Council archive · source document
Proposal plans · MCU22/0154.01
Plans and drawings: the text below has words only, no drawings.
1 2 3 4 DA SUBMISSION
NOT FOR CONSTRUCTION
DEVELOPMENT INFORMATION FLOOR PLAN NOTES
RPD LOT 74 on 74P9313 01. SUB-FLOOR, FLOOR, WALL AND ROOF
FRAMING TO BE DESIGNED AND
A 214 DAVID LOW WAY
PEREGIAN BEACH, QLD 4573
CERTIFIED BY A REGISTERED
STRUCTURAL ENGINEER.
30.01
02. LINTELS, TIEDOWN AND BRACING TO
SITE AREA 270m² STRUCTURAL ENGINEERS DESIGN AND
CERTIFICATION.
03. ALL GLAZING TO BE INSTALLED IN
GFA CALCULATIONS ACCORDANCE WITH THE NCC. UPPER
BASEMENT LEVEL 50m² LEVEL GLAZING TO 1M HT ABOVE FFL
IS TO BE GRADE A SAFETY GLASS AS
11950 14920 2560 GROUND LEVEL 185m²
A MINIMUM.
LEVEL 01 193m² 04. STAIR CONSTRUCTION TO COMPLY WITH
building over shown dashed NCC. ALL STAIR FRAMING, TREADS AND
A PROPOSED GFA 428m²
LANDINGS TO BE DESIGNED AND
CERTIFIED BY A REGISTERED
STRUCTURAL ENGINEER.
2165
05. HANDRAILS AND BALUSTRADES TO
COMPLY WITH NCC AND BE
CONSTRUCTED TO TAKE LOADING
FORCES TO AS 1170.1.
DUMB 06.. A PLY SUBSTRATE IS TO BE INSTALLED
WAITER UNDER ALL INTERNAL TIMBER FLOORS.
07. ALL PANEL FLOORING TO BE FIXED IN
ACCORDANCE WITH MANUFACTURERS
STORAGE
5340
LIFT PIT SPECIFICATION.
RL +6.110 08. ALL WET AREAS TO HAVE A 50mm
50m2 STRUCTURAL SETDOWN TO ALLOW FOR
FLUSH DOOR THRESHOLDS AND FALLS
TO WASTES.
09. ALL WET AREAS TO BE SHEETED WITH
APPROVED FIBRE CEMENT SHEETING
AND TO BE CONSTRUCTED AND
WATERPROOFED IN ACCORDANCE WITH
THE RELEVANT CLAUSES OF THE NCC.
2945
10. THE CONSTRUCTION AND FITOUT OF
COMMERCIAL KITCHENS AND BARS IS TO
COMPLY WITH AS 4674 - 2004.
B building over shown dashed
11. PROVIDE LIFT OFF HINGES TO TOILET
AND BATHROOM DOORS.
12. TERMITE PROTECTION IS TO BE
PROVIDED TO COMPLY WITH
AS 3660.1 - 2000 AND
CERTIFICATION IS TO BE PROVIDED ON
C 13.
COMPLETION.
ALL EXISTING SURFACES / MATERIALS
/ ITEMS REMAINING IN THE PROPOSED
WORKS ARE TO BE MADE GOOD. ALL
EXISTING PAINTABLED SURFACES TO BE
RE-PAINTED.
WALL ORIENTATION
FLOOR PLAN - BASEMENT LEVEL
SCALE 1 : 100 A
D B
C
WALL TYPES
1 2 3 4
EXISTING WALL/ITEM TO REMAIN
PROPOSED WALL
FFL 22.550 FINISHED FLOOR LEVEL
SSL 22.550 STRUCTURAL SLAB LEVEL
ADJOINING RETAIL
cleaners sink and
CP SP284446 A
30.01
grease trap cupboard
gas bottles switchboard and services
A
SERVICE CORRIDOR
KITCHEN
BINS DUMB
PWD
WAITER
EXISTING
CARPARK
LIFT B ISSUE TO PLANNER NG 27.09.2023
A PRELIMINARY ISSUE NG 18.09.2023
issue revision by date
TENANCY 01 TENANCY 02 TENANCY 03 do not scale off this drawing - all dimensions are subject to
site measurement and verification
RL +9.360 RL +9.360 RL +9.360
100m2
35m2 28m2 FOYER
cobblestone © KP Architects Pty Ltd ABN 40 068 270 806
KP ARCHITECTS
awning over shown dashed
43 Doggett St Teneriffe Q4005 p 07 3216 1466
PO Box 2285 Fortitude Valley Q4006
SHOP WINDOW SHOP WINDOW [email protected] www.kparchitects.com.au
B
landscaping strip raised planter landscaping strip
client MURRAY THORNTON
void over shown
dashed EXISTING LANEWAY
awning over shown dashed metal screen + gates
C project PEREGIAN BEACH RETAIL
DEVELOPMENT
drawing title FLOOR PLANS
drawn by NG
date SEPT 2023
FLOOR PLAN - GROUND LEVEL scale 1 : 100 @A1
SCALE 1 : 100
0 1 2 3 4 5 m
drawing number
23011- DD 10.01 B
PLOT DATE/TIME: 27/09/2023 4:21:53 PM
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Proposal plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 9.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.