Original source · versioned page text
2024.10.16 - Tewantin Duplex Issue C
Fence
Bdy - Not Surveyed
Gas
Comms
Waterline
Centerline
O/H power
Stairs
Building
Bitumen
Kerb
GDA 2020 NORTH
ORTH
9
PIT 10.2
PERMANENT SURVEY MARK
TRUE N
Survey control station
10
.0
0 Top of gutter
.0
.098
47
tg
10
M eave 45.0 Underside of eave
kl 9kl.792.81
TB
O/s 0.05
9.92
O/s 0.01
O/s 0.53
O/s 0.05
10.65
91°20'00"
10
0.000
Spot height
10.18 10.47
41.229
.00
10.67 10.82
.0
Floor Level
45
10.50 O/s 0.03
O/s 4.10
FL
10.17 10.64 10.65
.53
Sewer
14
10.03 10.51
TG
.41
10.17 eave 14
10.45 Stormwater
10.48
10.52
kl 9kl.496.55 10.51 U/G electricity
O/s 0.19 Lot 4RP91287
FL 12.4
3 3 Werin Street 10.33
10.37 Vegetation
Area 734m2 10.32 10.37
9.65 10
9.83 .0 10.26
0 Floor 12.43
180°00'00"
0°00'00"
.55
18.286
Notes:
17.327
Ridge 17.24
14
10.17 1) This plan is not an Identification Survey
.51
9.77
TG
15
PIT 9.4
2 9.90 2) Underground Services may be scaled and
10.08
TG
kl 9.32 9.69 approximate only
3) Contact FSG on 0417703607 with any questions
.21
O/s 6.73 00 10.00
kl 9.23 10.
17
.41
ge
16
9.88
rid
ge
rid
9.88
FL 9.87
.55
kl 9.09
14
.34
58 eave 15 .41 SLMH 9.567
ilkl9.0
9.1
TG
eave 14 O/s 0.01
IL 8.02
9.39
O/s 3.71
kl 9kl.093.12 O/s 0.19
O/s 3.23
9.78 9.67
9.21 9.74 9.78 9.74
9.00 99.8.637
9.49 9.67
9.10
O/s 0.05
kl 8kl.995.04 9.16 9.52
9.00
270°00'00" I, Richard Alan Henderson of FOCUS SURVEY GROUP, hereby certify that the
41.219 vertical and horizontal locations,dimensions and volumes shown on this plan are a
true and correct record and were located and checked by survey.
190719
CPSSSI Surveyor No. 12546 Date: 19/07/19
O/s 7.38
ABN no. 89022151267
http://www.focussurveygroup.com.au
MOB 0417703607
0 4 8 12 16 20
C - Council RFI - coordination 16.10.24
pu GDA2020.plotframeppf Scale 1: on A3 B - added vehicle turntable, 15.07.24
C:\12d\15.00\SCC\User_lib_custom\A1 1A rh A3PLAN.tbf Proposed Duplex for widened driveway
PO Box 262 This drawing is to be read in conjunction
Noosa Heads QLD 4567 with Engineers Drawings & Reports Jen Grijmans JENStreet
3 Werin GRIJMANS, A - Issue for DA 24.05.24
Construction to comply with all relevant Project Scale Date
Mobile 0419 758 478 Lot 207 B92953 DUPLEX 1:1
SAA & BCA Codes & standard Bldg By-law
1975 & as amended
rh TEWANTIN @A3 APRIL
N 24
[email protected] rh 240229 Topographic Survey
Verify all dimensions on Location Drawn By Job No:
site prior to commencement
of any works. These drawings are not to be used
3 WERIN STREET DDT 2401
Rev No. Date Revision Details Rev By Ver By App By
GDA 2020 - GPS AHD der - GPS 1:200
for scaling Copyright for design & drawings
remain the property of the authors.
TEWANTIN - Sheet 1 of Drawing No. Issue No.
designers
GSPublisherVersion 2079.0.14.100
SD.102 C
See the original
The page text is free to read. Viewing or downloading an original file needs an account.