Project No. 306-2474
  November, 2006                                                                         Page 3
    4.3   Laboratory Testing
       Laboratory testing was carried out on representative samples of the subsurface material
       obtained during the field investigation to assess the geotechnical properties.
       Laboratory testing included:-
        *   Particle Size Distribution - to assess the percentage by mass of particles within
           different size ranges.
       All laboratory testing was conducted in accordance with Australian Standards methods.
       The results of the laboratory testing are summarised below (Table 1), and provided in full
       in Appendix C.
      TABLE 1           LABORATORY TEST RESULTS                                                  ©
                   BH1                          0.65m                 Passing 0.6mm = 99%
                                                                      Passing 0.3mm = 68%
                                                                     Passing 0.075mm = 3%

5.0   GEOTECHNICAL MODEL
   5.1   Subsurface Profile
      The subsurface profile encountered in the boreholes generally consisted of fine to
      medium grained silty sand. Fill material was encountered in both of the boreholes drilled
     using the 4WD mounted Jacro 200 drilling rig. The fill material encountered in borehole     @
     BH1   consisted of very dense sandy gravel associated with the existing driveway
     construction, in which the borehole was located at. The fill material encountered in BH2
     consisted of loose silty sand to a depth of approximately 1.0m. The natural subsurface
     materials encountered in the boreholes consisted of typically of dense and very dense
     silly sand with layers of loose to medium dense sands.
     Groundwater was not encountered in the boreholes at the time of the investigation.
     Seepage should be expected through the granular materials following periods of
     prolonged rainfall.

                                                         BH SOIL SURVEYS ENGINEERING
                                                        ~

Used in these records

About this file

File size
4.1 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

0015584F.001.pdf · 4.1 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.