NOOSA COUNCIL IDAS Development Application Decision Notice 3 of 6
Noosa Council Conditions
INTEGRATED PLANNING ACT 1997, IDAS DEVELOPMENT APPLICATION
1. Development undertaken in accordance with this approval must generally comply with the approved plans
of development. The approved plans are titled and numbered:
Site/Roof Plan, WD 1
Ground Floor Plan, WD 2
Level 1 Plan, WD 3
Section A, WD 4
Sections B & C, WD 5
Section D, Garage Elevations, WD 6
Elevations, WD 7
Elevations, WD 8
prepared by K R Architects and dated 10 January 2006 and as may be amended by these conditions.
2. The development must be undertaken and operated in a manner that causes no detrimental effect upon
the amenity of the neighbourhood by reason of the creation of excessive noise, lighting nuisance or other
emissions.
3. All hot water systems installed shall be either solar systems; electric heat pump systems; or gas systems
(LPG or natural).
4. A rainwater storage tank with a minimum capacity of 5000 litres shall be provided on site to service the
detached house. The tank is to be installed to ensure water from the tank can be used both:
4.1. for external use such as watering gardens, irrigation, ornamental ponds or water features, topping
up swimming pools, outdoor cleaning; and
4.2. for use in flushing of toilets internal to the building.
5. Buildings and structures (including swimming pools, sheds, tennis courts or outbuildings) are not
constructed under overhead electricity transmission lines, or within any easements.
6. All buildings proposed on site shall be constructed to comply with Council’s Minimum Floor Height
requirements as defined in Council’s Planning Scheme and on Council’s Scheme Maps at the time of
issue of the Building Permit.
7. The area within 4.5 metres of the revetment wall shall meet the following requirements:
a) a minimum of 25% of the area is planted with shrubs; and
b) a maximum of 25% of the area is under hard pavement and the balance is to be turf or ground
covers; and
c) No tree species with a mature height of over 3m are to be planted; and
d) No shrubs are to be planted within 1m of the revetment wall; and
e) The ground surface within the first metre from the revetment wall is turf, ground cover or hard
pavement.
8. The Development Permit for a material change of use lapses if the use has not happened by 23 April
2011, unless an application to extend the currency is approved by Council.
A c:\docume~1\dlsmith\locals~1\temp\bcl technologies\easypdf 5\@bcl@d0077ec4\@[email protected]
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Decision Notice - 010.2007.00000339.001 [As Published]Related documentApplication case desk ↗
About this file
- File size
- 34 KB (small file)
- File type
No other editions are linked here.