07/0616 - Response to Information Request [As Published] · 132007.616
DRAWING SIZE - A3
NORTH
aa —- ne
>
a
<x
S
=
3
ao
Qa.
a
LEGEND
INDICATES APPROXIMATE
EXCAVATION DEPTHS
300Sq PIPE JUNCTION BOX,
PRE-CAST CONCRETE.
SPRAYED RC FACING TO
SOIL RETENTION VIA
CONTIGUOUS CONCRETE PILED
RETAINING WALL BY
EXCAVATED FACE TO DETAIL SPECIALIST CONTRACTOR
CUTOFF DRAIN
RP BOUNDARY
INDICATES APPROXIMATE
EXCAVATION DEPTHS
*3.20m _|
PROPOSED BUILDING FOOTPRINT
RP BOUNDARY
SOIL RETENTION VIA
CONTIGUOUS CONCRETE PILED
RETAINING WALL BY
SPECIALIST CONTRACTOR
SITE _PLAN
SCALE 1:200
TYPICAL SECTION ~ CUT OFF DRAIN
RP BOUNDARY
EDGE OF ROAD
ATTUNGA HEIGHTS
SPRAYED 25MPo CONCRETE
FACING SL72 MESH MIDDLE
Ercavated| Level
Description
CONSTRU NOTES
GENERAL:
1. Do not scale from this drawing.
2. All dimensions in millimetres
3. Setting out dimensions are to be obtoined from the architectural drawings.
4. Any idiscreponcies between these drowing ond the architectural drawings are to be
referred to the engineer immediately.
5. The buider i is responsible for locating all existing services within and adjacent the
allotment and sholl ensure that all new works are in accordance with the attached
critical ;depth line diagram.
FOOTPATHS AND DRIVEWAYS:
1. Existing footpaths to be sow cut prior to removal
2. Crossings are not designed for commercial vehicles
3. Concrete driveway to be 125mm thk. excluding ony finished treatments, eg.
stomping
4. Concrete surface tolerance +5,0mm over 3.0m
5. Concrete N25 in accordance with AS 1379 and AS 3600
6. Reinforcement fabric to AS 1304, placed central slab depth.
7. Expansion pints to be 10mm wide wet tooled with every 2nd mesh wire cut along
joint. |
8. One laccess point permitted for each allotment.
9. For curved driveways, maximum grades apply to inside edge of curve
10. All Korvces to be located and protected as required prior to work commencing
FILLING NOTES:
The site is to be scraped clear of all organic material and debris.
— The subgrade i is to be proof rolled with o vibrating steel drum roller to achieve a
minimum relative field density of 95% The compaction is to be sufficient to achieve
a blow'count of 7 blows per 300mm with an approved Perth Sand Penetrometer for
0 depth of 1.0m below excavated level. Copies of compaction test results shall be
presented to SCG Consulting Engineers for approval,
- Upon the written approval of the subgrade preperations by SCG Consulting
Engineers
the allotment is to be filled to the specified levels.
= The fill material clean granular material (ie. sand to a clayey sand in accordance
with ASI726) be free of any organic material and have o clay content of less than
12% (Plasticity Index less than 25%, Linear shrinkage of 15%). The proposed moterial
is to be inspected by SCG Consulting Engineers prior to its removal to ensure its
compatability.
~ The fill is to be placed and compacted in accordance with AS3798-1996 to a _
level sufficient to achieve o Level 1 certification with a minimum relative field density
of 95% Copies of compaction test results shall be presented to SCG Consulting
Engineers for approval.
- Filing and compacting adjacent exisiting structures is to be in strict accordance
with the associoted details and specifcations.
- Areds where existing structures or trees ore removed shall be backfilled with the
approved fill material compacted in accordance with AS2870-1996 to achieve a
minimum relotive field density of 95%
- Anylloose or soft material uncovered in the site preparation shall be removed ond
replaced with the approved fill material compacted in accordance with AS2870-1996
to achieve a minimum relative field density of 95%
- Site| drainage and silt protection measures must be istalled prior to construction
commencing.
SOG sien Sa “paieteaa
ABN 40 098 481 899
{3 DUKE STREET SUNSHINE BEACH QLD.4567
ic (07) 5447 5544 Fax (07) 5447 2634
(Title: SITE PLAN.
Project 8 Attunga Heights
Noosa Heads
[bate: June 2007 Drg No. 17177-ST1
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/0616 - Response to Information Request [As Published]Related documentApplication case desk ↗
About this file
- File size
- 1.6 MB (small file)
- File type
No other editions are linked here.