                                                                     BROWN CONSULTING (QLD) PTY LTD – SUNSHINE COAST



Specific Outcomes                      Probable Solutions                     Proposed Measures
                                       (if code assessable)
O3 In commercial zoned areas,          S3.1 Design of multi-tenanted          Not Applicable
the number of driveways                developments in commercial
across pedestrian footpaths is         zoned areas include shared
minimised.                             driveways and parking areas;
                                       AND

                                       S3.2 Driveways are located so
                                       they abut existing driveways or
                                       adjoining development where
                                       practicable and reciprocal
                                       easements are created to reduce
                                       the sealed driveway width.

O4 Vehicular access does not           S4.1 Footpath and kerb crossings       All vehicular access will take into
adversely impact on the                are located clear of existing          consideration associated
capacity, operations and               stormwater inlet structures, water     infrastructure and landscape
maintenance of the existing            and sewerage infrastructure            during the detailed design
infrastructure;                        fittings, any other exiting utility    process.
                                       infrastructure, existing
AND
                                       landscaping and vegetation.

O5 Vehicular access does not           S5.1 No solution provided.
adversely impact on the
integrity of existing
landscaping or native
vegetation.

O6 Driveway run-off is filtered        S6.1 For:                              The application includes a
prior to leaving the premises.                                                stormwater management plan for
                                       (a) Ancillary dwelling unit,
                                                                              quality, quantity and re-use.
                                           Multiple Housing Types 1 or
                                           2 if less than 5 carparking
                                           spaces, Visitor
                                           accommodation Type 1 and
                                           Home based business – the
                                           driveway is formed to drain to
                                           landscaped areas; and
                                       (b) For other uses – grease and
                                           oil arrestors or stormwater
                                           quality improvement devices
                                           are incorporated into the
                                           design to treat run-off prior to
                                           run-off exiting from the
                                           premises.


14.131 Service Stations
Specific Outcomes                      Probable Solutions                     Proposed Measures
                                       (if code assessable)
O7      The layout of the site         S7.1 Where the site is situated at     Not applicable
facilities    and     vehicular        the intersection of two roads,
accesses result in unrestricted        separate entrances and exits are
vehicle access and egress to           provided to one or more of the
the site.                              adjoining roads.




DEVELOPMENT APPLICATION (MCU): RSL CARE, TRADING POST ROAD, COOROY                                          PAGE    4

Used in these records

About this file

File size
354 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Engineering report [As Published].pdf · 354 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.