                                                                R                                                                         1                                                                                            2                       3   F                                           BE
                                                                                    Concrete Tile
                                                                                    Roof Painted
                                                                                    in Colorbond
                                                                                    Basalt




                                                    Colorbond                            Skylight                           Skylight
                                                    Fascia
                                                                                                                                                                                                                                                                       Colorbond
Upper Level Ceiling Ht                                                                                                                                                                                                                                                 Fascia


41985


                                   Ceiling Height
                            2400

Upper FFL
39585
                                                                                                                                                                                                                                                                                                                     Ventura
                            185




                                                                                                                                                                                                                                                                                                                     Drive

Lower Level Ceiling Ht
                                   Ceiling Height
                            2400




39400
                                                                                                                                                                                                                                                                                                                     Letter Box to
                                                                                                                                                                                                                                                                                                                     Client Selection
                                                                                                                                                                                                                                                                                                                     & Body Corp.
Lower FFL                                                                                                                                                                                                                                                                                                            Approval

37000




        Proposed South Elevation
1        1 : 100                                                                                                                            BN                        A                                                                                                              BS
                                                                                                                                                                                 Aluminium Batten                   Weatherboard
                                                                                                                                                                                 Screening (White)                  Cladding




                                                                                                                                                                                         Skylight

                                                                                                                                                                                                                                       Box Gutter & Rainhead
                                                                                                                                                                             Skylight                            Skylight
                                                                                                                                                                 5°                                                                    To Engineer's Design
                                                                                                                                                             22 .
                                                                Upper Level Ceiling Ht
                                                                41985
                                                                                                           Ceiling Height
                                                                                                    2400




                                                                Upper FFL
                                                                39585
                                                                                                    185




                                                                Lower Level Ceiling Ht
                                                                                                           Ceiling Height




                                                                                                                                                      SHR
                                                                                                    2400




                                                                39400


                                                                Lower FFL
                                                                37000                                                                                                                                Pool Pump
                                                                                                                                                                                                     & Filter



        Proposed West Elevation
2        1 : 100



                          JMF DESIGN                                CLIENT:                                                            LOCATION:                      Project number                                                                                    NO:        DATE:        AMENDMENTS:
                          27 Sunhine Beach Road                     Sasha Dettori & Tony Caruso                                                                       Ventura 2022        Proposed Elevations
                          Noosa Heads Q 4567                                                                                           1/11 Ventura Drive,                                                                                                                         01/02/2022    Concept Plans
                                                                                                                                                                                                                                                                         26
                                                                                                                                       Sunrise Beach Qld                                                                                                                           24/02/2022    Client Amendments
                         e: [email protected]                   PROJECT:                                                                                          Date                Scale                             Drawn by            JG
                                                                                                                                       4567                                                                                                                                        03/03/2022    Client Amendments
                         www.jmfdesign.com.au
                                                                    Townhouse Renovation                                                                              May 2022                                                                                                     13/05/2022    Final Issue
                                                                                                                                                                                                      1 : 100               Checked by          JMF
                         QBCC 15200440
Log in to download the original file

2022.05.13_Unit 1_11 Ventura Drive_Sunrise Beach_DETTORI & CARUSO_Townhouse Renovation_Final Issue.pdf · 31.3 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.