Original source · versioned page text
Attachment 1 Proposal Plans
Attached to the e-mail MCU15/0045 Application for Detached House - IDAS forms, Planning Report, Stability Report - Email 1 of 2.
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn CONSTRUCTION NOTES
GENERAL ALL WORK TO COMPLY WITH BUILDING CODE OF AUSTRALIA AND ITS MOST CURRENT AMENDMENTS. STORMWATER Stormwater drainage is to comply with AS/NZS 3500.3.2 and 3.1.2 of the BCA. Generally storm water run-off is to be disposed
THESE DRAWINGS TO BE READ IN CONJUNCTION WITH ARCHITECTS SPECIFICATION. of on site. The position of any pipework shown is diagrammatic only, exact locations including discharge points should be
approved by the appropriate authority prior to commencement. Prior to back filling, photographic records of pipework shall be
SITE VERIFICATION BEFORE COMMENCING CONSTRUCTION, ALL DIMENSIONS, EXISTING LEVELS, FINISHED LEVELS AND ALL taken by the builder.
SITE SERVICES ARE TO BE VERIFIED.
ARCHITECTURAL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ANY ASSOCIATED CONSULTANTS UNDER CLASS TREATMENT AS 3660-2000 & BCA 3.1.3
DRAWINGS.
FLOOR WASTES TO ALL WET AREAS
FIRE HAZARD PROPERTIES ALL MATERIALS AND ASSEMBLIES MUST COMPLY WITH SPECIFICATION C1.10 & C1.10a OF THE BCA FOR
CLASS 1 BUILDINGS. WET AREAS AS 3740
EXTERNAL LOADBEARING WALLS U/SLAB VAPOUR BARRIER AS 2904
Less than 1.5m to fire source feature: 90/90/90
1.5m to less than 3mm & 3m plus: -/-/- TERMITE BARRIERS AS 3660.1
EXTERNAL LOADBEARING POSTS/COLUMNS
Less than 1.5m to fire source feature: 90/-/- GLAZING TO EXT AS 2047
1.5m to 3m & 3m plus: -/-/-
INTERNAL LOADBEARING WALLS: to comply with Specification 1.8 of BCA SOUND RATINGS Refer Part F5 of BCA and AS 1276.1 for Rw (Weighted Reduction Index for Airborne Sound).
INTERNAL LOADBEARING POSTS/COLUMNS: 60/-/- WALLS: to common areas - Rw 50 (not less then)
COMMON WALLS OR FIRE-WALLS: 90/90/90 SERVICES: ducts for waste or water supply pipes that pass through one or more units to have Rw 40 if adjacent to habitable
FLOORS: -/-/- room (other than Kitchen) or Rw 25 if Kitchen or non-habitable room.
ROOF: -/-/-
EXTERNAL FIXINGS AND TO BE NON-COMBUSTIBLE AND CORROSION-RESISTANT
SMOKE DETECTOR SYSTEM TO AUSTRALIAN STANDARDS & BCA REQUIREMENTS LOCATED BETWEEN KITCHEN FITTINGS
AND BEDROOMS AS PER 1670.
PLUMBING AND ACCESS ALL PLUMBING DUCTS TO HAVE ACCESS PANELS TO COUNCIL REQUIREMENTS & HAVE REQUIRED SOUND
WATER SERVICE SUSTAINABILITY: PANELS RATINGS IF ADJACENT TO HABITABLE ROOMS OR COMMON AREAS
WATER-SAVING DEVICES: Group 7: 70kL per year required.
In accordance with PART 25 of the Queensland Development Code. HANDRAILS HANDRAILING AND BALUSTRADING TO COMPLY WITH PARTS D2.16 AND D2.17 OF BCA
In accordance with Part 29 of QDC & Water Act 2000, water saving shower roses must be used as a minimum. Use water
and energy saving devices through out. POOL FENCING AS 1926
Toilet Cisterns to have Dual Flush Capability not exceeding 6L on full flush & 3L on half flush.
SECURITY SELECTED BY OWNER, REFER MANUFACTURERS RECOMMENDATIONS
Hot Water System: 5 Star Rated Gas Instant System. Two Bottle Supply.
ELECTRICAL Energy Efficient Lighting: 80% of floor area to be fluorescent lighting. Compact Fluoro Lights (CFL) or LED's
RAINWATER TANK(S) 2 of 26,000 L (52,000L total). Selected to manufacturers installation.
ISSUE AMENDMENTS DRAWN JCH
- COPYRIGHT - These drawings to be A Working Drawings 10/04/2015
CLIENT Carter
used only with Architects written 23/04/2015 DATE 08/05/2015
consent. 28/04/2015
SCALE
08/05/2015
- DO NOT SCALE OFF DRAWINGS. PROJECT NEW Residence
LOT 17 Noosa Dunes, Castaways Beach NO. 1503
- Refer any discrepancies to Architect.
ROBINSON
ROBINSON ARCHITECTS
67 MEMORIAL DRIVE,
- Verify all dimensions on site.
DRAWING WD002 - General Notes
EUMUNDI QLD 4562
A RC HIT ECT S Ph. (07) 5442 8566
www.robinsonarchitects.com.au
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.