Council archive · source document
Attachment B - Engineering plans · MCU17/0004.01
Attached to the e-mail Change to Development Approvals - MCU17/0004.01 & OPW17/0005.01.
Attached to the e-mail FW Lodgement of Operational works application - 46- 48 Elizabeth Street Noosaville.msg.
Plans and drawings: the text below has words only, no drawings.
BM: NAIL IN KERB
RL: 1.600
55 57
1. 47
57
1. .35
40
44
43
54
61
1. 1.
48
8
1.
1.
1.
1.
1.
1
1.
5
1.
PP PP
51
1. .59
56
1.
55
54
50
1
54
1.
1.
1.
1.
5
40
5
WM
1.
1.
WM
66
4
1.
5
03
1.
58
20.92 20.92
58
2.
1.
9
64
1.
5
1.
1.
COMMON PROPERTY
94
1.
66
1.
RP78252
17.10
2
2 STOREY
74
BRICK UNITS
1.
35.46
67 2 GTP395
59
1. 630m²
1.
6.09
77
72
3
66
1.
1.
1.
742m²
SHED
35.46
GTP156216
68
1.
18.36
DECK
IO
MH
LL: 1.53
CP
49
IL: 0.52
1.
65
50
47
1.
1.
1.
14.83 20.92
60
1.
2 STOREY 6 GTP671
SINGLE STOREY
4 RP72986 BLOCK & H'PLANK
BLOCK UNITS
Issue:
Unit 1/11 Project Ave,
Noosa Heads
Ph (07) 5455 5604
DEBUILD T/A
email:[email protected]
web:www.scg-engineers.com
ABN 40 098 481 899
Title:
Project
Date: Drawn
Checked: Drg No. Rev.
Rev. - 10.06.16
[OCR of page images]
DRAWING SIZE — Al
LOTS 2 & 3 ON RP 78252
Level Datum AHD
7
Level Origin PM 56277, RL 1.635m
www.dialbeforeyoudig.com.au
———
DIAL1100
BEFORE YOU DIG
PROPOSED LOT 2 & 3 INSTALL DOMESTIC 25 Diam
BRANCH CONNECTION AND METERS FROM WATER MAIN
IN ACCORDANCE WITH UNITYWATER SPECIFICATIONS &
DETAILS. UNITYWATER APPROVAL TO BE OBTAINED
ALL WORKS BY UNITYWATER AT DEVELOPERS COST.
REFER TO HYDRAULIC CONSULTANTS DRAWINGS FOR
METER REQUIREMENTS.
NEW 259 DIAMETER
BRANCHES FROM WATER
MAIN
INTERNAL WATER SUPPLY,
RETICULATION BY HYDRAULICS
CONSULTANT. TYPICAL.
8252
6 ° . 4
_—e— aes fe E
a RP -BOUN oa
mi [s 2 v
| Pepe | POO
7 Le.
= |
3)
3 |
=! UNIT 1
& | FFL 2.70 | 2
| UNIT 2 as
| ie FFL 2.70 BR
\ 1s GTP395
8 & | | __ SIPS
F| —
SHED | jo
UNIT 4 |
FFL 2.70 ! =
( g
e | UNIT 3 3 GTP pt
© “| J FFL 2.70 8
~* ' a
me &
° 10
RP72986
SITE PLAN — WATER SUPPLY
Scale 1: 200
CONTRACTOR TO LOCATE ALL SERVICES PRIOR TO
COMMENCING WORKS ON SITE, ALL SERVICES ARE
TO BE PROTECTED IN ACCORDANCE WITH THE
AUTHORITY RESPONSIBLE FOR THE SERVICE
LEGEND.
48.0
a
wv
<
FALL
w
+
EXISTING PROPERTY
BRANCHES & METERS TO BE
CAPPED OFF & REMOVED.
TYPICAL, sw
w/e. —
Qa INDICATES EXISTING SURFACE
CONTOUR AND LEVEL 10 AHD.
EXISTING SURFACE SPOT LEVELS.
INDICATES PROPOSED FINISHED
SURFACE LEVELS
INDICATES DIRECTION OF FALL
TO FINISHED SURFACES.
INDICATES OVERHEAD ELECTRICITY
SUPPLY LINE
INDICATES EXISTING SEWER LINE
INDICATES PROPOSED SEWER LINE
INDICATES WATER MAIN APPROX
ALIGNMENT, BUILDER TO CONFIRM
EXACT LOCATION PRIOR 10 WORKS
INDICATES TELSTRA LINE APPROX
ALIGNMENT, BUILDER TO CONFIRM
EXACT LOCATION PRIOR 10 WORKS
INDICATES STORMWATER DRAIN
PROPOSED AS NOTED MIN 1 IN
100 FALL UNLESS NOTED
OTHERWISE
INDICATES STORMWATER DRAIN
EXISTING AS NOTED MIN 1 IN 100
FALL UNLESS NOTED OTHERWISE
IK
GENERAL:
1, DO NOT SCALE FROM THIS DRAWN,
2. ALL DIMENSIONS IN MILLIMETRES
‘3. SETTING OUT DMENSIONS ARE TO BE OBTANED FROM THE
[ARCHITECTURAL DRAWINGS.
4, ANY DISCREPANCIES BETWEEN THESE DRAWING AND THE
ARCHITECTURAL ORAWINGS ARE TO BE REFERRED TO THE ENGINEER
IMMEDIATELY.
5. THE BUILDER IS RESPONSIBLE FOR LOCATING AL EXSTNG
SERVCES WITHIN AND ADJACENT THE ALLOTMENT AND SHALL ENSURE
THAT ALL NEW WORKS ARE IN ACCORDANCE WITH THE ATTACHED
CRITICAL DEPTH UNE DIAGRAM,
FOOTPATHS AND DRIVEWAYS:
|. EXISTING FOOTPATHS TO BE SAW CUT PRIOR TD REMOVAL
2. CROSSINGS ARE NOT DESIGNED FOR COMMERCIAL VEHICLES
‘3. CONCRETE DRIVEWAY TO BE 125mm THK. EXCLUDING ANY
FISHED TREATMENTS, EG. STANPING
4 CONCRETE SURFACE TOLERANCE +5.nm OVER 3.0m
5, CONCRETE N25 IN ACCORDANCE WITH AS 1379 AND AS 3600
6. REINFORCEMENT FABRIC TO AS 1304, PLACED CENTRAL SLAB
DEPTH,
7. EXPANSION JOINTS 10 BE 10mm WOE WET TOOLED WTH EVERY
2ND MESH WRE CUT ALONG JON,
1 ONE ACCESS PONT PERMITTED FOR EACH ALLOTMENT,
9. FOR CURVED DRIVEWAYS, MAMMUM GRADES APPLY TO INSIDE
EDGE OF CURVE
10. ALL SERVICES TO BE LOCATED AND PROTECTED AS REQUIRED
PRIOR TO WORK COMMENCING
HYDRAULICS
1, HYDRAULIC SERVICES SHOWN ARE DIAGRAMATIC ONLY, REFER TO
ARCHITECTURAL DRAWINGS FOR LOCATIONS OF FIXTURES.
2, ALL SANTARY HYDRAULICS AND WATER RETIOULATION WITHIN THE
ALLOTMENT BOUNDARY TO BE IN ACCORDANCE WTH AS3500.
3. ALL WORK SHALL COMPLY WTH THE RECUREMENTS OF AUTHORITIES
HAVING JURISDICTION, AFTER OBTAINNG ALL NECESSARY PERMITS AND
APPROVALS,
4, THE CONTRACTOR IS TO CONFIRN THE POSITON OF ALL ESTING
SERVICES AS NOICATED ON THESE AND ASSOGATED PLANS PRIOR TO
THE COMMENCING OF WORK.
5, STORMWATER DRANAGE PIPES SHALL BE CLASS SH UPVC OR CLASS
2. RCP RUBBER RING JONTED PIPE AS NOTED LAID AT A MINMUM
GRADE OF 1 IN 100 UN, JOINS ARE TO BE CONSTRUCTED IN
ACCORDANCE. WITHTHE MANUFACTURERS REQUIREMENTS,
6 SEWERS 100MM DIAM, UPVC UNO. AND LAD AT A MIMUM GRADE
oF 1 60,
7, WATER SUPPLY PIPEWORK BELOW GROUND 1S TO BE ;
53UM DIAM, OR LESS — HIGH DENSITY TYPE. 50,
CLASS 12 POLYETHYLENE
8. ALL ABOVE GROUND AND INTERNAL WATER SUPPLY PIPEWORK TO BE
TYPE B COPPER.
9, WATER SERVIOES ARE NOT PERMTTED IN GROUND SLABS AND ALL
OWNS AND CONNECTIONS SHALL BE MADE ABOVE THE SLAB
10. ARE HYDRANTS ARE TO BE INSTALLED ARE TO BE INSTALLED IN
ACOORDANOE WITH ASZ419.1. HOSE REELS ARE TO BE INSTALLED IN
ACOORDANGE WITH AS2441
11, CLEAN-OUTS, INSPECTION OPENINGS AND CLOSING CAPS SITUATED IN
VEHICULAR OR PEDESTRIAN PAVEMENTS ARE TO GE FITTED WT EITHER
BRASS OR CAST-IRON COVERS.
12. ALL IN-GROUND VALVES SHALL BE IN ACCORDANCE IN APPROVED
CONCRETE PATH BOXES.
13. ALL WASTE PIPES AND WATER SERVICES PENETRATING SLABS TO BE
WRAPPED IN AN APPROVED FLELE JOINT JOINT WRAPPING.
14, THE TERM SERVICE’ REFERS TO THE MNMUM INTERNAL PIPE
DIAMETER UNLESS NOTED OTHERWISE.
KE
EX. SWPT EXISTING STORMWATER MANHOLE /PIT
EX. SCP EXISTING SEWER CONNECTION POINT
RC. HW. REINFORCED CONCRETE HEADWALL
EX. SMH EXISTING SEWER MANHOLE
EX. SWMH EXISTING STORMWATER MANHOLE
EX. WM EXISTING WATER METER
E.0B. EXISTING EDGE OF BITUMEN
kK &C EXISTING KERB & CHANNEL
NSL NATURAL SURFACE LEVEL
FH. FIRE HYDRANT
TP TELSTRA PIT
EP. ELECTRICAL POWER POLE
KERB EXISTING KERBING
sv STOP VALVE
C__| AMENDED FOR NEW ARCHTEGTURALS | 09.04.17
B.__|_SEWER/BRANCH EASEMENT RELOCATED] 08.11.17.
‘A | UNITY WATER REVISIONS TO WATER. | 23.08.17.
Revision | Deseription Date
Ts
“FOR APPROVAL
DO NOT SCALE FROM THIS DRAWING
‘The design and ossucited deals contsned on this ond associated
tawings ere expyight ond re rot to be used or reprodiced wihaut
the wiles parmision of SCE Conslng Engineers
=~ Unit 1/11 Project Ave,
Noosa Heads
Ph (07) 5455 5604
a senalacnni@sepergneascon
wena sogengineers.com
“OPERATIONAL WORKS:
| WATER SUPPLY
Lots 2 & 3 RP78252
Elizabeth St, NOOSAVILLE
Date: Drawn
Nov 16 SK
| Fass. t 26281-0W5| C.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Attachment B - Engineering plans.pdfRelated documentApplication case desk ↗
Attachment B - Engineering plans.pdfRelated documentApplication case desk ↗
Attachment A - Engineering plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 3.8 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.