Original source · versioned page text
Amended Proposal Plans p10-19
The original of this document is very large (17.6 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Original PDF page 4, section 1. The text section number identifies this passage in the reader.
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn EXT. FINISHES LEGEND
AFD aluminium framed door.
AFW aluminium framed window.
AL aluminium louvres, refer sched.
AS aluminium screen.
ASD aluminium sliding door.
BAL balustrade
BLK masonry blockwork.
I H G F E D C B A C carpet
conc reinf. concrete wall/pool shell
3,500 7,190 1,690 7,820 9,940 1,000 6,550 10,300
CS concrete slab.
FCA fibre cement awning.
FC fibre cement cladding
FG fascia gutter.
FT1 floor tile - (no refers to type).
flue
fire fireplace
flue flue kit
HH 'Heka' hood, ref sched.
flue flue join joinery item, by joiner
FFL 159.080 FFL 159.080
HOUSE ROOF HOUSE ROOF
MR1 metal roof - (no refers to type).
PB plasterboard lining, ref. sched.
DECK
FORMAL LIVING COVERED FAMILY PF compliant pool fencing
LOUNGE
KITCHEN FOYER DINING POOL PW parapet wall.
HOUSE REN polymer render
FFL 156.300 pizza
FFL 156.300
SBJ silicone butt jointed glass.
HOUSE MAIN LEVEL HOUSE MAIN LEVEL SP structural post, refer engineer.
COVERED SPA
STR1 stair (no. refers type)
LOUNGE
POOL EN SUITE BED 5 POOL TIM timber cladding, ref. schedule
BED DRESSING STAIR BED 5 TD timber deck.
TERRACE TF timber floor.
FFL 153.600 FFL 153.600 TS timber screen, ref. detail
HOUSE LOWER LEVEL HOUSE LOWER LEVEL
VER vergola.
WC
PLANTER VJ1 vertical joint lining, ref sched.
(no. ref. type).
STAIR GYM BAR GAMES CINEMA STAIR
TENNIS COURT
seat seat seat
NORTH ELEVATION (tennis court)
SCALE 1:100 @ A3
I H G F E D C B A
3,500 7,190 1,690 7,820 9,940 1,000 6,550 10,300
WALL LEGEND
RC masonry blockwork
RC pool shell/off form concrete
90MM ext. timber frame
flue
70MM int. timber frame
Indicates extent of
chs shs structural posts - refer
engineer.
flue
FFL 159.080 FFL 159.080 GENERAL LEGEND
HOUSE ROOF HOUSE ROOF D04 denotes door number
DECK W04 denotes window number
FORMAL LIVING FAMILY
RL 17.200 denotes finished floor level
KITCHEN FOYER DINING POOL + RL 17.700 denotes spot level
HOUSE 50 step denotes change in level
COVERED pizza
FFL 156.300 FFL 156.300 fw
LOUNGE denotes floor waste
HOUSE MAIN LEVEL HOUSE MAIN LEVEL
SPA denotes hard wired smoke
alarm BCA 3.7.2 min
300mm from wall
POOL EN SUITE BED 5 POOL 5deg denotes direction of roof fall
BED DRESSING STAIR BED 5
metal denotes roof material
TERRACE
FFL 153.600
HOUSE LOWER LEVEL
SPA
FFL 153.600
HOUSE LOWER LEVEL FLOOR FINISH LEGEND
WC FT1 FT2 Indicates extent of TILE
STAIR GYM BAR GAMES CINEMA STAIR C Indicates extent of CARPET
PLANTER PLANTER
TF TD Indicates extent of TIMBER.
seat seat
GS DR Indicates extent CONCRETE
FINISH CODE LEGEND
NORTH ELEVATION denotes additional 'extent' information
SCALE 1:100 @ A3 (xxxxxxxx)
XX
denotes finish, refer 1000
series drawings for schedule
denotes item and number.
JXX refer to Joiner for details
PROPOSAL ONLY (pending local authority approval)
© Aboda Design Group NOT FOR CONSTRUCTION
DA(2) For Development Approval (2)
issue issue / amendment
08.08.22 SF JH AB
issue date drawn by
client
J & C Blake
project
Blakes Farm
location
42 Lukes Rd Coory Mountain
ELEVATIONS
Aboda Lee Foster • director Scott Falconer • director
Design p - 0424 620 247 p - 0431 267 157
Group e - [email protected] e - [email protected]
the aboda design group trust Level 2 1794 David Low Way Coolum Beach,
ABN 56 266 884 746 Q. 4573. PO box 2449 Noosa Heads Q 4567
t/a aboda design group • BSA License -150580097 • www.aboda.com.au
• This drawing is to be read in conjunction with engineers drawings & reports • Construction
to comply with all relevant SAA & NCC Codes & standard Bldg By-law 1975 & as amended •
Copyright for design & drawings remain the property of the authors • Verify all dimensions on
site prior to commencement of any works • These drawings are not to be used for scaling.
scale as noted at A1 issue
drawing no.
WD.502 DA(2)
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.