3.3 Amenity
It is expected that the waste storage area will be aesthetically designed to be
consistent with the development with enclosures matching surrounding finishes, with
or without a roof.
Where enclosed, waste storage areas are to be ventilated in accordance with AS 1668
and the applicable requirements of SC6.10 - PSP9 Waste Management.
Sufficient facilities shall be provided to enable wash down of waste storage
containers. This area will generally include:
a floor graded to fall to a drainage point located within the wash down area
drainage by means of a trapped gully connected to the sewer, and is designed
to prevent rainfall and other surface water entering the wash down area
a hose cock located in the vicinity of the wash-down area.
Waste storage areas will be regularly cleaned to deter vermin. Traps and other pest
control measures will be used to monitor and exterminate pests.
3.4 Signage
Bins will be clearly signposted to ensure residents use the appropriate bin for each
waste stream. Example signage is provided in Figure 3-4. A no-standing sign is
recommended in front of the northern bin bays to maintain collection access at all
times.
Figure 3-4 Bin Signage