ensure they are fixed correctly, straight & plumb prior to fixing plasterboard or interior lining
   TERMITE PROTECTION TO (AS3660.1) CERTIFICATES TO BE SUPPLIED & GIVEN TO CERTIFIER                                                    Plasterboard or interior linings to be fixed to dry frames in strict compliance with manufactures details. Setting of
   ALL WET AREAS TO BE WATERPROOFED, INTERNAL WATERPROOFING TO COMPLY TO (AS 3740) AS IN BCA 3.8.1                                      plasterboard to be done in strict compliance with manufactures specifications, Sanded to provide a flat smooth finish
   ALL GLASS TO COMPLY TO (AS 1288) WINDOWS & DOORS ALONG WITH SCREENING OR SECURITY SCREENS TO COMPLY TO
   RELEVANT REGULATIONS                                                                                                                 Painting: Paints & application to comply to AS 2311 Min 3 coat application system to be used
   PLASTERBOARD TO (AS 2589), PAINTING TO COMPLY TO (AS 2311) TILING TO COMPLY TO (AS 3958)                                             Substrate to be clean & dry correct type sealers & primers to be used for substrate
   STAIRS TO COMPLY TO BCA 3.9.1 BALUSTRADE TO COMPLY TO BCA 3.9.2,                                                                     If paint is sprayed on then a back roll should be done between coats & after final coat
   WIND CLASSIFICATION (N3).                                                                                                            Mould resistant paint to be used in Bathrooms, Ceilings to have approved ceiling paint applied & be a matt finish

                                                                                                                                        Concrete slabs & footings to be poured AS per Plans & in accord with AS 2870
                                                                                                                                        Slabs shall be finished to suit floor coverings

                                                                                                                                        All external windows & doors to have appropriate flashing & seals fitted to prevent water getting into building or
                                                                                                                   -                    to the frame work
                                                                                                          NOOSA COUNCIL
                                                                                                         APPROVED PLANS
                                                                                                     51983.3225.03 11 NOV 2014




Not for construction or certification
Client: Alison Payne      Unit 22 The Hastings Noosa Parade Noosa Heads                   Wind Classification N3                                                                                                                            Date      22/07/2014 6:25:40 AM
                                                                                                                       ACCOLADE Building Designs
RPD: Lot 22 on GTP 1154         Parish: Weyba       County: March       Site Area : 105 m²                                Proprietor: Steven Horn                                   Mobile: 0407 693 018          Drawn for A3 Sheet
Proposed Partial Enclosure of Ground Level Under Unit                                                                                                                        Email: [email protected] Scale      Sheet No. 1 of .

Used in these records

About this file

File size
8.5 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Compiled Approved Plans 51983.3225.11.pdf · 8.5 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.