Existing MCU and OPW Approval · MCU26/0012.01
Building Height
7. The maximum height of the development must not exceed 8.0 metres above the ground level
including where excavation is undertaken the exposed portion of the external façade of the
building.
8. Certification must be submitted to Council from a Registered Cadastral Surveyor (Qld) which
certifies that the buildings do not exceed the maximum height requirement of this Decision
Notice.
External Colours & Finishes
9. External colours and finishes must be of muted environmental tones that blend with the
surrounding vegetation and landscape, with broad expanses of a single colour or reflective
surfaces not permitted.
Car Parking
10. A minimum of 2 car parking spaces must be provided on site and made available and
accessible at all times for residents. Vehicle manoeuvring areas are provided on site in
accordance with the Australian Standards for Off-street car parking so vehicles enter and
leave the site in a forward gear.
Lighting Amenity
11. No flood lighting must be used on site. Any vertical illumination resulting from direct, reflected
or other incidental external lighting emanating from the site must not exceed 8 lux when
measured at any point 1.5 metres outside the boundary and at any level from ground level
upward.
Environment
12. Sediment or any other material including building materials or waste products must not be
deposited or released into the road reserve, stormwater drain or adjacent properties.
Landscaping Works
13. A minimum of 20% of the site must be retained as soft landscaping.
14. Areas of the site proposed to be cut or filled to establish the approved development are
required to be landscaped and returned to a either a grassed or landscaped setting. Areas
of exposed earth hillside resulting from the development is not approved.
15. Existing vegetation in the road reserve must be retained, unless written authorisation from
Council is granted for the clearing.
16. All excavation/fill and associated batters must be contained entirely within the subject site
unless written permission from the respective landowner(s) is provided to Council. All
earthworks must be undertaken in accordance with the provisions of Australian Standard
AS3798: Guidelines on Earthworks for Commercial and Residential Developments.
17. All retaining walls must be designed and constructed in accordance with the planning scheme
and must be certified by an RPEQ where exceeding 1.0m in height.
Water Supply
18. The approved dwelling must be serviced with a rainwater tank having a minimum storage
capacity of no less than 60,000 litres.
Site Access and Driveways
19. An access driveway must be provided from Lukes Rd to all parking and manoeuvring areas
of the development. The works must be undertaken in accordance with Driveway Levels Plan
Part 1 & 2 prepared by SCG Engineers (00577-OW4.1 & 00577-OW4.2) and dated February
2026.
Page 3 of 10
Document Set ID: 24721885
Version: 3, Version Date: 30/04/2026
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Existing MCU and OPW Approval.pdfRelated documentApplication case desk ↗
About this file
- File size
- 161 KB (small file)
- File type
No other editions are linked here.