                                       AO13.2    Vehicular access avoids              The proposed driveway is
                                                 disturbance to the tree              located within an existing
                                                                                      clearing and avoids any
                                                 protection zone of trees on
                                                                                      disturbance to vegetation.
                                                 public land.
PO14   Driveways and crossovers      AO14.1 Only one driveway and          Only one driveway is proposed
       are located so they do not           crossover is provided.         for the dwelling.
       impede the safe and efficient
       use of the road network.
                                     AO14.2 Where the premises has         N/A
                                            frontage to more than one
                                            formed and sealed road and the
                                            roads have differing orders in
                                            the Road Hierarchy, the
                                            driveway and cross­over is
                                            provided on the frontage with
                                            the lower order.


                                        AO14.3 For corner lots, driveways             N/A
                                               and crossovers are located
                                               in accordance with Council’s
                                               standard drawings.


                                        AO14.4   If in the Rural zone or Rural        The driveway crossover will be
                                                 Residential zone, the driveway       constructed to provide a
                                                 and cross­over is located to         minimum safe sight distance in
                                                 provide minimum safe sight           accordance with Austroads.
                                                                                      Crossover is to an existing
                                                 distances in accordance with
                                                                                      access easement that services
                                                 Austroads.                           3 allotments.
PO15   Bushfire hazard                  AO15     Within a bushfire hazard area        The site is not located within the
       management:                               where there is no reticulated        Local Government or State
                                                                                      Planning Policy Bushfire overlay
                                                 water supply, the premises
                                                                                      mapping.
       Where located in a Bushfire               has:
       Hazard Area as shown on                   (a)    an accessible dam,
       the Bushfire Hazard Overlay                      swimming pool or water
       Map in Schedule 2 and not in
                                                        tank       available    for
       a water service area, an
       adequate, reliable, safely                       firefighting      purposes
       located and freely accessible                    with an onsite water
       water supply is provided for                     volume of not less than
       fire fighting purposes, which                    5,000 litres; and
       is in addition to day to day
       water supply.                             (b)    a water supply outlet
                                                        pipe 50 millimetres in
                                                        diameter and fitted
                                                        with a standard fire
                                                        brigade fitting
                                                        connected to the
                                                        water supply (other
                                                        than where the water
                                                        supply is in a
                                                        swimming pool or
                                                        dam).
PO16   Flood hazards:                   AO16.1   Where the development is      N/A
                                                 located in the Flood Hazard
       Development is designed                   Area as shown on Flood Hazard
       and sited to ensure risk to               Overlay Map in Schedule 2,
       people and property from                  the finished floor level of
       flooding is avoided or                    habitable rooms is at least
       minimised.
                                                                                                       23 | P a g e
Log in to download the original file

Planning Report.pdf · 728 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.