Council archive · source document
planning report 98 Hilton · MCU26/0078
4.0 Planning assessment
Some of the key parameters are provided in Table 3 below, with further assessment provided
thereafter.
Table 3: Summary of development aspects and compliance with the Codes
Criteria Noosa Plan 2020 Proposal Compliance
MDR and Dwelling House Codes
Site Details 2,484m² – Medium Density Residential
Zone
Height (AO3) 8m 8.75m PO
2 storeys 2 storeys Y
Site Cover (AO10) 40% - 993.7m² 34.3% - 854m² Y – see snip below
39.7% - 987m² (Including pool and spa area Y – 130m² of pool area
1m above NGL)
Gross floor area 0.4:1 – 993.6m² 0.36:1 – 891m² Y
(AO11)
Setbacks (AO12) Frontage (6m) 9.2m Y
west side (1.5m / 2m) 3.8m - ground Y
2.5m – upper roof
east side (1.5m / 2m / 2.5m >7.5m) 1.5m - ground Y
2.5 – upper roof
Rear (10m from MHWS) 10m to structure/pool>1m in height Y
Building design N/A - The house is unlikely to be seen from Y – visual interest Y
(AO14.5) the street given the existing mature
vegetation. The side of the garage
is obscured by the fence and boundary
angle. The porte-cochere has feature
landscaping which provides visual interest
while being significantly further
setback than the garage.
Garage (AO15) No garage faces the street. The side of the Y Y
garage faces the street, however is
setback more than 9m form the boundary
with a significant 5m dense landscaped
buffer.
Roof Form (AO19) No roof top terrace Y – The top of the roof is pitched Y
Parapet walls do not exceed 50% of the
façade
5 degree pitch and eaves to >75% of
building.
Front fencing Fencing setback >1m or 1.2m / The western side of the driveway is on the Y
(AO17) 50%transparent if on boundary boundary and is a maximum of 1.2m in
height. Y
The eastern side includes an
avg 1m setback
Landscaping (AO6) 20% soft landscaping (496m²) 35.7% (886m2) Y
Carparking and 2 covered and driveway design criteria 6 covered spaces Y
access (AO7-14)
Flood Hazard Area 300mm above DFE 2.7m AHD Y – in accordance with flood search
(AO16)
Acid Sulfate Soils Overlay Code
Avoidance and Acid sulfate soils reporting and Not undertaken Y – required to determine if
Management of management fill quantity exceeds 500m³ (under
ASS (AO1) slab and footings) – Able to
be complied with and reporting
included with application.
Flood Hazard Overlay Code
Flooding (AO1- 1%AEP flood immunity + 300mm free Minimum floor heights are achieved. Y
AO11) board . Minimal fill to reduce flood risk
Page 6 of 9
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
planning report 98 Hilton.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.0 MB (small file)
- File type
No other editions are linked here.