Original source · versioned page text
20.001-003 Construction Issue C5_SARA Revisions
Attached to the e-mail Combined Application MCU21/0021 & OPW21/0036 - 43 Wyuna Dr, Noosaville - Plans - DA Form 1 - Owners Consent - Title Search - Survey Plan.
Long View ASSOCIATED CONSULTANTS
L Consulting Engineers Pty. Ltd.
V Post:
ABN:
PO Box 963 Cooroy QLD 4563
98 867 060 985
Mobile: 0414 681 676
Email: [email protected]
Internet: www.longviewconsulting.com.au
PROJECT
PROPOSED NEW JETTY
43 WYUNA DRIVE, NOOSAVILLE QLD
PROJECT
SITE
LongView PROJECT No.: CLIENT
20.001-003 IAN MARTIN
LOCALITY PLAN
NOT TO SCALE
DRAWING SCHEDULE & TRANSMITTAL
REV. REV. REV. REV. REV.
DRAWING No. TITLE DATE: 10/07/20 17/07/20 29/07/20 06/10/20 19/10/20
S01 COVER SHEET (DRAWING SCHEDULE & TRANSMITTAL) C1 C2 C3 C4 C5
S02 STRUCTURAL NOTES SHEET C1 C1 C1 C1 C1
S03 SITE PLAN, FRAMING PLAN, ELEVATIONS C1 C2 C3 C4 C5
S04 JETTY FRAMING DETAILS - SHEET 1 C1 C1 C1 C2 C2
S05 JETTY FRAMING DETAILS - SHEET 2 C1 C1 C1 C1 C1
ISSUE "P1" DENOTES PRELIMINARY ISSUE 1
ISSUE "A", "B" DENOTES APPROVAL / TENDER ISSUE
ISSUE "C1" DENOTES CONSTRUCTION ISSUE 1
© THIS DRAWING IS PROTECTED ASSOCIATED CONSULTANTS PROJECT DRAWING TITLE
UNDER COPYRIGHT IN
ACCORDANCE WITH
AGREEMENT BETWEEN LONG
VIEW CONSULTING ENGINEERS
5
4
CONSTRUCTION ISSUE
CONSTRUCTION ISSUE
C5
C4
F.M.
F.M.
NOOSA JETTY BUILDERS
JoB No: 1291
Address:
Long View PROPOSED NEW JETTY
43 WYUNA DRIVE, NOOSAVILLE QLD
DRAWING SCHEDULE & TRANSMITTAL
Pty. Ltd. AND THE CLIENT AS
L Consulting Engineers Pty. Ltd.
REVISIONS
NAMED HEREIN. EXCLUSIVE 43 WYUNA DRIVE, NOOSAVILLE.
USE IS GRANTED UNDER THE
3 CONSTRUCTION ISSUE C3 F.M. LOT 21 ON N1057.6
AGREEMENT ONLY FOR THE
PROJECT. THIS DRAWING SHALL 2 CONSTRUCTION ISSUE C2 F.M. Client: IAN MARTIN V Post:
ABN:
PO Box 963 Cooroy QLD 4563
98 867 060 985
DRAWN
S.T.
CHECKED
F.M.
APPROVED DATE
19/10/2020
SCALE BAR DRAWING SCALES
1:1
DRAWING SIZE
A1 ORIGINAL
NOT BE CONSTRUCTED UNLESS Mobile: 0414 681 676
DESCRIBED AS "CONSTRUCTION 1 CONSTRUCTION ISSUE C1 F.M. Email: [email protected] DESIGNED CHECKED RPEQ / Cert. PROJECT NUMBER DRAWING NUMBER REVISION
ISSUE". Internet: www.longviewconsulting.com.au
No. DESCRIPTION REV. APP. F.M. F.M. 19951 20.001-003 S01 C5
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.
Full text of the other 4 pages
Page 2
GENERAL DIMENSIONS/LEVELS TIMBER FRAMING & BRACING:
G1 STRUCTURAL DRAWINGS SHALL BE READ IN CONJUNCTION WITH THE L1. CONSTRUCTION SHALL BE SET OUT USING SURVEY BENCHMARKS PROVIDED BY COUNCIL. T1 ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH AS 1720, AS 1684
SPECIFICATION, ARCHITECTURAL, AND OTHER CONSULTANTS' DOCUMENTS. AND THE REFERENCED STANDARDS THEREIN.
L2. ALL LEVELS AND SETOUT POINTS ARE SHALL BE CONFIRMED ON SITE BY REGISTERED
G2 REFER TO THE ARCHITECTURAL DRAWINGS FOR SETOUT. NO DIMENSIONS SHALL BE SURVEYOR PRIOR TO CONSTRUCTION. ADVISE ANY DISCREPANCY BEFORE PROCEEDING. T2 ALL FRAMING, BRACING AND TIE-DOWN INFORMATION FORMS THE BASIS OF THE
OBTAINED BY SCALING FROM DRAWINGS. STRUCTURES STABILITY DOWN TO FOUNDATIONS. ALTERNATIVE METHODS SHALL
L3. DIMENSION STANDARDS: ONLY BE ACCEPTED ON APPROVAL OF THE ENGINEER.
G3 UNLESS OTHERWISE NOTED (UNO), ALL LEVELS ARE IN METRES AND ALL DIMENSIONS ARE IN - REDUCED LEVELS, CHAINAGES AND COORDINATES ARE ALL IN METRES.
MILLIMETRES. - CIVIL DRAWINGS (SKC SERIES): ALL OTHER DIMENSIONS ARE IN METRES (m). T3 PREFABRICATED TIMBER ROOF TRUSSES, PROPRIETARY FLOOR JOIST SYSTEMS
- STRUCTURAL DRAWINGS (SKS SERIES): ALL OTHER DIMENSIONS ARE IN MILLIMETRES (mm). AND ALTERNATIVE TIMBER ELEMENTS TO THOSE SHOWN ON THE ENGINEERING
G4 THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING THE STABILITY OF THE DRAWINGS ARE TO BE DESIGNED AND CERTIFIED BY THE SUPPLIER'S STRUCTURAL
STRUCTURE UNTIL ITS COMPLETION AND SHALL ENSURE THAT NO PART OF THE STRUCTURE L4. ALL LEVELS ARE TO AUSTRALIAN HEIGHT DATUM. ENGINEER. DESIGN AND INSPECTION CERTIFICATES FOR THESE ELEMENTS ARE TO BE
IS OVER-STRESSED BY EXCESSIVE LOADING. ISSUED TO THE CONTRACTOR FOR LODGEMENT WITH THE LOCAL AUTHORITY.
L5. DIMENSIONS SHALL NOT BE SCALED FROM DRAWINGS.
G5 ALL MATERIALS AND WORKMANSHIP SHALL BE IN ACCORDANCE WITH THE CURRENT VERSION T4 ALL TIMBER MEMBERS USED ARE TO HAVE A MINIMUM LEVEL OF DURABILITY AS
OF THE APPLICABLE STANDARD EXCEPT WHERE VARIED BY THE SPECIFICATION AND/OR L6. DESIGN USES DIGITAL TERRAIN MODEL GENERATED FROM THE SITE SURVEY. SOME SPECIFIED IN AS1684.2 - APPENDIX B.
DRAWINGS. APPLICABLE CODES OF PRACTICE INCLUDE BUT ARE NOT LIMITED TO THE ELEMENTS ARE INTERPOLATED AND MAY VARY FROM THE ACTUAL SITE CONDITIONS
FOLLOWING: T5 ALL HWD TIMBER SHALL BE SEASONED UNO.
AS 1163 STRUCTURAL STEEL HOLLOW SECTIONS
AS 1170 SAA LOADING CODE T6 ALL TIMBER SHALL BE FREE OF GUM VEINS, KNOTS, SHAKES, CHECKS, WANES AND ANY
AS 1554 WELDING OF STEEL STRUCTURES CONSTRUCTABILITY CONSTRAINTS: OTHER IMPERFECTIONS WITHIN CONNECTION ZONES.
AS 1664 ALUMINIUM STRUCTURES
AS 1684 RESIDENTIAL TIMBER-FRAMED CONSTRUCTION CC1. CONSTRUCTABILITY CONSTRAINTS: T7 ALL TIMBER FRAMING TO BE MINIMUM H6 TREATED UNO.
AS 1720 TIMBER STRUCTURES
AS 2159 PILING CODE A) PROTECT ALL EXISTING INFRASTRUCTURE (EG CULVERT CROSSING, PAVEMENTS, T8 EXPOSED FRAMING (TIMBER FRAMING THAT MAY BE SUBJECT TO PERIODIC WETTING):
AS 4100 STEEL STRUCTURES FENCING & ELECTRICAL POLES/WIRES) FROM ANY DAMAGE. - SHALL BE EITHER H6 PRESSURE TREATED OR DURABILITY CLASS 1
AS 4997 GUIDELINES FOR THE DESIGN OF MARITIME STRUCTURES SPECIES (MINIMUM) SAWN TIMBER (UNO)
AS 5100 BRIDGE DESIGN B) ALLOW OF LIKELIHOOD OF FLOW WITHIN THE WATERWAY: EXISTING WATERWAY ARE
BCA BUILDING CODE OF AUSTRALIA (NATIONAL CONSTRUCTION CODE) FLOODED MULTIPLE TIMES PER YEAR. PROTECT CONSTRUCTION EQUIPMENT AND T9 WASHERS SHALL BE PROVIDED UNDER ALL NUTS AND BOLT HEADS (EXCEPT CUP-HEAD
WORKS. BOLTS) BEARING AGAINST TIMBER AS FOLLOWS:
G6 ANY DISCREPANCY SHALL BE REFERRED TO THE SUPERINTENDENT FOR A DECISION BEFORE BOLT SIZE WASHER
PROCEEDING WITH THE WORK. CC2. NO WORK TO COMMENCE ON SITE UNTIL: <=M12 50X50X3.0mm
M16 57X57X4.0mm
- OFFICIAL PRE-START MEETING HELD AND PRE-START MEETING MINUTES ISSUED
G7 ALL PROPRIETARY PRODUCTS NOT DEEMED TO COMPLY WITH THE BCA SHALL HAVE M20 65X65X5.0.mm
- CONTRACTOR'S MANAGEMENT PLANS SUBMITTED (SITE, TRAFFIC, ENVIRONMENT,
THIRD-PARTY CERTIFICATION WITH RELEVANT TESTING AND SIGN-OFF BY AN RPEQ ENGINEER. >M20 75X75X6.0mm
SAFETY) FOR SUPERINTENDENT'S REVIEW.
PROPRIETARY PRODUCTS INCLUDES PREFABRICATED TRUSSES, LIGHT-GAUGE STEEL
FRAMING, FLOORING PRODUCTS, RECYCLED TIMBER AND PLASTICS, BALUSTRADES, SCREENS, T10 X….. INDICATES M12DIA ANCHOR ROD/BOLT
SHADE FABRICS, JOINERY, PARTITIONS AND OPERABLE WALLS.
T11 [X]….. INDICATES M16DIA ANCHOR ROD/BOLT
G8 REFER TO ARCHITECTS DRAWINGS FOR DETAILS OF ALL GROOVES, FILLETS, HOBS, DRIP
DRIVEN PILES:
GROOVES AND THE LIKE. T12 SB…. INDICATES STRAP BRACE ROOF BRACING FIXED TO TOP OF EACH JOIST WITH 2
P1. PILES SHALL BE CONSTRUCTED IN ACCORDANCE WITH AS2159. SCREWS. BEND STRAP BRACING OVER AT ENDS, FIX WITH 2 SCREWS TO TOP OF JOIST
G9 GIVE AT LEAST 24 HOURS NOTICE OF AN INSPECTION BEING REQUIRED FOR : AND 4 SCREWS TO SIDE FACE OF SUPPORTING MEMBER. ALL ROOFS TO BE BRACED.
P2. CONSTRUCTION CONSTRAINTS: AVOID LOADING EXISTING REVETMENT WALLS.
- PILING
- JETTY FRAMING (TIMBER) T13 ALL FASTENERS ARE TO BE GRADE A4-70 STAINLESS STEEL IN ACCORDANCE WITH
P3. DESIGN LOADS: PILES TO ACHIEVE GEOTECHNICAL CAPACITIES (VERTICAL & ISO-3506-1. EXTERNAL ANCHORS WHERE SUBJECT TO SALT AIR SHALL BE STAINLESS
- BRACING AND TIE DOWN
HORIZONTAL) SHOWN ON THE DRAWINGS STEEL A4-70:
G10 ALL FABRICATION SHOP DRAWINGS SHALL BE PROVIDED TO THE ENGINEER FOR REVIEW AND -SCREWS TO BE NO.14 TYPE 17 WITH 50MM EMBEDMENT (UNO)
P4. REQUIRED PILE POSITION TOLERANCES: -ALL JOIST HANGERS, FRAMING ANCHORS, TRIPLE GRIPS AND THE LIKE, SHALL BE
COMMENT IN A3 HARDCOPY OR PDF FORMAT.
STAINLESS STEEL. TO BE MANUFACTURED BY PRYDA OR APPROVED
PLAN POSITION: +/- 50mm AT UNDERSIDE OF EACH GROUND BEAM. EQUIVALENT, WITH 5 NO. 2.8mm DIA X 30MM
G11 ABBREVIATIONS (GENERAL):
PILE VERTICALITY: NAILS EACH LEG MINIMUM. INSTALL AS PER MANUFACTURERS SPECIFICATION.
NTS NOT TO SCALE
- WITHIN 4% FOR ALL PILES
UNO UNLESS NOTED OTHERWISE
NSOE NOT SHOWN ON ELEVATION T14 PROVIDE BLOCKING OVER SUPPORTS AT 1800 MAX CRS IN ACCORDANCE WITH AS 1684
P5. PILE TOE LEVELS ON THE DRAWINGS ARE ESTIMATED LEVELS. ACTUAL TOE LEVELS FOR TIMBER BEARERS AND JOISTS WITH D/B >= 4.
NSOP NOT SHOWN ON PLAN
SHALL BE DETERMINED DURING CONSTRUCTION BY AN RPEQ-CERTIFIED
TYP TYPICAL
GEOTECHNICAL ENGINEER. T15 FOR JOISTS WITH SPAN >3000 AND BOTTOM OF JOIST UNRESTRAINED BY CEILING
(O) OVER
(U) UNDER DIAPHRAGM:
P6. DO NOT FOUND PILES HIGHER THAN TOE LEVELS ON DRAWINGS, UNLESS APPROVED BY -PROVIDE 1 ROW OF BLOCKING BETWEEN EACH JOIST AT
CRS CENTRES
BOTH THE SUPERINTENDENT AND THE GEOTECHNICAL ENGINEER. THE MIDSPAN FOR SPANS < 4200mm
NOM NOMINAL
SUPERINTENDENT SHALL SEEK ADVICE FROM THE DESIGN ENGINEER AS REQUIRED. -PROVIDE 2 ROWS OF BLOCKING BETWEEN EACH JOIST AT
CFW CONTINUOUS FILLET WELD
THIRD POINTS FOR SPANS >4200mm
T16 FIXING LOCATIONS TO BE FIXED ACCORDING TO THE FOLLOWING MINIMUM PACINGS
DESIGN CRITERIA ALUMINIUM: (D = FIXING SHANK DIA. IN mm):
BOLTS 4D EDGE DISTANCE TO BOTH EDGES IN DIRECTION OF SHEAR LOAD
DC1 THE STRUCTURAL ELEMENTS HAVE BEEN DESIGNED FOR THE FOLLOWING LIVE LOADS A1. ALL WORKMANSHIP AND MATERIALS SHALL COMPLY WITH BEST PRACTISE ALUMINIUM 5D PITCH BETWEEN BOLTS
IN ACCORDANCE WITH AS 1170.1: LIVE LOAD REDUCTIONS ARE NOT APPLICABLE. FABRICATION AND THE CURRENT AUSTRALIAN STANDARD AS 1664. 5D EDGE DISTANCE FROM END OF ELEMENT
ELEMENT UDL CONCENTRATED A2. ALUMINIUM SECTIONS SHALL COMPLY WITH AS 1734, AS 1886 OR AS 1867. 13D MINIMUM OVERALL ELEMENT DEPTH
ROOF 0.25 kPa 1.1KN A3. ALL WELDING SHALL COMPLY WITH AS 1665.
INTERNAL FLOORS 1.5kPa A4. ALL WELDING SHALL BE CARRIED OUT USING ARGONGAS SHIELDING. WELD
DECK 2.0kPa MINIMUM SPACING, EDGE & END DISTANCES FOR NAILS AND SCREWS
CONSUMABLES SHALL BE COMPATIBLE WITH BOTH PARENT ALLOYS IN ACCORDANCE
THOROUGHFARES 4.0 kPa WITH AS AS 1665. FOR 6063-T6 USE 4043 FILLER WIRE. PLATE-TO-EXTRUSION ALLOYS
MINIMUM DISTANCE
SHALL BE WELDED USING APPROPRIATE FILLERS IN ACCORDANCE WITH WTIA
DC2 WIND LOADS HAVE BEEN DETERMINED IN ACCORDANCE WITH AS 1170.2 BASED ON: TECHNICAL NOTES WHERE NOT COVERED BY AS 1665.
IMPORTANCE LEVEL 2 SPACING TYPE HOLES FOR HOLES FOR
A5. ALL WELDS SHALL BE A MINIMUM 5mm CONTINUOUS FILLET WELD ALL ROUND,
REGION B NAILS NOT NAILS PREBORED SCREWS
UNLESS NOTED OTHERWISE.
ULTIMATE WIND SPEED 51 m/s PREBORED TO 80% DIA.
A6. ALUMINIUM EXTRUSIONS SHALL BE STRUCTURAL GRADE ALLOY:- EXTRUSIONS 6063-T6
SERVICEABILITY WIND SPEED 39.0 m/s END DISTANCE 20D 10D 10D
UNLESS NOTED OTHERWISE.
TERRAIN CATEGORY 1.5 EDGE DISTANCE 5D 5D 5D
A7. ALUMINIUM PLATE IS TO BE WROUGHT GRADE ALLOY 5083 H116.
ALONG-GRAIN SPACING 20D 10D 10D
A8. ALL STEEL AND STAINLESS STEEL BOLTS AND ALL OTHER FIXINGS MUST BE ISOLATED
DC3 EARTHQUAKE LOADING HAS BEEN DETERMINED IN ACCORDANCE WITH AS 1170.4 BASED CROSS-GRAIN SPACING 10D 3D 3D
FROM ALUMINIUM USING NYLON OR SIMILAR APPROVED PACKERS/GASKETS, AND
ON: WASHERS WITH SHANK COLLARS.
ACCELERATION COEFFICIENT 0.06 A9. SHOP DETAIL DRAWINGS ARE TO BE SUBMITTED TO THE ARCHITECT AND ENGINEER
SITE FACTOR 1 FOR REVIEW. APPROVAL IS TO BE OBTAINED FROM THE COUNCIL, THE ARCHITECT AND
IMPORTANCE LEVEL 1 THE ENGINEER, PROIR TO COMMENCING FABRICATION.
STRUCTURE TYPE
DESIGN CATEGORY EDC1
DC4 FIRE RESISTANCE LEVELS OF STRUCTURAL ELEMENTS HAVE BEEN TAKEN AS FOLLOWS: TEMPORARY WORKS:
ELEMENT FRL (mins)
COLUMNS -/-/-
BEAMS -/-/- T1. MAINTAIN THE WORKS IN A SAFE CONDITION. ENSURE STRUCTURES ARE NOT
WALLS -/-/- OVER-STRESSED AT ANY TIME. TEMPORARY ROAD SURFACES SHALL BE TRAFFICABLE
AT ALL TIMES. POTHOLES ETC SHALL BE MONITORED AND REPAIRED.
DC5 DETERMINATION OF DESIGN LOADING FOR NON-STRUCTURAL ELEMENTS SUCH AS
CEILING AND CLADDING SYSTEMS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR
T2. CONTRACTOR'S RPEQ TO CERTIFY DESIGN AND CONSTRUCTION FOR TEMPORARY
DC6 FLOOD LOADING HAS BEEN DETERMINED IN ACCORDANCE WITH AS 5100 WITH NOMINAL WORKS: STRUTS, PROPPING, FORMWORK STRIPPING AND PROPPING PROCEDURES, TIE
FLOOD VELOCITY TO BE CONFIRMED BY HYDRAULIC REQUIREMENTS AS FOLLOWS: BACKS, EXCAVATION SHORING, PROTECTION WORKS, DE-WATERING SYSTEMS,
-V100 = 1m/s. FORMWORK, EARLY LOADING OF STRUCTURES AND THE LIKE.
© THIS DRAWING IS PROTECTED ASSOCIATED CONSULTANTS PROJECT DRAWING TITLE
UNDER COPYRIGHT IN
ACCORDANCE WITH
AGREEMENT BETWEEN LONG
VIEW CONSULTING ENGINEERS
NOOSA JETTY BUILDERS
JoB No: 1291
Address:
Long View PROPOSED NEW JETTY
43 WYUNA DRIVE, NOOSAVILLE QLD
STRUCTURAL NOTES SHEET
Pty. Ltd. AND THE CLIENT AS
L Consulting Engineers Pty. Ltd.
REVISIONS
NAMED HEREIN. EXCLUSIVE 43 WYUNA DRIVE, NOOSAVILLE.
USE IS GRANTED UNDER THE LOT 21 ON N1057.6
AGREEMENT ONLY FOR THE
PROJECT. THIS DRAWING SHALL
Client: IAN MARTIN V Post:
ABN:
PO Box 963 Cooroy QLD 4563
98 867 060 985
DRAWN
S.T.
CHECKED
F.M.
APPROVED DATE
10/07/2020
SCALE BAR DRAWING SCALES
1:1
DRAWING SIZE
A1 ORIGINAL
NOT BE CONSTRUCTED UNLESS Mobile: 0414 681 676
DESCRIBED AS "CONSTRUCTION 1 CONSTRUCTION ISSUE C1 F.M. Email: [email protected] DESIGNED CHECKED RPEQ / Cert. PROJECT NUMBER DRAWING NUMBER REVISION
ISSUE". Internet: www.longviewconsulting.com.au
No. DESCRIPTION REV. APP. F.M. F.M. 19951 20.001-003 S02 C1
Page 3
NOTES:
73°50'40"
30.410
1. UNLESS NOTED OTHERWISE, ALL TIMBER SHALL BE DURABILITY
LOT: 23 CLASS 1 OF APPROVED SPECIES AND HAVE STRESS GRADE OF F14.
LOT: 21
RP: N10576 DO NOT FIX JETTY
RP: N10576
261°48'
30.425
TO EXISTING 2. UNLESS NOTED OTHERWISE, ALL CONSTRUCTION SHALL COMPLY WITH
AREA: 621 m²
REVETMENT WALL THE ENVIRONMENTAL PROTECTION AGENCY'S OPERATIONAL POLICY
LOT: 22 ~17360 EXISTING
RP: N10576 "BUILDING AND ENGINEERING STANDARDS FOR TIDAL WORKS".
REVETMENT
1000
~3660 5.675 1500
WALL 3. ALL STAINLESS STEEL BOLTS, SCREWS, RODS, ETC. SHALL BE APPROVED
164°49'
9.140 MARINE GRADE 316.
7.715 166°27'
171°52' ALL OTHER STEEL WORK, INCLUDING NUTS, BOLTS, WASHERS,
AND SCREWS SHALL BE HOT DIP GALVANIZED OR STAINLESS STEEL.
P1
REFER TO ELEVATION B1
3000
P1
FOR H.A.T. AT 4. TOP OF PILES SHALL BE SEALED AND FULLY CAP FLASHED OR RINGED WITH
2424
3000
REVETMENT WALL 1500 AN ALUMINIUM ALLOY OR STAINLESS STEEL BAND.
1500 J1 HANDRAIL TO DETAIL.
1500 1500 RIGID HANDRAIL TO
5. DIMENSIONS AND LEVELS SHALL NOT BE SCALED FROM THESE DRAWINGS.
COMPLY WITH NOOSA
P1
P1
COUNCIL REGULATIONS.
8207
B1 6. ALL LEVELS SHOWN ARE APPROXIMATE ONLY.
2424
1500 J1 ALL LEVELS SHALL BE CONFIRMED ON SITE BY THE BUILDER PRIOR TO
CONSTRUCTION WORKS.
P1
12000
MILLBOARD DECKING
7. TIDAL LEVELS REFERENCE MARITIME SAFETY QLD. PUBLISHED TIDE DATA.
P1
B1 BY OTHERS
FLOOD LEVEL RECORD FROM BOM DATA.
2424
FIXED TO MANUF. SPEC.
PROJEC
BOUNDA
J1
WAA
WAA
WAA
B1 35 JETTY LOADING CRITERIA:
WA A
00 KAYAK STEP
TED
P1
P1
RY
TO DETAIL.
JETTY LIVE LOADS: = 2.0 kPa
2420
B2
PROJECTED
23 400
BOUNDARY
ALUMINUM SEAT MOORED VESSEL (MAX.)
P1
B3
TO DETAIL P1 LENGTH: = 5.0m
1500
1200
1200
J1
WEIGHT: = 1500 Kg.
B2 BERTHING VELOCITY: = 0.5m / Sec.
P1
P1
3900 4100 150 3800
TYP.
150
TYP.
FISH
FISH
EXISTING JETTY FRAMING PLAN
1:100
10800
FRAMING SCHEDULE
PIERS:
8000
8000
P1 - 200Ø HWD. PIER, H6 TREATED.
BEAMS:
B1 - 150 x 75 F14 HWD. BEARER, H6 TREATED.
B2 - 225 x 75 F14 HWD. BEARER, H6 TREATED.
B3 - 2/225 x 75 F14 HWD. BEARER, H6 TREATED.
JOISTS:
WAA J1 - 150 x 75 F14 HWD. JOISTS AT 450 CRS, H6 TREATED.
IDOR
ION CORR
WAA NAVIGAT ALL EXPOSED TIMBER SHALL BE H6 TREATED.
NAVIGATION CORRIDOR
NOOSA RIVER DO NOT FIX JETTY
TO EXISTING
HANDRAIL TO DETAIL. REVETMENT WALL
RIGID HANDRAIL TO
COMPLY WITH NOOSA
JETTY SITE & WATER ALLOCATION PLAN COUNCIL REGULATIONS. TOP OF WALL
1:100 RL 1.20m AHD
N
DECK
RL 1.20m H.A.T.
LEGEND
RL 0.42m AHD
P1
WAA DENOTES PROPOSED WATER ALLOCATION AREA
P1
P1
P1
P1
P1
BASED ON EPP/2016/2088.V.5.01 RULES EXISTING
REVETMENT WALL
P1(b)
P1
P1
AWAA DENOTES ADJACENT PROPERTY WATER STONE PITCHING
ALLOCATION AREA PRESERVED. SEABED
SEABED
FISH DENOTES FISH HABIT MANAGEMENT AREA
TYP.
TYP.
3000
3000
JETTY SIDE ELEVATION JETTY RIVER ELEVATION
1:50 1:50
© THIS DRAWING IS PROTECTED ASSOCIATED CONSULTANTS PROJECT DRAWING TITLE
UNDER COPYRIGHT IN
ACCORDANCE WITH
AGREEMENT BETWEEN LONG
VIEW CONSULTING ENGINEERS
5
4
CONSTRUCTION ISSUE
CONSTRUCTION ISSUE
C5
C4
F.M.
F.M.
NOOSA JETTY BUILDERS
JoB No: 1291
Address:
Long View PROPOSED NEW JETTY
43 WYUNA DRIVE, NOOSAVILLE QLD
SITE PLAN, FRAMING PLAN, ELEVATIONS
Pty. Ltd. AND THE CLIENT AS
L Consulting Engineers Pty. Ltd.
REVISIONS
NAMED HEREIN. EXCLUSIVE 43 WYUNA DRIVE, NOOSAVILLE.
USE IS GRANTED UNDER THE
3 CONSTRUCTION ISSUE C3 F.M. LOT 21 ON N1057.6
AGREEMENT ONLY FOR THE
PROJECT. THIS DRAWING SHALL 2 CONSTRUCTION ISSUE C2 F.M. Client: IAN MARTIN V Post:
ABN:
PO Box 963 Cooroy QLD 4563
98 867 060 985
DRAWN
S.T.
CHECKED
F.M.
APPROVED DATE
19/10/2020
SCALE BAR DRAWING SCALES
1:100, 1:50
DRAWING SIZE
A1 ORIGINAL
NOT BE CONSTRUCTED UNLESS Mobile: 0414 681 676
DESCRIBED AS "CONSTRUCTION 1 CONSTRUCTION ISSUE C1 F.M. Email: [email protected] DESIGNED CHECKED RPEQ / Cert. PROJECT NUMBER DRAWING NUMBER REVISION
ISSUE". Internet: www.longviewconsulting.com.au
No. DESCRIPTION REV. APP. F.M. F.M. 19951 20.001-003 S03 C5
Page 4
KICK BOARD 1-M16 BOLT S.S. KICK BOARD MILLBOARD MILLBOARD KICK BOARD MILLBOARD MILLBOARD
BY BUILDER J1 TO B1/B2 BY BUILDER DECKING DECKING BY BUILDER DECKING DECKING
TYPICAL.
MIN.
100
J1 J1 J1
B1
/B
J1
B3
2
B1
25 B1/B2 1-M16 BOLT S.S.
/B
1-M16 BOLT S.S. 1-M16 BOLT S.S.
B1/B2 TO P1 NOTCH J1 ENDS
2
RECESS J1 TO B1/B2
B3 TO P1
B1
25 TYPICAL. 25 1-M16 BOLT S.S.
TYPICAL. TYPICAL.
/B
80 PER J1 TO P1
RECESS RECESS
2
25 MIN. TYPICAL.
RECESS JOIST J1(A) SHALL
BEAR ON J1(B)
P1
P1
P1
P1
JOIST & BEAM TO PILE BEAM TO PILE BEAM B3 TO PILE JOIST TO BEAM EXTERNAL JOIST LAP
TYPICAL DETAIL TYPICAL DETAIL TYPICAL DETAIL TYPICAL DETAIL TYPICAL DETAIL
1:10 1:10 1:10 1:10 1:10
MILLBOARD MILLBOARD
DECKING DECKING
J1 J1 J1
80
MIN. 1-M16 BOLT S.S. 1-M16 BOLT S.S.
J1 TO B1/B2 J1 TO B1/B2
/ B2 PER J1 CONNECTION
/B2 TYPICAL.
B1 1
1-M16 BOLT S.S. TYPICAL.
B
J1 J1 TO B1
TYPICAL.
NOTCH OUT MIN. 25mm
DEEP SEAT AT BEARER INTERNAL JOIST LAP INTERNAL JOIST TO BEAM
& JOIST CONNECTIONS.
TYP.
TYPICAL DETAIL TYPICAL DETAIL
1:10 1:10
J1
1-M16 BOLT S.S. EDGE OF
B1 TO P1 DECKING /
TYPICAL. KICK BOARD 1-M16 BOLT S.S.
P1
B2 TO P1
TYPICAL.
J1
1 /B2
B
P1
1-M16 BOLT S.S. INSTALL
J1 TO P1 B1 SECOND
TYPICAL. B1
B2 IF M16 BOLT INSTILLATION
B1 TO P1 IS UNACHIEVABLE
INSTALL PROVIDE 1-M16 COACH SCREW S.S.
B1 TO P1, 150 EMBEDMENT
P1
B2 FIRST
TYPICAL.
JOIST OVER OMITTED FOR CLARITY
SKEW BEAM INTERSECTION TO PIER
PILE TO BEAM TO JOIST - TYPICAL VIEW TYPICAL DETAIL
1:10 1:10
© THIS DRAWING IS PROTECTED ASSOCIATED CONSULTANTS PROJECT DRAWING TITLE
UNDER COPYRIGHT IN
ACCORDANCE WITH
AGREEMENT BETWEEN LONG
VIEW CONSULTING ENGINEERS
NOOSA JETTY BUILDERS
JoB No: 1291
Address:
Long View PROPOSED NEW JETTY
43 WYUNA DRIVE, NOOSAVILLE QLD
JETTY FRAMING DETAILS - SHEET 1
Pty. Ltd. AND THE CLIENT AS
L Consulting Engineers Pty. Ltd.
REVISIONS
NAMED HEREIN. EXCLUSIVE 43 WYUNA DRIVE, NOOSAVILLE.
USE IS GRANTED UNDER THE LOT 21 ON N1057.6
AGREEMENT ONLY FOR THE
PROJECT. THIS DRAWING SHALL 2 CONSTRUCTION ISSUE C2 F.M. Client: IAN MARTIN V Post:
ABN:
PO Box 963 Cooroy QLD 4563
98 867 060 985
DRAWN
S.T.
CHECKED
F.M.
APPROVED DATE
06/10/2020
SCALE BAR DRAWING SCALES
1:10
DRAWING SIZE
A1 ORIGINAL
NOT BE CONSTRUCTED UNLESS Mobile: 0414 681 676
DESCRIBED AS "CONSTRUCTION 1 CONSTRUCTION ISSUE C1 F.M. Email: [email protected] DESIGNED CHECKED RPEQ / Cert. PROJECT NUMBER DRAWING NUMBER REVISION
ISSUE". Internet: www.longviewconsulting.com.au
No. DESCRIPTION REV. APP. F.M. F.M. 19951 20.001-003 S04 C2
Page 5
A
50 x 50 x 4 -
ALUMINUM ANGLE
BUTT JOINT TO BOX SIDE FACE 450 CRS.
CFW ALL ROUND
J1
J1
JOIST ZONE 10 PLATE CLEATS
140 x 35 HWD. DECKING
STEP AND FASCIA CFW TO BOX
B2
2-M12 x 50Lg. 75x75x4 BOX x 500 Lg.
FIXED TO BUILDERS
S.S COACH SCREWS 6 END PLATE
400
DETAILS
CFW TO BOX
50x50x4 BOX
50x50x4 BOX
10 CAP PLATE, 175 Sq.
10 AL. END PLATE CFW TO BOX
CFW TO BOX 2-M12 BOLTS
510 MAX. 950 MITRE JOINT SITE DRILL BOLT
CFW ALL ROUND HOLES TO SUIT
A SECTION
- 1:10
KAYAK STEP
TYPICAL SECTION DETAIL
1:10
50x50x4
250
AL. BOX
J1
O
50
VE
x5
R
0x
4
AL
.
J1
O
700
VE
R
A
-
6 CAP PLATE
50x50x4 CFW TO BOX
AL. BOX SEAT TO BE A FULLY
75x75x4 BOX WELDED ALUMINUM FRAME.
PERPENDICULAR BUTT & MITRE JOINTS,
1950
TO JOISTS CFW ALL ROUND.
50
x5
0x
2000
4
420
AL
140 x 25 HWD.
175 825 825 175
.
DECKING TO FORM
DECKING STEP
SEAT & BACKREST.
B2 OVER
FIXED TO BUILDERS 6
900
750
DETAILS
50x50x3 BOX 1
6 END PLATE
75x50x4 BOX
75x50x4 BOX
75x50x4 BOX
10 PLATE CLEAT CFW TO BOX
J1
450
50x50x4 MIN. 100 H x 190 W
O
VE
AL. BOX CFW TO BOX
BOX
R
2-M12 x 50Lg.
4
S.S COACH SCREWS
75x50x
50
250
x5
185
J1
J1
J1
0x
J1
J1
J1
4
75
O
O
AL
VE
VE
.
R
R
MITRE JOINT
75x50x4 BOX CFW ALL ROUND
10 END PLATE
CFW TO BOX
2-M12 x 50Lg.
S.S COACH SCREWS
DOUBLE KAYAK STEP ALUMINUM SEAT ALUMINUM SEAT
TYPICAL PLAN DETAIL TYPICAL ELEVATION (WATER EDGE) TYPICAL SECTION
1:10 1:10 1:10
© THIS DRAWING IS PROTECTED ASSOCIATED CONSULTANTS PROJECT DRAWING TITLE
UNDER COPYRIGHT IN
ACCORDANCE WITH
AGREEMENT BETWEEN LONG
VIEW CONSULTING ENGINEERS
NOOSA JETTY BUILDERS
JoB No: 1291
Address:
Long View PROPOSED NEW JETTY
43 WYUNA DRIVE, NOOSAVILLE QLD
JETTY FRAMING DETAILS - SHEET 2
Pty. Ltd. AND THE CLIENT AS
L Consulting Engineers Pty. Ltd.
REVISIONS
NAMED HEREIN. EXCLUSIVE 43 WYUNA DRIVE, NOOSAVILLE.
USE IS GRANTED UNDER THE LOT 21 ON N1057.6
AGREEMENT ONLY FOR THE
PROJECT. THIS DRAWING SHALL
Client: IAN MARTIN V Post:
ABN:
PO Box 963 Cooroy QLD 4563
98 867 060 985
DRAWN
S.T.
CHECKED
F.M.
APPROVED DATE
10/07/2020
SCALE BAR DRAWING SCALES
1:10
DRAWING SIZE
A1 ORIGINAL
NOT BE CONSTRUCTED UNLESS Mobile: 0414 681 676
DESCRIBED AS "CONSTRUCTION 1 CONSTRUCTION ISSUE C1 F.M. Email: [email protected] DESIGNED CHECKED RPEQ / Cert. PROJECT NUMBER DRAWING NUMBER REVISION
ISSUE". Internet: www.longviewconsulting.com.au
No. DESCRIPTION REV. APP. F.M. F.M. 19951 20.001-003 S05 C1