Original source · versioned page text
Decison package_Noosa Chocolate Factory
Attached to the e-mail MCU16/0098 & OPW16/0183 - Request to change existing approval - 21 Venture Drive NOOSAVILLE.
Original PDF page 4, section 1. The text section number identifies this passage in the reader.
Noosa Council documents
MCU16/0098
Table 1
NOISE LIMITS AT A SENSITIVE RECEPTOR
(Excludes On-Site Ancillary Dwelling Unit – Caretakers Unit)
PERIOD Noise level at noise sensitive place measured as the
adjusted maximum sound pressure level (Lamax, adj,T)
7am – 6pm Background noise level (LAbg,T) plus 5 dB(A)
6pm – 10pm Background noise level plus 5 dB(A)
10pm – 7am Inaudible
NOISE LEVELS AT COMMERCIAL PLACE
PERIOD Noise level at a commercial place measured as the adjusted
maximum sound pressure level (Lamax, adj,T)
7am – 6pm Background noise level (LAbg,T) plus 10 dB(A)
6pm – 10pm Background noise level plus10 dB(A)
10pm – 7am Background noise level plus 8 dB(A)
22. When requested by Noosa Council, a Noise Impact Assessment Report (NIAR)
showing monitoring and recording of noise levels must be undertaken to
investigate any non-vexatious complaint caused by noise emissions from
operations at the premises. Such monitoring must be undertaken and completed
within a reasonable and practicable timeframe as nominated by council and be
performed by a suitably qualified and experienced person.
The NIAR must be submitted to Council detailing the results of such monitoring
and recommendations for any measures to achieve compliance with limits outlined
in Table 1 of this Decision Notice.
23. Measurement of sound pressure levels (adjusted for tonality and impulse) must be
in accordance with Australian Standard AS1055.1 “Acoustics – Description and
measurement of environmental noise – General procedures”.
For the purpose of measuring and certifying relevant noise conditions and
reporting (eg. mechanical plant and equipment, a/c units, motors, refrigeration
equipment, compressors, pumps etc ), a suitably qualified person is either:
a. a Registered Professional Engineer of Queensland, or
b. an environmental consultant with a minimum of 3 years current experience in
the field of acoustics.
Outdoor Lighting Devices
24. Lighting associated with the use must be designed, sited, installed and tested to
comply with Table 2.1 & 2.2 of Australian Standard AS4282-1997 “Control of the
obtrusive effects of outdoor lighting” using a control level of 1.
Page 4 of 18
Document Set ID: 20204040
Version: 1, Version Date: 22/11/2016 Print Date: 22 November 2016, 1:58 PM
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.