Council archive · source document
SUPERSEDED - Generally in Accordance - Plans - MCU22/0016.01
Plans and drawings: the text below has words only, no drawings.
Original PDF page 11, section 1. The text section number identifies this passage in the reader.
G F E D C B A
4,480 3,700 8,590 2,800 5,910 2,300
AFW conc REN AFW CS hood CS PW hood hood
DET-06
WD.703
UT
CTION C
HT LIM IT AT SE
8m HEIG
W31 PB PB W23
2,620
T.O.W R.L 17.180 GREEN ROOF PLANTER
ENTRY
STAIR VOID VOID DET-08
WD.705
PLANTER T.O.W R.L 16.230
4,700
TF
UPPER LEVEL PB PB PB UPPER LEVEL
join
FFL 15.910 W09 W14 D06 FFL 15.910
LIVING
2,650
DECK W15 PB PB
W11 ROOM D03
join
T.O.W R.L 14.560
2,580
retractable W09 TF TF FOYER
awning 5 NGL
4
3
2 TF join
1 R:172
MAIN LEVEL ref. eng PB PB PB PB G:350 MAIN LEVEL
join
FFL 12.970 PB D12 FFL 12.970
a/c grill
AL
ZACS a/c grill iron iron iron
2,670
2,670
ROOM joint joint joint waterproof membrane/
2,350
W39 join join
PF
POOL DECK join
CRAFTS BLK BLK BLK drainage & protected
RWT termite barrier to BCA/AS
NGL
TD TF TF FT FT TF CS
LOWER LEVEL POOL W37
LOWER LEVEL
FFL 10.770 acrylic pool window FFL 10.770
BAL SF SF
fill SF
deck connection, ref. engineer
waterproof membrane/
NGL SF drainage & protected
termite barrier to BCA/AS
fill
SF
SECTION E
SCALE 1:100 @ A3
BA/C1 For Buliding Approval & construction
issue issue / amendment
22.02.23 LF AB JH
EXT. FINISHES LEGEND FCA fibre cement awning. PF compliant pool fencing
issue date
client
drawn by
Ingrid & Nick Hutton
AS aluminium screen. FC fibre cement ext. cladding. PW parapet wall.
project
AL aluminium louvres, refer sched. FG fascia gutter. PS patio slab. Hutton Plover St
location
ASD aluminium sliding door. FT1 floor tile (no refers to type). PV photovoltaic cells. 24 Plover St Peregian Beach
AFD aluminium framed door. fire fireplace RWT rain water tank. SECTION E
AFW aluminium framed window. flue flue kit SBJ silicone butt jointed glass. Aboda Lee Foster • director Scott Falconer • director
Design p - 0424 620 247 p - 0431 267 157
Group e - [email protected]
BA sun control battens, refer detail. GS garage slab. SP structural post, refer engineer. the aboda design group trust
e - [email protected]
Level 2 1794 David Low Way Coolum Beach,
ABN 56 266 884 746 Q. 4573. PO box 2449 Noosa Heads Q 4567
BAL1 balustrade-(no refers to type). HWS hot water service. SF structural footing, ref. eng. t/a aboda design group • BSA License -150580097 • www.aboda.com.au
• This drawing is to be read in conjunction with engineers drawings & reports • Construction
BLK masonry blockwork. HR handrail. TIM timber cladding. to comply with all relevant SAA & NCC Codes & standard Bldg By-law 1975 & as amended •
Copyright for design & drawings remain the property of the authors • Verify all dimensions on
site prior to commencement of any works • These drawings are not to be used for scaling.
NOOSA COUNCIL C carpet LPG LPG gas bottle. TD timber deck.
scale as shown @ A3 issue
concrete slab. NRG board
TF timber floor. drawing no.
GENERALLY IN ACCORDANCE CS NGL
BA/
MCU22/0016.01 4 APRIL 2023 DP
DS
down pipe.
driveway slab.
MR1
NGL
metal roof - (no refers to type).
natural ground line.
TFD
VER
timber framed door
vergola.
WD.603 C1
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
SUPERSEDED - Generally in Accordance - Plans - MCU22/0016.01.pdfRelated documentApplication case desk ↗
About this file
- File size
- 6.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.