The proposal does not meet acceptable solution $1.3 due to the front setback encroachment. It is
considered however that the proposal meets the above performance criteria based on the following:

> The proposal maintains the visual continuity and pattems of buildings within the street.
The streetscape is characterised by buildings constructed to front boundary lines
including the two adjoining dwellings (see attached Context Plan).

> Vegetation within the road reserve will be retained and will serve to ameliorate the
impact of the front elevation on the streetscape.

> The constraints of the site, in particular the rear conservation zone, limit the design
options for development.

>  Plentiful landscaping will be provided as part of the development.

> The front setback encroachment will have minimal impact on the adjoining property
owners.

Acceptable Solution $8.1
With the exception of Ancillary Dwelling Units, the site cover of class 1 and class 10 buildings and other
roofed structures does not exceed 50% for a single storey building and 40% for a building of 2 storeys or
more.
Performance Criteria
08 The site cover of buildings and other roofed structures—
a) is of a scale that is compatible with surrounding development;
b) does not present an appearance of bulk to adjacent properties, roads or other areas in the
vicinity of the site;
c) maximises the retention of existing vegetation and allows for additional soft landscaping
between buildings;
d) allows for adequate area at ground level for outdoor recreation, entertainment, clothes drying
and other site facilities; and
e) facilitates on-site stormwater management and vehicular access.
SBR altemative provision to QDC Parts 11 and 12, P3

The proposal does not meet acceptable solution S8.1 as the proposed building is in excess of one storey
and site cover will be 48%. It is considered the proposal meets the above performance criteria based on
the following:

> The design of the facility incorporates a high level of articulation and avoids massing
issues which are a key component of limiting site coverage.

> The topography of the site means that a large proportion of the building mass is not
viewable from the street level. Likewise, the increased site coverage will not have a
discemable impact on the adjoining properties with the overall building length and height
comparable to the adjoining buildings (see context plan).

> Landscaping, including retention of existing shrubs at the front of the site, will help to
soften any potential massing issues.

Acceptable Solution $11.1

There is no acceptable solution for this criteria

Performance Criteria

O11 Where development does not comply with the built form acceptable solutions $1.1, $1.2, $1.3, S6.1

$8.1, $8.2 or S8.3—
a) buildings and other structures use lightweight materials and finishes that complement the
beachside character and integrate with the surrounding natural landscape and skyline
vegetation; and
b) views of building or structures from the beach are framed or filtered through vegetation (see
Figure 14-5).

 

MCU - Detached Dwelling Mike & Karen Rogers
15 Whale Drive, Sunshine Beach May 2007

Used in these records

About this file

File size
7.8 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

07_0786 - MCU - Detached House [As Published].pdf · 7.8 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.