                                                                                 Advanced Enviro-septic Design Calculator V8.6 ©

                                                                    "Always the BEST Option" until site and soil conditions rule it out.
                  Site
                         90 Beach Rd Noosa North Shore                                                                         State    Qld               Post Code                          4655
                 Address
                  Client
                                                                                                                                                      Date of Site Visit
                  Name
                                                                                                                                                        Designer Lic
                Designers                                                                           Designers Ph
                                                                                                                                                           Number
                 Name                                                                                 Number
                   Lic                                                                                                                                   (eg.QBCC)
                                                                                                     Plumber Ph                                        Plumb / Drainer
                Plumber
                                                                                                       Number                                           Lic Number
                  Name
                 Council                                                                            Designers AES
                                                                                                                                                            Date                21/08/2019
                  Area                                                                               Cert Number
                            This Calculator is a guide only, receiving soil classification, surface water, water tables and all other site constraints addressed by the qualified designer.

                                      System Designers site and soil calculation data entry                                                   IMPORTANT NOTES

Enter the AES litre/meter loading rate, "30" for Advanced Secondary or "38" Secondary                     30        >> This design is for an ADVANCED SECONDARY system

                                                          Is this a new installation    Y or N            y         >> Minimun single vent size is 80mm or 2 x 50mm house vents

                                                                           Number of person               8                a septic tank outlet filter is NOT RECOMMENDED

                                            Daily Design Flow Allowance Litre/Person/Day                 145

                                       Number of rows required to suit site constrants                    3         >> Longer AES runs are better than multiplule short runs.


 Infiltration surface Soil Category as established by site and soil evaluation. CATEGORY                  1

                     Design Loading Rate based on site & soil evaluation DLR (mm/day)                     30

                                                        Bore log depth below system Basel area            2         >> Min depth below basel area is 600 mm to establish water table or restrictive layer

                   Enter System footprint Slope in % for standard AES systems to calculate extension
                                                                                                   1                >> Some Councils have minimum falls to Land application areas ?

                              Is this design a gravity system with no outlet filter? Y or N               y         >> A House Vent & LOW VENT required on this system

                             PLEASE CHECK YOU HAVE FALL FROM TANK TO AES SYSTEM PIPES

                COMMENTS :- " The outcome must be important to everyone. "




                - Designers need to be familar with special requirements of Local Authorities. IE - Minimun falls from Septic tank outlets to Land application areas. etc



                - Plumbers are reminded to practice good construction techniques as per AS 1547 and as provided on AES installation instructions supplied with components.


                                               AES System Calculator Outcomes                                                                             AES dimensions

                                                          Total System load - litres / day (Q).          1160       l/d                                AES System           System Extension

                                               Min Length of AES pipe rows to treat loading              12.9       lm                  Lth m : (L)         15.6                   15.6

                                                   Number of FULL AES Pipe lengths per row                5         lths               Width m:(W)          1.80                   0.68
                                                                                                                                       Sand Depth
                                                 Total Capacity of AES System pipe in Litres            3180        ltr.                                    0.75                   0.15
                                                                                                                                            :
                                       AES Additional infiltration extension required                    10.6       m2                    Area m2           28.1                   10.6
                 DO YOU WISH TO USE CUT LENGTHS OF PIPE IN THIS DESIGN? (ENTER Y)

                              IF YOU WISH TO USE A TRENCH EXTENSION DESIGN OPTION ENTER "Y"                                                   Enter Custom Width in metre

                   AES INFILTRATION FOOT PRINT AREA -                    L = Q / ( DLR x W)            Length                 Width            Minimum AES foot print required .

                                                      for this Basic Serial design is                    15.6         x        2.48            =            38.7            m2 total




                  Code                           AES System Bill of Materials.                                                                     Chankar Environmental Use Only

                AES-PIPE                           AES 3 mtr Lths required                                15        lths

                  AESC                             AESC Couplings required                                12        ea

                  AESO                              AESO Offset adaptors                                  6         ea

                AESODV                             AES Oxgen demand vent                                  1         ea

                AES-IPB                       AES 100mm Inspection point base                             2         ea

                 AES Equ                          AES Speed Flow Equaliser                                          ea

               AES DESO                             Double Offset Adaptors                                          ea

                                    TOTAL SYSTEM SAND REQUIRED (Guide Only)                               27        m3

                                     PLEASE email your AES CALC and Drawings to

                                     [email protected]                                                                                [email protected]
                > The AES Calculator is a design aid to allow checking of the AES components and configuration and is a guide only. Site and soil

                conditions referencing the AS 1547 standard are calculated and designed by a Quailified Designer.

                > Chankar Environmental has no responsibility for the soil evaluation, loading calculations or DLR entered by the designer for this calculator.

                > AES pipes can be cut to lenght on site. They are supplied in 3 meter lths only.

                                                                  AES-Design-V8.6-Calculator © Copy Right - Chankar Environmental pty ltd 14/3/2016

Used in these records

About this file

File size
1.5 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

3. Effluent Disposal Report.pdf · 1.5 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.