Council archive · source document
Generally in Accordance Plan - MCU21 0222.01 (As Published) · MCU21/0222.01
Plans and drawings: the text below has words only, no drawings.
APPROVED WITH CONDITIONS
This is an Approved Building Works Document. Refer
to the Decision Notice for conditions of approval
1 2 3 4 PERMIT No. 35484
DATE 09/11/2023
BOUNDARY
8m HEIGHT LIM ISSUED BY COASTAL BUILDING
IT FROM DETAIL CONCRETE BEAMS TO ENGINEERS DESIGN AND
SURVEY
CERTIFICATIONS
DETAIL (TED) PTY LTD
CONCRETE ROOF - ENSURE
BOUNDARY
MIN. 1:100 FALL IS ACHIEVED
UPPER FLOOR PP RL 26030 UPPER FLOOR PP RL 26030
50
PLANTER - ENSURE SUFFICIENT
DRAINAGE. TO HYDRAULIC ENGINEERS CONCRETE BLOCK FEATURE COLUMNS TO
2700
DESIGN AND DETAIL ENGINEERS DESIGN AND DETAIL (TED)
2500
2500
W15
CONCRETE PLANTER BEAMS TO ENGINEERS KITCHEN DINING LIVING PLANTER - ENSURE SUFFICIENT
DESIGN AND DETAIL (TED) DRAINAGE. TO HYDRAULIC ENGINEERS
UPPER FLOOR RL 23530 DESIGN AND DETAIL UPPER FLOOR RL 23530
250
300
300
GROUND FLOOR PP RL 23230 GROUND FLOOR PP RL 23230
300
W5
ALL SUSPENDED SLABS TO ENGINEES DESIGN
3000
3000
AND DETAIL (TED)
2750
D10
70mm GARAGE STAIRS BED 2
GROUND FLOOR RL 20230 GROUND FLOOR RL 20230
RL 20160 RL 20230
300
780 300
300
LOWER FLOOR PP RL 19930 LOWER FLOOR PP RL 19930
EXISTING GROU
ND LINE FROM
ENSURE WATERPROOFING TO WALLS IN DETAIL SURVE
Y
ACCORDANCE WITH MANUFACTURERS
STANDARDS AND COMPLY WITH ASA AND BSA ALL RETAINING WALLS TO ENGINEERS
3480
3480
DESIGN AND DETAIL (TED)
2600
TERMITE BARRIERS TO BCA 3.1.3 200UM
WATERPROOF MEMBRANE TREATMENT AGAINST
GYM STAIRS STORE
TERMITE ATTACK (TERMIMESH OR SIMILAR)
LOWER FLOOR RL 16450 LOWER FLOOR RL 16450
RL 16450
SECTION 5
SCALE: 1 : 100
1 2 3 4
CONCRETE ROOF TO ENGINEERS DESIGN AND DETAIL PLANTER - ENSURE SUFFICIENT
(TED). APPLY WATERPRROFING OVER - WATERPROOF DRAINAGE. TO HYDRAULIC ENGINEERS
BOUNDARY
MEMBRANE TO BE 'DURAM 195 WATERPROOFING RL 26580 8m HEIGHT LIMIT FROM DETAIL DESIGN AND DETAIL
SURVEY
MEMBRANE'. WHERE EXPOSED TO ELEMENTS, THE CONCRETE ROOF - ENSURE
MEMBRANE IS TO BE TOPPED WITH 'MULTITHANE ATC'. MIN. 1:100 FALL IS ACHIEVED
UPPER FLOOR PP RL 26030 UPPER FLOOR PP RL 26030
BOUNDARY
50
SUSPENDED SLABS TO ENGINEERS DESIGN AND
2500
2500
2450
DETAIL (TED) W16
GLASS BALUSTRADE ON STAND OFF PINS TO
OUTDOOR KITCHEN DINING LIVING SPEC - ENSURE FINISHED HEIGHT IS MIN.
ENTERTAINING 1000mm ABOVE FINISHED FLOOR LEVEL
UPPER FLOOR RL 23530 UPPER FLOOR RL 23530
250
250
300
300
GROUND FLOOR PP RL 23230 GROUND FLOOR PP RL 23230
1380
300
W7 ALUMINIUM WINDOWS AND
DOORS TO SPEC
3000
3000
2750
BED 3
HIS/HERS
2400
ALL CONCRETE BEAMS TO ENGINEERS DESIGN AND
GROUND FLOOR RL 20230 DETAIL (TED) GROUND FLOOR RL 20230
300
780 300
300
VOID
LOWER FLOOR PP RL 19930 RL 18455 LOWER FLOOR PP RL 19930
50 300
EXISTING GROUND LINE FROM W2
DETAIL SURVEY
3480
3480
ALL RETAINING WALLS TO ENGINEERS DESIGN AND
DETAIL (TED)
2700
2700
PLANTER - ENSURE SUFFICIENT
ICE/ SAUNA SPA DRAINAGE. TO HYDRAULIC ENGINEERS
GUEST DESIGN AND DETAIL
STORE
LOWER FLOOR RL 16450 LOWER FLOOR RL 16450
0.5
TERMITE BARRIERS TO BCA 3.1.3 200UM
WATERPROOF MEMBRANE TREATMENT AGAINST
TERMITE ATTACK (TERMIMESH OR SIMILAR)
NOOSA COUNCIL
GENERALLY IN ACCORDANCE SECTION 6
MCU21/0222.01 23 SEP 2025 SCALE: 1 : 100
CLIENT: Maxine Horne PROJECT: BEACHES
www.chriscloutdesign.com.au GENERAL NOTES:
Use written dimensions only. DO NOT scale drawings. Contractors SITE ADDRESS: BEACHES NOOSA 7/56 David Low Way, SUNRISE BEACH QLD 4567
A: OFFICE 1/20 DUKE STREET, to verify all dimensions on site prior to commencing works. Site
SUNSHINE BEACH, QLD 4567, location in accordance with engineers details. These drawings are to DRAWING TITLE: SECTIONS
be read in conjunction with engineers design and details, the
E: [email protected] DATE: 31-08-23 SCALE: 1 : 100 @ A2 DRAWN BY: C.CLOUT
P: (07) 54748 107 BSA LICENCE: 1127508
accompanying building specification and schedule of finishes. If in
doubt, please request clarification. DO NOT ASSUME. ISSUE: PRELIMINARY WORKING DRAWINGS
W3.2
Document Set ID: 24127798
Version: 1, Version Date: 18/09/2025
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Generally in Accordance Plan - MCU21 0222.01 (As Published).pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.4 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.