PLANT SCHEDULE
TREES & PALMS
MINIMUM | MIN HEIGHT QTY [STKS/ CLPR] CLEAN
CODE BOTANICAL NAME POT SIZE_| AND SPREAD GUYS STEM
BAC cit BACKHOUSIA citriodora 2sitr 6 STKS
CUP ana CUPANIOPSIS anacardioides 45 ltr 1700x800mm 5S STKS|40mm]|1.6m
HAR pen HARPULLIA pendula 45ltr 1700x800mm 2 STKS|40mm
LIV aus LIVISTONIA australis 2m Clear Trunk _|2 STKS
XAN chr XANTHOSTEMON chrysanthus 46ltr 1700x800mm 5 STKS|40mm
HEDGING & FRUIT TREES
CODE DESCRIPTION
SIZE _HGT&SPRD QTY. STKS
CIT lat CITRINUS latifolia 25ltr 1
CIT MEY CITRINUS "Meyer Lemon" 25ltr 1
MET FF METROSIDEROS 'Fiji Fire" 200mm|_500x250mm | 30
SYZ RES SYZYGIUM 'Resilience" 200mm|_500x250mm |_76
SHRUBS
CODE DESCRIPTION
SIZE _HGT&SPRD QTY. STKS
ACM AM ACEMNA “Allyn Magic" 200mm|_450x250mm |_41
ALP cae ALPINIA caerulea 140mm|_250x150mm | _ 4
BLE car* BLECHNUM cartilaginum 140mm|_250x150mm | _12
CAL LJ CALLISTEMON "Little John" 200mm|_350x200mm |_ 24
(COR fru RUB|CORDYLINE fruticosa "Rubra" 200mm|_500x250mm |_25
COR str CORDYLINE stricta 200mm|_500x250mm | 5
CYA coo* _|CYATHEA cooperi I300mm| 2
CYC rev CYCAS revoluta I300mm| 3
DOR pal DORYANTHES palmeri 200mm|_350x200mm |_ 12
GRE HG GREVILLEA "Honey Gem" I200mm|_400x300mm |_7
GRE SU GREVILLEA "Superb" 200mm|_400x300mm | _7
ROS off ROSMARINUS officinalis 140mm] 250x150mm |_ 3
STR reg STRELITZIA reginae 200mm|_400x300mm |_ 6
SYZ TT SYZYGIUM "Tiny Trev' 200mm|_350x200mm |_ 9
WES fru WESTRINGIA fruticosa I200mm|_450x250mm |_27
ZAM fur ZAMIA furfuracea I300mm| 3
GROUNDCOVERS - GRASSES + CLIMBERS
CODE DESCRIPTION
SIZE _HGT&SPRD QTY. STKS |
DIA LJ DIANELLA caerulea "Little Jess" 140mm] 250x250mm |_ 48
HIB sca HIBBERTIA scandens 140mm] 150x150mm | 22
LIREG LIRIOPE “Evergreen Giant 200mm|_300x300mm |_ 82
LOM SH LOMANDRA 'Shara' 140mm) 150x150mm | 17
PHI XAN PHILODENDRON "Xanadu" 200mm|_150x200mm |_15
TRA jas TRACHELOSPERMUM jasminoides —_[140mm\|_150x300mm |_14
TUL vio TULBAGHIA violacea 140mm] 200x150mm | 24
ZOY ten ZOYSIA tenuifolia 140mm] 150x150mm | _ 35
Note:
* Sun-hardened stock required.
Plant numbers shown on plans are indicative and require final count once
the layouts are approved for construction.
Plant sizes stated are subject to availability at time of construction.
PLANTING
GROUNDCOVERS
LEGEND
EXTERNAL WORKS
GENERAL
EXTENT OF WORKS
DETAIL / SECTION REFERENCE
00 DETAIL / SECTION NUMBER
\gp-D-94 DRAWING No. CROSS REFERENCE
GRADING
+EX0.00 EXISTING SURFACE LEVEL
+0.00 RELATIVE LEVEL
Fall INDICATES DIRECTION OF
T100> DECLINING (DOWN) GRADIENT
FENCES
_ FEN-1 FENCE TYPE 1
—_/— - Refer to Detail 06 CD-200
FEN-2 FENCE TYPE 2
caeeeee - Refer to Schedule
FEN-3 FENCE TYPE 3
—=— _ -Refer to Schedule
FEN-4 FENCE TYPE 4
§ s - Refer to Schedule
WLT-1 WALL TYPE 1
e47774 — - Refer to Schedule
WLT-2 WALL TYPE 2
e227) _ Refer to Schedule
PAVEMENT FINISHES
° PAVEMENT TYPE 1
[PO1 - Refer to Schedule
PAVEMENT TYPE 2
PO2} - Refer to Schedule
PAVEMENT TYPE 3
- Refer to Schedule
PAVEMENT TYPE 4
- Refer to Schedule
a SHRUBS TURE
/ \ PLANTING AREA
\ TREE
| +)
\ — EDGE TYPE 1 :
\ wy, FA - Refer to Detail 04 CD-200
——__ EDGETYPE2—
E2 - Refer to Detail 05 CD-200
MULCHED TREE PITS
HC HOSE COCK —
oF - Refer to Architect
WATER
t—w—__ - Refer to Survey
COMMS
MATERIALS & FINISHES SCHEDULE ~ Refer to Survey
ITEM CODE REQUIREMENTS
Wall Type 1 WLT-1 1800mm high Rendered & painted masonry wall. Refer to Architect
Wall Type 2 WLT-2 Existing 2000mm high masonry block wall. To have new render and paint finish. Refer to Architect.
Fence Type 1 FEN-1 1800mm high Treated Hardwood/Treated Pine butt-joined timber paling fence. Refer to Detail sheet CD-200
Fence Type 2 FEN-2 1800mm high HWD horizontal batten timber fence and gates as shown. Refer to Architect.
Fence Type 3 FEN-3 Existing 1800mm high timber paling fence
Fence Type 4 FEN-4 1200mm high Semi-frameless glass pool fence.
Pavement Type 1 PO1 Concrete driveway with feature colour or exposed aggregate finish. To be confirmed - refer to Engineer.
Pavement Type 2 P02 Concrete footpath. To be plain grey with broom finish.
Pavement Type 3 P03 Concrete service/washing line areas. To be plain grey with broom finish.
Pavement Type 4 P04 Formed in-situ concrete steppers with feature gravel in between. Colour to be confirmed.
Timber Deck TD Manufactured recycled timber deck system - Modwood or similar approved.
Edge Type 1 E1 Extruded concrete edge. Refer to Detail Sheet CD-200.
Edge Type 2 E2 Timber edge. Refer to Detail Sheet CD-200
Turf Type 1 Turf to be A-grade 'Winter Green Couch.
GENERAL NOTES
1. FALLS
Grade all turf and planting areas evenly in the direction shown. Ponding is not
acceptable.
2. SOIL:
Where available maximise the use of soil from on site. However, whether from site or
imported, soil is to comply with AS 4419, soils for landscaping and garden use.
All soil shall be free from noxious weeds, rocks, roots, rubbish or any other deleterious
material.
3. WEED MANAGEMENT:
All weeds listed in the Land Protection (Pest and Stock Route Management) Act 2002
and sub-ordinate Regulation 2003, and the Maroochy Pest Mangement Plan 2006-2010
(pest species of significance in Group 1, Group 2, and Group 6) must be removed from
the site in a manner that minimises regrowth, prevents damage to non-target weed
species and retains indigenous vegetation and conservation values.
4, TURF AREAS:
All turf areas to fall towards drainage pits / collection / infiltration locations. Cultivate
existing sub-grade to 150mm depth, place topsoil to a depth of 150mm. Refer Material
and Finishes Schedule for turf type.
5. PAVEMENTS AND THRESHOLDS:
All vehicular pavements by Civil. All pedestrian pavements (by Civil or refer to Material
and Finishes Schedule). Landscape plans indicate finish / material type and decorative
saw cuts - Refer to Engineers drawings for all other details and extents.
6. PLANTING:
Refer drawings for locations:
Cultivate existing sub-grade to 150mm depth, place topsoil to a depth of 300mm, place
'Hoop Pine’ mulch 100mm deep. Mound to promote positive drainage as indicated on
detail. Refer to planting plan for typical coded plant layout. Refer to plant schedule for
plant species and codes.
7. TREE PLANTING LOCATION NOTES:
LOCATE TREES GENERALLY IN ACCORDANCE WITH LOCAL AUTHORITY
STANDARDS.
- Aminimum 2.0 metres from driveway cross over.
- Aminimum of 1.0 metre from all services to prevent root/service conflict and to provide
future ease of maintenance requirements.
- Aminimum of 2.0 metres from stormwater catchment pits.
-Aminimum of 4.0 metres from street lights.
-Aminimum of 1.0 metre from kerbs and pavement edges.
- Aminimum of 6.0 metres from electricity poles and pillars.
- Not within sewerage easements or other service infrastructure easements.
- Street trees must be located a minimum of 750mm behind the kerb. Street tree
locations subject to set out on site.
TREE REQUIREMENTS.
- Generally all trees shall have a minimum of 1.2 metre clear trunk unless otherwise
specified.
- Tree stocks 45ltr and above to have 2 hardwood stakes as per detail or unless
otherwise specified.
- All tree stock within the landscape works must comply with NATSPEC guidelines, refer
specification.
8. MOWING EDGES:
Refer Materials Schedule on CD-001 and to Details on CD-200.
9. FENCES:
All fences and footings to be located within private property. All in-ground timber to be
F17 H4. Where new fences are indicated on the drawings, existing fences are to be
demolished, unless otherwise noted. Refer Materials and Finishes Schedule for fence
types. Refer plans for locations and refer CD-200 for Details. Set out to be determined on
site with Landscape Superintendent.
10. SERVICES:
The location of all underground or overhead services services shown on these drawings
are indicative only. They have been incorporated at the design or Council approval stage
for general information. The Landscape Contractor shall be responsible for liaising with
the Head Contractor to determine the 'As constructed! location of all water, sewer,
stormwater, electrical, communication or other existing services before commencing any
excavation works.
11. DRAINAGE
Refer Civil Engineers drawings for main storm water drainage. Subsoil drainage lines and
field inlet gullies within landscape areas as shown on landscape drawings. Ensure
positive fall of subsoil pipe to stormwater pits / outlet.
12. HYDRAULICS:
Refer Hydraulic Engineers drawings for locations of all fire hydrants, hosecocks, water
meters and other water infrastructure. All to be coordinated prior to construction. 1
hosecock to be provided in each private courtyard.
13. SEDIMENT AND EROSION CONTROL:
Refer Civil Engineers drawings for all sediment and erosion control measures.
14. ESTABLISHMENT & MAINTENANCE:
All landscape works to include 12 weeks establishment (with exception of works
completed within the months of June / July where an additional 4 weeks establishment
period is required to ensure adequate establishment of stock). Maintenance and Defects
period to be 12 months on all trees (25It and over) and hardscape works.
GENERAL PLANTING NOTES
1, PLANT QUALITY
All plant stock is to be be to the scheduled nomenclature, well formed, hardened off
nursery stock. They are to be container grown in potting mixture with a healthy root
system and not pot bound. All pots shall be free of weeds and plant stock is to be free
from living insects, pests and disease. All plants are to be fully sun or shade
hardened-off to suit their on-site growing position for a minimum period of 6 weeks.
Ensure sufficient supply of each species shown on the drawings is available to achieve
the required layout and densities, and in the event of supply for replacement stock due
to failure, damage, unhealthy specimens or theft. Prior to plant stock arriving to site, a
nursery inspection including the Landscape Architect and Landscape Contractor is
required. The plant supplier is to ensure all stock (or good selection of stock) is present
during the inspection. It is also recommended that the Landscape Architect is on site to
inspect plant stock and plant set out prior to implementation.
2, IMPLEMENTATION
Ensure all planting procedures result in healthy plant species within the prevailing soil,
climatic and management environment of this project. The following minimum is
expected:
- Excavate a hole for each plant twice the diameter of the rootball and 100mm deeper
than the root ball. Break up the base of the hole to a further depth of 100mm and
loosen the sides of the hole.
- Remove the plant from the container with minimum disturbance to the root ball, place
in final position, ensure it is central and plumb. Ensure the root ball is level with the
finished surface of the soil surrounding the hole or bed.
- Ensure correct placement of fertiliser and/or water retention additive as per
manufacture's specification and requirements.
- Thoroughly water plants immediately after planting and at such times during the
contract period as required. All 45ltr, 300mm, 140mm & TS will require a minimum of
10ltrs of water at the time of planting.
- Backfill with topsoil as specified. Lightly tamp and water thoroughly to eliminate any
air pockets. Ensure that topsoil is not placed over the top of the rootball.
Refer to Details on CD-200 as reference.
Collect all empty plant containers daily during planting operations and remove from
site.
Do not vary the plant locations from those specified on the drawings unless otherwise
directed by the Superintendent. Should it be necessary to vary the locations and
spacing for any reason, immediately apply for directions by the Superintendent.
3. PLANT ESTABLISHMENT
The Establishment Period commences at the date of Practical Completion of Works.
During the Establishment Period maintain best horticultural practices, as well as
rectifying defects that become apparent in the works under normal use including (but
not limited to) the following items where required: watering, weeding, fertilising, pest
and disease control, mulching, pruning, rubbish removal and keeping the site neat and
tidy.
4, PLANT REPLACEMENT
Replace failed or damaged plants. This does not include vandalised or stolen plant
material - this will be replaced prior to practical completion.
5. SITE SOILS
All soils are to comply with AS 4419 Table 1 (both site topsoil and imported topsoil) and
receive appropriate amelioration if required. All topsoil must be free from noxious
weeds, rocks, roots, rubbish or any other deleterious material.
Place all topsoil in the areas directed and specified. Ensure that the topsoil is spread
and graded evenly to prevent any ponding. Prevent excess compaction by construction
plant. Stripped site topsoil needs to be stored in piles no greater than 2m high x 3m
wide. Topsoil storage piles for storage greater than 4 months should be seeded with a
suitable grass mix. Eradicate weeds using environmentally acceptable methods, such
as a non-residual glyphosate herbicide in any of its registered formulae, at the
manufacturer's recommended maximum rate. Noxious weeds need to be screened out
of the topsoil prior to placement.
6. MULCH
All mulch is to be free of deleterious or extraneous matter such as soil, weeds, rocks,
and twigs. The finish level of the mulch is to be level with the finish level of all adjacent
surfaces after settlement allowances of the topsoil and mulch. Ensure all mulch is
placed clear of plant stems to avoid rotting at ground level.
7. IRRIGATION
A irrigation system will comprise of a sub-surface dripper system. Refer to Hydraulic for
connection to potable or tank sources.
DRAWING SCHEDULE
COVER SHEET
EXTERNAL WORKS PLAN / PLANTING PLAN
CONSTRUCTION DETAILS
14073 CD-001
14073 CD-002
14073 CD-200
Note:
Refer Cover Sheet for legend.
A APPROVAL 2014-07-03 JC GT
ISSUE AMENDMENT DATE DRWN CHKD
COPYRIGHT
THE DESIGN ILLUSTRATED IN THESE DOCUMENTS IS THE EXCLUSIVE PROPERTY
OF DILLON FOLKER STEPHENS PTY. LTD. ACN 095 884 129 AND MUST NOT BE
REPRODUCED, OR USED IN WHOLE OR IN PART WITHOUT THE EXPRESSED
WRITTEN PERMISSION OF DILLON FOLKER STEPHENS,
APPROVAL ONLY
NOT FOR CONSTRUCTION
A
DFS GROUP
INTEGRITY : EXCELLENCE » SUCCESS
T 07 5443 5566
F 07 5443 9977
[email protected]
dfs.com.au
TOWN PLANNING
LANDSCAPE ARCHITECTURE
LIQUOR LICENSING
ENVIRONMENTAL
CHECKED
LA
LANDSCAPE ARCHITECT
TITLE
Cover Sheet
Notes and Schedules
PROJECT
Proposed Residences
FOR
Tu Projects
AT
28 Nannygai Street Noosaville
SCALE
n/a
DRAWING NO.
CD-001
PROJECT NO
| 14073
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 2 pages
Page 2
25 SYZ RES
7 SYZ RES ——}4
16 SYZ RES
Sewer
1 BAC cit
4 PHI XAN
FEN-3
f 1 BAC cit
4LIREG
yp 5SYZRES
/ 5 SYZ RES
y~5 PHIXA
| .FEN-3
FEN-1
“ee ~e_
ef e
~e ew ee ew
ee
=
ewe
———~ 2 ACM AM
Turf Type 1
- refer to Sched
HC OX
ule
Clothes line
-—— 12 ACM AM
;— 7CALLJ
NIT 4
FFL 2.50
14 TRA jas —2<
ew
7 SYZ RES
6 BLE car
eo
gay
FL
oe oe
ee ‘ “s
4 ee
oo @
L
oO
(P03)
O
=
I
AVR VE
Clothes line
OO
U
F
— 13LIREG
| ——— 2LOMSH
FEN-1
x
a
1 CYA coo
Bin storage area ———
HC
UU Hy
ooo 8
0000
wu
Oo
Oo
U
ao
Oo
;—{Po3)
HC
1200 high wall of
pool structure
Pool plant access
el
eo
FEN-2|
J
4 HIB sca
ad
4.
4TULvio 4
ra J
fan 4044
So oe
} asf aa
} 46a aay
Raa a
a4 ant ea
aCe as
=<i3—(P04
oyean fe x J
44
aattad
X&
1 CIT MEY, 4
1 CYC rev
4 2IHIB sca g
fyUL aa 4
saan 4
4
1 CIT lat
J
3 TUL vid
wantfa 4
4 A
Cereer
\— 5 CALLJ
3 ACM AM
NN
Turf Type 1
- refer to Schedul
eee of
o_ ¢ 6 _ S&F ©.
~~ 9 ACM AM
4 COR“ru RUB
LA
A
J
4
X&
3)
3
=
IN
4
‘&
- 3 SYZ RES
6 TUL vio
A
J 5 TUL vio
4 44
8 MET FF
J
*\
Ms
N
6 DIALJ
&
4
A
v 9 HIB sca
4
1 LIV aus,(2m)
46 ACMAM >
| |
| ; Z
| J
g A. | —_—— 1 LIV aus (2m)
/ yp 5 MET FF
t+— 10 DIA LJ
7 Wes fru
Path
- Nom.2m wide
;—— Exsiting power pole
r__ Existing crossover
to be removed
- refer to Engineer
1 XAN chr
Verge turf
2 GRE SU
3 DOR pal
——1 CUP ana
1 XAN chr
A -—
[YARIS
WLT-1
\_ 2COR fru RUB ~
A
J
4 og A
/— 3 COR Tu RUB
=
oO
=
(Pot)
X&
Unit
Unit
UNIT 2
FFL 2.50
/ 3x2m Garden shed location
/ (P03
/
HC
ve
Og
UUUUUU
~.
oOo
Wn
HC
;—— Bin storage area
go
Oo
(P03)
Oo
~
6 BLE car
1 CYA coo
16 LIREG
4 MET FF
FEN-1
QO
|
_®
s—— 16LIREG
}
o oe “e/|
YS
q
q
Clothes line
[Pos]
*
OO ae
OP
S62 020° q
—e_ «
eb 4 MET FF
IVa
Clothes line
UNIT 1
FFL 2.50
7 ACM AM —~
1200 high wall of
pool structure
Pool
8 ZOY ten
3 MET FF
5 COR fru RU
=
oO
(Po2|
3&4 Ietterboxes
4a
(Pot)
J
1&2 letterboxes
6 WES fru
~— Verge turf
—1 CUP ana
—— 3 DOR pal
Verge turf
Nannygal
Street
Verge turf
3 DOR pal
— 1CUP ana
7 WES fru
9 SYZ TT—
BES
an a
ay ea
> FEN-1
1 XAN chr
2 GRE SU
3 DOR pal
—1CUP ana
1 XAN chr
7 WES fru
Existing crossover
to be removed
- refer to Engineer
Path
- Nom.2m wide
Exsiting power pole
i
WLT-2
4LIREG
1 BAC cit ——~
| Z— 4UIREG
1 BAC cit
\__ 8 SYZ RES
3 PHI XAN
0 DIALJ
Extent of path
- refer to Architect
Note:
Refer Cover Sheet for legend.
2014-07-08 JC GT
DATE DRWN CHKD
A APPROVAL
ISSUE AMENDMENT
COPYRIGHT
THE DESIGN ILLUSTRATED IN THESE DOCUMENTS IS THE EXCLUSIVE PROPERTY
OF DILLON FOLKER STEPHENS PTY. LTD. ACN 095 884 129 AND MUST NOT BE
REPRODUCED, OR USED IN WHOLE OR IN PART WITHOUT THE EXPRESSED
WRITTEN PERMISSION OF DILLON FOLKER STEPHENS,
APPROVAL ONLY
NOT FOR CONSTRUCTION
A
DFS GROUP
INTEGRITY : EXCELLENCE » SUCCESS
T 07 5443 5566
F 07 5443 9977
[email protected]
dfs.com.au
TOWN PLANNING
LANDSCAPE ARCHITECTURE
LIQUOR LICENSING
ENVIRONMENTAL
CHECKED
J LA
LANDSCAPE ARCHITECT
\\)
TITLE
External Works & Planting Plan
PROJECT
Proposed Residences
FOR
Tu Projects
AT
28 Nannygai Street Noosaville
SCALE
1:75@A1, 1:150@A3
DRAWING NO.
CD-002
PROJECT NO
| 14073
Page 3
Notes:
- Place the rootball on a firmed base to achieve required FSL.
- Thoroughly water the root ball immediately after planting.
- Number of stakes will vary with pot size. Refer plant schedule.
- Cultivate sides of excavated hole 50mm.
Hardwood Stake: 25x25x90mm voy 2
Place 600mm into the ground. ss
Do not place through rootball. 5
Secure with ties by looping ina
figure eight pattern.
Mulch: Pull away from
base of plant.
Form an earthen basin
around base of plant.
r
\
Topsoil blend
Fertiliser: Do not allow
contact with roots.
Water retention additive
£01\140mm TO 300mm PLANTING DETAIL
\ed-200 1:10@AT; 1:20@A3
Notes
1. Construction joints: Place at minimum 5m centres.
2. Tool joints: Make tool joint at equal distances from both
ends. Make joint at points of change in curvature/ direction.
Joints to be at right angles to direction of edge.
Mulch - refer to Specification.
Continuous extruded mowing
strip. Profile as indicated
below.
Yo,
44 <— Turf - refer to Specification.
Ui <— Topsoil - refer to Specification.
XS Z
<>
QD
KLEEB SASH HS SSS Cultivated subgrade - refer t
Mi) Zo SEESISSSSISSSEK — teagan
BRL’ x
SOE LGR EEE EE RE RE REO
KKK XK Uae S 2 Compacted subgrade to be
PSS ELL Pp g
Eee <?
? Nom. 200mm thickness.
04\ EDGE TYPE 1
0-200) 1:10@A1; 1:20@A3
FSL +
TIMBER EDGE
100
Sy
Timber edge Notes:
LI - All timber to be CCA pressure treated to
Stakes AS1604, Hazard 5, rough sawn pine.
- All timber ends to have one coat of Cuprinol
or equal prior to installation.
- Stakes to be 400mm into ground at max.
1200mm centres, or as required to obtain
smooth curves. Top of stake to finish 20mm
below top of timber edge. Where timber
edges meet at corners provide double stakes.
- All fixings to be hot dipped galv.
- Leading edge is to be free of burrs and
splinters.
N\
\— Existing/compacted
/subgrade/subase
A
~
KK
YN
STAKES
25
!
/05\EDGE TYPE 2
\ep-200/ 1:5@A1; 1:10@A3
(X) = Height above
finished surface level
DX FLusH
20mm
[ | 100mm
[ | 150mm
FIXINGS
50mm Bugle Headed
Batten Screws.
75mm Bugle Headed
Batten Screws.
100mm Bugle Headed
Batten screws.
38
Continuous Edging Profiles
1. Edge radii: All radii 20mm
Notes:
- Place the rootball on a firmed base to achieve required FSL.
- Thoroughly water the root ball immediately after planting.
- Number of stakes will vary with pot size. Refer plant schedule.
- Cultivate sides of excavated hole 50mm.
Hardwood stake: Place 600mm
—
into the ground. Do not place
through rootball. Secure with ties
by looping in a figure eight pattern.
Raise plant 50mm above
finished surface level.
Mulch: Pull away from base
of plant.
Form an earthen basin
around base of plant.
Topsoil blend
Water retention additive
Fertiliser: Do not allow
fertiliser to come in
contact with roots.
VIVV VV V VATE VY NN
’ width (w)—s-sp5
10 - 20mm Drainage gravel —__439 Vv oy Vv Ww) Vv ae.
YVVYVUVUV2KXWVET TV Tp
thoes ooo ee ae
(0245ltr TO 200Itr PLANTING DETAIL
\eb-200/ 1:10@A1; 1:20@A3
1:5@A1; 1:10@A3
2. Adjacent surface levels: As shown by FSL on profiles
Notes:
- Place the rootball on a firm base.
- Thoroughly water the root ball immediately after planting.
- Cultivate sides of excavated hole 50mm deep.
- Do not disturb kerb, road pavement or road side drainage works. ~T
Timber stake: Place 600mm into ——>
the ground. Do not place through
rootball. Secure with ties by
looping in a figure eight pattern.
Raise plant 20-30mm above
top of kerb.
Do not excavate
within 50mm of
edge restraint or
pavement.
Mulch: Pull away
from base of plant.
Form earthen basin
around base of
Distance to local
authority
requirments
Top of Kerb
FSL
Topsoil blend
Fertiliser: Do not allow
contact with roots.
Water retention
additive a
Drainage gravel
VVVTVV TTT
VVVVVVVVVVIVVV VV VVI VV
VVVVVVVVVVVVVVVV VV VV YS
WvVyVyvvvvvvvvvvvvvVvvvvvVy
7—— Root barrier
(03 \STREET TREE PLANTING DETAIL
\e0-200) 1:10@A1; 1:20@A3
100 1 (25
Palings
- to be butt joined
fit i L
+
[
Rail
Capping rail over ~——— Post
Capping - 100x25mm
Post
- 5° fall on top
Rail
Paling
Paling - refer to notes
eq.
eq.
|
oI
BK
SSS
1800
Post - refer to notes
Rail - refer to notes
Footings - Round top
of footings to shed
water.
Fence Type 1 Notes:
100
350dia.
|
t
max.2400 centres
(06 \FENCE TYPE 1
\ CD-200 / Elevation - 1:20@A1; 1:40@A3
ee Details - 1:10@A1; 1:20@A3
10mm dia.
6 30mm.
650
900mm.
Gravel we
nom.100
1. Palings to be CCA pressure treated pine 100 X 19mm to
AS1604 Hazard 3. Fix palings with 2 (No.) 50mm x 2.5mm
ml screw shank or ring shank HDG nails to each rail.
- Fix palings to rails as shown. Overlap of palings to be
2. Posts to be CCA treated HWD to AS1604, Hazard 5,
2 refer spec. Aris all edges. All posts to be 100 x 100mm,
evenly spaced with a maximum spacing of 2400mm.
Corner posts and end posts to have footings to a depth of
3. Rails to be CCA treated Pine to AS 1604, Hazard 3 100 x
50mm as per spec. Butt join rails as shown on alternative
posts where possible. Screw rails to posts with 1(No.) Type
17 100mm Bugle Head Batten Screws. Aris all edges.
4. Capping to be CCA pressure treated pine to AS1604,
Hazard 3 100 x 25mm. Screw capping to rail with 1(No.)
edges.
P Type 17 Bugle Head Batten Screws @ 600 cts. Arris all
5. Hot dip galvanise all screws and fittings. Coat with a film
of grease or a bitumestic product before use.
Note:
Refer Cover Sheet for legend.
A
A APPROVAL 2014-07-03 JC GT
ISSUE AMENDMENT DATE DRWN CHKD
COPYRIGHT
THE DESIGN ILLUSTRATED IN THESE DOCUMENTS IS THE EXCLUSIVE PROPERTY
OF DILLON FOLKER STEPHENS PTY. LTD. ACN 095 884 129 AND MUST NOT BE
REPRODUCED, OR USED IN WHOLE OR IN PART WITHOUT THE EXPRESSED
WRITTEN PERMISSION OF DILLON FOLKER STEPHENS,
APPROVAL ONLY
NOT FOR CONSTRUCTION
DFS GROUP
INTEGRITY : EXCELLENCE » SUCCESS
T 07 5443 5566
F 07 5443 9977
[email protected]
dfs.com.au
TOWN PLANNING
LANDSCAPE ARCHITECTURE
LIQUOR LICENSING
ENVIRONMENTAL
CHECKED
Lala
LANDSCAPE ARCHITECT
TITLE :
Landscape Details
PROJECT
Proposed Residences
FOR
Tu Projects
AT
28 Nannygai Street Noosaville
SCALE
1:75@A1, 1:150@A3
DRAWING NO.
CD-002
PROJECT NO
14073