Council archive · source document
Amended - Decision Notice - Negotiated - MCU22 0145 & OPW22 0212 [As Published] · MCU22/0145
C2.1 - Elevation (West) prepared by Chris Clout 21.11.23
Design
C2.2 - Elevation (South) prepared by Chris Clout 21.11.23
Design
C2.3 - Elevation (North) prepared by Chris Clout 21.11.23
Design
C3.1 - Section 2 prepared by Chris Clout Design 21.11.23
C3.3 - Section 4 prepared by Chris Clout Design 21.11.23
C3.4 - Section 5 prepared by Chris Clout Design 21.11.23
C3.6 - Section 7 prepared by Chris Clout Design 21.11.23
C3.7 - Section 8 prepared by Chirs Clout Design 21.11.23
Amendments • The balustrades, acrylic pool window, planter boxes on rooftop
terrace must not exceed a maximum height of 1.2 metres as
generally depicted on Drawing Numbers C2.0, C2.1, C2.2,
C2.3 and dated 4 July 2023 and to the reasonable satisfaction
of the Manager Development Assessment.
Building Height
4. The maximum height of the development must not exceed 12 metres above the natural
ground level and the exposed portion of the external façade of the building including where
excavation is undertaken.
5. The ground level must be reinstated around the basement level to ensure no part of which is
more than 1 metre above ground level, apart from the driveway entrance.
6. Certification must be submitted to Council from a Registered Cadastral Surveyor (Qld) which
certifies that the building does not exceed the maximum height requirement of this Decision
Notice.
Building Appearance
7. External design features, materials and finishes must be as shown on the Approved Plans,
with no inclusions or alterations made without approval in writing by Council, apart from as
conditioned as plan amendments.
8. External finishes of the building must be a mix of lightweight and textured external finishes,
with masonry areas incorporating a variety of textured finishes to break up the surface.
9. With the exception of the lift shaft and stairs, no wall or privacy screen at Level 4 must be
higher than 1.7 metres.
10. All deck and balcony areas must not be enclosed with shutters, louvres, glass panelling or
the like thus remaining as open structures, except where required to satisfy any privacy
condition of this Decision Notice.
11. All balustrades to decks and balcony areas must be open or transparent.
12. External colours and finishes must be of an understated colour scheme and low-reflective
roofing and cladding materials.
13. The development must not exceed a maximum plot ratio of 0.65:1 with the areas identified
as voids on the Ground Floor, Level 2, Level 3, and Level 4 to remain open as full open void
areas at all times.
Page 3 of 16
Document Set ID: 22808839
Version: 2, Version Date: 12/02/2024
See the original