Council archive · source document
Attachment B - Engineering plans · MCU17/0004.01
Attached to the e-mail Change to Development Approvals - MCU17/0004.01 & OPW17/0005.01.
Attached to the e-mail FW Lodgement of Operational works application - 46- 48 Elizabeth Street Noosaville.msg.
Plans and drawings: the text below has words only, no drawings.
BM: NAIL IN KERB
RL: 1.600
57
7
7
1. .35
1. .40
61
55
44
3
4
5
1.
48
1.
54
4
8
1.
1.
1.
1.
1
1
1.
5
1.
PP PP
1
.5
59
1 5 6
1.
5
54
50
1. 5
54
1.
1.
1.
1.
55
4 0
WM
1.
1.
WM
66
54
1.
3
1.
58
0
20.92 20.92
58
2.
1.
59
4
1.
6
1.
1.
COMMON PROPERTY
94
1.
66
1.
RP78252
17.10
2
4 2 STOREY
7
1. BRICK UNITS
35.46
67 2 GTP395
59
1. 630m²
1.
6.09
7
72
3
66
.7
1.
1
1.
742m²
SHED
35.46
GTP156216
68
1.
18.36
DECK
IO
MH
LL: 1.53
IL: 0.52
1.
49 CP
50
47
65
1.
1.
1.
0 14.83 20.92
6
1.
2 STOREY 6 GTP671
SINGLE STOREY
4 RP72986 BLOCK & H'PLANK
BLOCK UNITS
Issue:
Unit 1/11 Project Ave,
Noosa Heads
Ph (07) 5455 5604
DEBUILD T/A
email:[email protected]
web:www.scg-engineers.com
ABN 40 098 481 899
Title:
Project
Date: Drawn
Checked: Drg No. Rev.
Rev. - 10.06.16
[OCR of page images]
DRAWING SIZE — Al
Level Datum AHD
|
H LOTS 2 & 3 ON RP 78252
| Level Origin PM 56277, RL 1.635m
N
BOUNDARY
BLOCK BOUNDARY
WALL AS SPECIFIED.
FLLED ALLOTMENT
v a
FILLED ALLOTMENT
1809 ADJOINING DRAIN FROM
GRATE CONNECT TO 1508 UPVC ie
~ RECTANGULAR GRATE OVER,
PLAGE AT LOW PONTS
ALONG NEIGHBOURING BLOCK
y
SHEL» TYPICAL DETAIL
1509 uPVC 1 in 100 GRADE TO STORM WATER
PIT ON STREET. IL TO MATCH EXISTING GL IN
NEIGHBOURING PROPERTY.
SECTION X-X
LF RAINFALL,
ROOF RUNOFF
INFILTRATION PITS
TREAT FIRST FLUSH RUNOFF FROM ROOF'S
~STORAGE AND ONGOING INFILTRATION
REDUCES DEVELOPED SITE RUNOFF
COUNCIL STORMWATER
SYSTEM
WATER CYCLE DIAGRAMATIC
www.dialbeforeyoudig.com.au
DIAL1100
BEFORE YOU DIG
BLOCK RETANING
WALL
suing
2
2/125x75x4.0 RHS (GALV.)
LAID AT 1 in 100 MIN,
INSTALL TO NEW KERB
ADAPTORS AND MAKE
FOOTPATH GOOD.
EXISTING GROUND LEVEL IN
NEIGHBOURING PROPERTY.
AUSDRAIN ENVIROMODULE 2
INFILTRATION CELLS. REFER
DETAIL ON THIS SHEET.
CREATE FALL TOWARD
ROAD RESERVE IN FINISHED
GROUND PROFILE.
THIS SWP PROVIDED AS
DISCHARGE POINT FOR
NEIGHBOURING ALOTMENT
DRAINAGE.
EXISTING HCB's & NEW SW DRAINAGE
LINE 10 BE PROTECTED AS PER
SEWER/STORMWATER PROTECTION
DETAILS ON DRG 26281-OWt
2/125x75x4.0 RHS (GALV.)
LAID AT 1 in 100 MIN.
INSTALL TO NEW KERB
ADAPTORS AND MAKE
FOOTPATH GOOD.
EX. SCP
SW.
sw.
AS
3
HATCHING INDICATES PROPOSED 4
1.0m WIDE EASEMENT FOR
INTER-ALOTMENT DRAINAGE.
SITE PLAN — STORMWATER MANAGEMENT
Scale 1 : 200
CONTRACTOR TO LOCATE ALL SERVICES PRIOR TO
COMMENCING WORKS ON SITE. ALL SERVICES ARE
TO 8E PROTECTED IN ACCORDANCE WITH THE
AUTHORITY RESPONSIBLE FOR THE SERVICE
THIS DRAWING IS TO BE READ IN. CONJUNCTION
WITH THE STORMWATER MANAGEMENT REPORT BY
SCG CONSULTING ENGINEERS (No. 25231(SWM)
ALL PIPES TO BE LAID AT 1 IN 100 MIN
UNLESS NOTED
1.0m
STORMWATER
INFLOW t
\ FALL LANDSCAPED AREAS 10
\ FORMED FLOW PATHS TO DIVERT
RUNOFF TO SW PITS. 1 in 100
MIN FALL. TYPICAL.
AUSDRAIN ENVIROMODULE 2
INFILTRATION CELLS 10 IN LINE,
WRAPPED IN GEOFABRIC
LOS
0
LEGEND
INDICATES EXISTING SURFACE
4800
CONTOUR AND LEVEL TO AHD.
oe
* EXISTING SURFACE SPOT LEVELS.
INDICATES DIRECTION OF FALL
TO FINISHED SPOON DRAINS.
INDICATES PROPOSED FINISHED
SURFACE LEVELS
150(W) GRATED DRAIN WITH
HEAVY DUTY GRATE.
450Sq PIPE JUNCTION BOX WITH
BOLTED LID, PRE-CAST
CONCRETE.
450Sq FIELD INLET, PRE-CAST
CONCRETE WITH RAISED GRATE FOR
LANDSCAPED AREA DRAINAGE.
oP
300Sq FIELD INLET, PRE-CAST
ELIZABETH STREET FE) CONCRETE WTH RAISED GRATE FOR
FALL LANDSCAPED AREAS TO LANDSCAPED AREA DRAINAGE.
FORMED FLOW PATHS TO DIVERT &
[— RUNOFF TO GRATED DRAINS AND 2/125x75x4.0.RHS (CALY.) &S STORMWATER VERT. INLETS TO
SW PITS. 1 in 100 MIN FALL. LAID AT 1 in 100 MIN. [I ~—COLLECT PONDING FROM
TYPICAL. INSTALL TO NEW KERB NEIGHBORING PROPERTY.
ADAPTORS. AND MAKE REFER DETAIL
2 Ss 2 FOOTPATH 6000. ; INDICATES PROPOSED STORMWATER
— T g 2S sw DRAIN EXISTING MIN t in 100
—£—{_—T1r £3 nEep GRADE U.N.O
oF i
eT Yi i" Wan " OP DENOTES APPROXIMATE DOWNPIPE
_ =P -BOUNBARY —_ LOCATIONS TO BE CONFIRMED BY
i! See} — ARCHITECT AND HYDRAULIC
POOL =| DESIGNER
| POOL AUSDRAIN ENVIROMODULE 2
>! INFILTRATION CGELLS. REFER
S| 1508 uPVC @ 1:100 5 “ll, DETAIL ON THIS SHEET.
3
3| OP 1009 uPYe, @ 1:100
' ae HATCHING INDICATES PROPOSED
8252 S| \t s 1.0m WIDE EASEMENT FOR
oF UNIT 1 | INTER-ALOTMENT DRAINAGE,
| FFL 2.70 2
1 S
{oa
—_—_ = LOCATE STORMWATER PITS
sue] © Io — AT LOW POINT ON
g S NEIGHBOURING PROPERTY
& UNIT 4 [om REFER TYPICAL DETAIL.
3 FFL 2.70 V7 AP &
UNIT 3 2 ori
a FFL 270 ois
o ’
=
NN 4
PROVIDE INSPECTION OPENINGS
(|.0.S) FROM SLOTTED PIPE IN
BASE FOR FLUSH OUT or
OVERFLOW GRATE WHERE NO
STORMWATER OUTLET
-
V0.5 STORMWATER
OT OUTFLOW
[3
AK
a
PROVIDE DROPS AT EACH END
OF THE PIT FROM THE MAIN
PROVIDE SLOTTED PIPE
‘—— THROUGH BOTTOM OF
CELLS
AUSDRAIN_ INFILTRATION SOAKER PIT DETAIL
THROUGH DRAIN 10 THE
SLOTTED PIPE IN THE BASE
ALL PIPE PENETRATIONS THROUGH THE GEOFABRIC TO
BE FITTED WITH STAINLESS STEEL PIPE CLAMPS,
GEOFABRIC TO BE LAPPED AT JOINS WITH A ROOT
INHIBITOR PROVIDED ALONG THE JOIN LINES
CONSTRUCTION NOTES,
GENERAL:
1. DO NOT SCALE FROM THS DRANG,
2. ALL DIMENSIONS IN MILLMETRES
‘3. SETING OUT DMENSONS ARE TO BE OBTAINED FROM THE
"ARCHITECTURAL DRAWINGS.
4, ANY OISCREPANES BETWEEN THESE ORAWNG AND THE
ARCHITECTURAL ORAWINGS ARE TO BE REFERRED TO THE ENGINEER
IMMEDIATELY
5. THE BULDER IS RESPONSIBLE FOR LOCATING ALL EXSTNG
SERVICES WTHIN AND ADJACENT THE ALLOTMENT AND SHALL ENSURE
THAT ALL NEW WORKS ARE IN’ ACCORDANCE WTH THE ATTACHED
CRITICAL DEPTH LINE DIAGRAM.
FOOTPATHS AND DRIVEWAYS:
1. DISING FOOTPATHS TO BE SAW CUT PRIOR TO REMOVAL
2. CROSSINGS ARE_NOT DESIGNED FOR COMMERCIAL. VEHICLES
‘3. CONCRETE DRVEWAY TO BE 125mm THK. EXCLUDING ANY
FINSHED TREATMENTS, EC. STAMPING
4 CONCRETE SURFACE TOLERANCE +5.0mm OVER 3.0m
5. CONCRETE N25 IN. ACCORDANCE NTH AS 1379 AND AS 3600
6. REINFORCEMENT FABRIC TO AS 1304, PLACED CENTRAL SLAB
7, EXPANSION JOINTS TO BE 10mm WDE WET TOOLED WITH EVERY
2ND MESH WRE CUT ALONG JONT,
{8 ONE ACCESS PONT PERMITTED FOR EACH ALLOTMENT.
9, FOR CURVED DRIVEWAYS, MAKMUM GRADES APPLY TO INSIDE
EDCE OF CURVE
10, ALL SERVCES 10 BE LOCATED AND PROTECTED AS REQUIRED
PRIOR TO WORK COMMENGNS
HYDRAULICS
1. HYDRAUUC SERVICES SHOWN ARE DIAGRAMATIC ONLY. REFER TO
[ARCHITECTURAL DRAWINGS FOR LOCATIONS OF FXTURES.
2. ALL SANTARY HYDRAULICS AND WATER REGULATION THIN THE
'AILOTMENT BOUNDARY 70 BE IN ACCORDANCE. WITH AS3500.
‘3. ALL WORK SHAUL COMPLY WH THE REQUREMENTS OF AUTHORIMES
HAVING JURISDICTION, AFTER OBTANNG ALL NECESSARY PERMITS AND
APPROVALS,
4 THE CONTRACTOR IS TO CONFIRM THE POSTON OF ALL EXSTING
SERVICES AS INDICATED ON THESE AND ASSOCIATED PLANS PRIOR TO
THE COMMENCING OF WORK.
5, STORMWATER DRANAGE PIPES SHALL BE CLASS SH UPVC OR CLASS
‘2 RCP RUBBER RING JONTED PPE AS NOTED LAD AT A MINMUM
(GRADE OF 1 IN 100 UNO. JOINS ARE TO BE CONSTRUCTED IN
‘ACCORDANCE WTH THE MANUFACTURERS REQUIREMENTS.
6, SEWERS 100MM DIAM. UPVC UN.O. AND LAD AT A MAIMUM GRADE
OF 1 WN 60,
7. WATER SUPPLY PPEWORK BELOW GROUND 15 TO BE ;
63MM DIAM, OR LESS ~ HIGH DENSITY TYPE 50
CLASS 12 POLYETHYLENE
8. ALL ABOVE GROUND AND INTERNAL WATER SUPPLY PPEWORK TO BE
TYPE B COPFER,
9, WATER SERVICES ARE NOT PERMITTED IN GROUND SLABS AND ALL
ONS AND CONNECTIONS SHALL BE MADE ABOVE THE SLAB.
10, FIRE HYDRANTS ARE TO BE INSTAILED ARE TO BE STALLED IN
[ACCORDANCE WTH ASZ419.1. HOSE REELS ARE TO BE INSTALLED IN
‘ACCORDANCE WITH AS2441.
1, CLEAN-OUTS, INSPECTION OPENINGS AND CLOSING CAPS STUATED IN
VEHICULAR OR PEDESTRIAN PAVEMENTS ARE TO BE FITTED WTH EITHER
BRASS OR CAST-IRON COVERS.
12, ALL IN~GROUND VALVES SHALL BE IN ACCORDANCE IN| APPROVED
(CONCRETE PATH BOXES.
13, ALL WASTE PIPES AND WATER SERVICES PENETRATING SLABS TO BE
WRAPPED IN AN APPROVED FLEMELE ONT JOINT WRAPPING
14, THE TERM SERVICE” REFERS TO THE MINMUM INTERNAL PIPE
DIAMETER UNLESS NOTED OTHERWSE,
KEY.
EX. SWPT EXISTING STORMWATER MANHOLE/PIT
EX. SCP EXISTING SEWER CONNECTION POINT
RC. HW. — REINFORCED CONCRETE HEADWALL
EX. SMH EXISTING SEWER MANHOLE
EX. SWMH EXISTING STORMWATER MANHOLE
SWMH NEW 1050 STORMWATER MANHOLE
E.0.8. EXISTING EDGE OF BITUMEN
K &C EXISTING KERB & CHANNEL
NS.L NATURAL SURFACE LEVEL
FH, FIRE HYDRANT
TP TELSTRA PIT
EP. ELECTRICAL POWER POLE
KERB EXISTING KERBING
8 __| SW & DRIVEWAY LEVELS AMENDED, [19709717
'SWP's_ADDED TO SATISFY COUNCIL
A _|inro"eeauesr itew 1 (wcut7/o004) | 07/02/17
Revision
"FOR APPROVAL
DO NOT SCALE FROM THIS DRAWING
‘The design and ossucited deals contsned on this ond associated
tawings ere expyight ond re rot to be used or reprodiced wihaut
the wiles parmision of SCE Conslng Engineers
C) sce
OPERATIONAL WORKS:
STORMWATER MANAGEMENT
Lots 2 & 3 RP78252
Elizabeth St, NOOSAVILLE
Description Date
Unit 1/11 Project Ave,
Noosa Heads
Ph (07) 5455 5604
senalacnni@sepergneascon
wena sogengineers.com
a enorme
Pate! Nov 16 | csk
Checked DrgNo
| RSs, N |26281-Swi | B.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Attachment B - Engineering plans.pdfRelated documentApplication case desk ↗
Attachment B - Engineering plans.pdfRelated documentApplication case desk ↗
Attachment A - Engineering plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 3.8 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.