Original source · versioned page text
Glen - REC13/0146 Flood Study BSM 30 April 2014. Email 2 Attachment 2
Attached to the e-mail REC13/0146 - Response to Information Request - Email 2.
DECK LEVEL 100.55 (10 YR FLOOD LEVEL)
0.25 M 0.4 M
APPROACH FILL APPROACH FILL
0.2 M DIA PILE IL 98.63
0.45 M DIA PILE
PROPOSED FOOTBRIDGE, LOOKING DOWNSTREAM
(ONE 8.8 M CLEAR BRIDGE SPAN, PLUS THREE 2.2 M CLEAR BOARDWALK SPANS)
Q5 STORAGE LEVEL
Q1 STORAGE LEVEL
0.3 M BIO-STORAGE 0.7 M 0.4 M 0.1 M
WEIR
N-3
1-O
SAND SURFACE AREA 200 M2
1 M x 1M (INT) RISER BOX
0.7 M WIDE x 0.4 M DEEP NOTCH IN ONE SIDE
OUTLET PIPE, DIA AS REQ'D SAFETY / TRASH RACK AS REQ'D
TO CONVEY Q5 = 0.63 M3/SEC
BIO-BASIN SCHEMATIC, WESTERN TRIBUTARY
Q5 STORAGE LEVEL
0.2 M BIO-STORAGE
0.2 M 0.07 M Q1 STORAGE LEVEL
WEIR
-5
1 - ON
SAND SURFACE AREA 150 M2
1 M x 1M (INT) RISER BOX
1.0 M WIDE x 0.2 M DEEP NOTCH IN ONE SIDE
OUTLET PIPE, DIA AS REQ'D SAFETY / TRASH RACK AS REQ'D
TO CONVEY Q5 = 0.35 M3/SEC
BIO-BASIN SCHEMATIC, EASTERN TRIBUTARY
28 Apr 2014
VALKEV PTY LTD - ELM STREET AND LAKE MACDONALD DRIVE, COOROY
FOOTBRIDGE AND BIO - BASIN SCHEMATICS FIGURE 12