Original PDF page 57, section 1. The text section number identifies this passage in the reader.
Page 8 of 13 6.4 Foundations The subsurface conditions encountered in the bores typically comprised relatively loose to medium dense sand fill, overlying typically medium dense to dense natural sand. At basement level, high level footings are expected to be founding into medium dense or better sand. High level footings may be designed using the allowable bearing pressures given in Table 4. Table 4: Allowable Bearing Pressures for High Level Footings Material Allowable Bearing Pressure (kPa) Existing uncontrolled fill 75 Medium dense (or better) natural sand 100 The above bearing pressures are contingent upon all footing excavations being free of any loose material prior to the placement of concrete. All footing excavations should be inspected and tested by an experienced geotechnical engineer from Douglas to confirm bearing capacity prior to casting of concrete. Experience indicates that properly designed and constructed high level footings sized using the above allowable bearing pressures are likely to undergo settlements in the order of 1% of the footing width. Further advice should be sought from Douglas regarding settlements once actual footing configurations and design loads are known. Slabs supported on high level footings should be stiffened to suit the expected ground surface movements. Where footings are located adjacent to underground services, the footings should extend to below invert level for a distance of 1 m out from the trench. Beyond 1 m from the trench, the footings should be taken to below an imaginary line drawn up at 45 degrees from the invert level. These requirements do not override minimum structural footing base levels. Where necessary, footings may be made up with mass concrete poured to the underside of footing, or alternatively constructed over excavated pedestals. Alternatively, where development loads exceed the above allowable bearing pressure and estimated settlements, a suitable deep foundation will be required. Screw piles would be considered suitable given the subsurface conditions encountered. The ultimate, unfactored end bearing values given in Table 5 will need to be multiplied by a suitable geotechnical strength reduction factor (Øg) to obtain the design geotechnical strength (Rd,g) of piles. In accordance with AS2159 (2009), the Øg value must be determined by the designer, but based on the anticipated site, design and installation risk factors, a Ø g value of at least 0.45 is considered likely for a low redundancy pile system. Proposed Residence 229073.00.R.001.Rev0 13 Mermaid Quay, Noosaville June 2024
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.