Appendix A - Bushfire Hazard Assessment & Management Plan
Attached to the e-mail RAL20/0014 - Response to Council's Information Request - 9A Jirrima Cres, Cooroibah - Email 01 of 02.
The original of this document is very large (14.0 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawnBushfire Hazard Assessment & Management Plan v1 NCES REF: J000706 Lot 101 on SP168341 – 9a Jirrima Cres, Cooroibah 3.3 Quantitative Modelling Quantitative modelling of the potential bushfire conditions that may be experienced within the VHC 22.1 Melaleuca open forest within the site has been undertaken to gain an appreciation of the severity of risk acting on the site including exposure to direct flame contact and radiant heat. An understanding of the latter is used to determine the dimensioning of asset protection zones to satisfy the SPP requirements. The models used comprise industry standard bushfire equations which have been built into the FPAA endorsed FLAMESOL computer model. FLAMESOL allows numerous input variables to be adjusted including fuel loads, fire danger index, site slope and distance to vegetation. FLAMESOL uses the following algorithms: DRAFT NOT FOR SUBMISSION PURPOSES • Rate of Spread – McArthur (1973) and Nobel et al. (1980) • Flame Length – NSW Rural Fire Service (2001) and Nobel et al. (1980) • Elevation of Receiver – Douglas and Tan (2005) • Flame Angle – Douglas and Tan (2005) • Radian Heat Flux – Drysdale (1999), Sullivan et al. (2003) and Douglas and Tan (2005) The FLAMESOL Minimum Distance calculator has been used and comprises an AS 3959:2018 Method 2 (Appendix B) based calculator which populates standard bushfire behaviour variables as well as the minimum distances required to achieve a range of different radiant heat level exposures, including those which correspond with the range of Bushfire Attack Levels (BAL’s) prescribed under AS 3959:2018 Construction of Buildings in Bushfire Prone Areas. Fuel load inputs have been drawn from Planning for Bushfire Resilient Communities (QFES 2019) based on the calculated potential fuel loads for VHC 22.1 (23.4 t/ha surface and near surface fuels and 28.4 t/ha total fuels). 1º effective slope was adopted for the slope underlying the VHC 22.1 Melaleuca Open Forest. A FDI of 47 has been adopted for the site consistent with the assignment by QFES (Catalyst 2020) (refer Plate 9). © 2020 15
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.