SD.601 SD.601
1,800
line of Al Fresco over
4,200
3,190
3,400
Vergola Roof
(to Alresco below)
privacy screens privacy screens
privacy screens
BED 1 BALC. BED 2 BALC.
bath
b
b
E/S 1 E/S 2
BED 2 privacy
screens FEATURE
BED 1 low stone planter
SITTING TREE
r 290 / bench seat
(PLANTER)
1,300 shr. 1,300 290
A shr. A A A
SD.601 OFFICE SD.601 SD.601 SD.601
lin 12,300
HOT TUB
store (lock) 5,900 HALL privacy
WIR screens
stairs PWD 2
LIFT DN UP 5,900 LIFT DN
shr.
b
990
990
890
B B
SD.601 SD.601
Level 1 Floor Plan 1:100 Level 3 Floor Plan 1:100
B B
SD.601 SD.601
1,700
deep landscaping privacy screens
3,190
4,700
3,610
LANDSCAPED VISITOR CAR
GARDEN / TURF grass pavers
for second
car storage privacy screens
1,910 BBQ ALFRESCO
UP shr. STORE STORE
710
PATIO
1,950
BED 3
(NOTE: MAXIMUM BUILDING
RUMPUS HEIGHT APPROX. 14M)
storage
GARAGE FLOOR AREAS - PROPOSED
290
KITCHEN LIVING
r Garage & Store 36.73m2
ent 1,200
A A A A Internal
SD.601 shr. SD.601 SD.601 SD.601
Ground 61.90m2
1,950
9,100 privacy Level 1 86.47m2
HALL ENTRY screens
UP BATH Level 2 74.10m2
UP fire
b entertainment Level 3 5.55m2
LDY. (under stairs) ___________________________
stairs
UP 2,700 PWD 1 DN UP 9,100 Internal Total 228.02m2
LIFT tub w/m dry LIFT
b
clothes External
Ground 12.16m2
1,900
1,200
Level 1 9.40m2
990
900
890
Level 2 30.08m2
Level 3 83.32m2
___________________________
External Total 134.96m2
B B
SD.601 SD.601
Grand Total 369.71m2
Ground Floor Plan 1:100 Level 2 Floor Plan 1:100
Project Client Scale Date Drawn By
This drawing is to be read in conjunction with Engineers Drawings & Reports. P R E L I M I N A R Y
Construction to comply with all relevant Standards Australia & BCA
codes,Building Act 1975 & Building Regulation 2006 (as amended) & the
PROPOSED NEW VILLA R & P HOLYMAN as shown @ A2 AUG 2018 GS
PO Box 1261, Noosa Heads
Queensland 4567 QDC.Verify all dimensions on site prior to commencement of any works. These Location Drawing Title Project No. Drawing No. Issue No.
THE HASTINGS 9-10
P (07) 5474 8888
QBCC license no. 1185052
drawings are not to be used for scaling. Copyright for design & drawings remain
the property of the authors. 30 HASTINGS STREET - NOOSA HEADS FLOOR PLANS 1804 SD.201 P8
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.