Council archive · source document
SUPERSEDED - Generally in Accordance - Plans - MCU22/0016.01
Plans and drawings: the text below has words only, no drawings.
Original PDF page 5, section 1. The text section number identifies this passage in the reader.
NOOSA COUNCIL D G C
A B WD.602 C WD.605 D WD.601 E F G
GENERALLY IN ACCORDANCE
N 3° 16' 8" E
2,300 5,910 2,800 8,590 3,700 4,480
MCU22/0016.01 4 APRIL 2023
13.00
12
12.00
10.0
11.50
11.00
1
10.75
12.25
11.75
11.25
10.50
12.
9.75
0.25
.75
9.50
50
0
90°0'
33.561
hood
1 1
fall
conc
2,890
2,890
H DET-06
hood H
WD.605 STUDY approx manhole location, WD.605
ADDITIONAL PANEL
WD.703
hood not located by surveyor
BELOW
PV SYSTEM:
LOCATION
hood
2 2
2°13'20"
15.088
8.
E 00 E
WD.603 WD.603
ROOF
2,970
2,970
hood
BELOW
ENTRY
GREEN
ADDITIONAL PANEL
fall
6m REAR SETBACK
fall DP
ROOF
182°13'20"
PV SYSTEM:
3 3
LOCATION
15.088
A (below) A
WD.601 WD.601
entry gate PV SYSTEM: PANEL
F ARRAY TO UPPER F
WD.604 ROOF. 20kW WD.604
falls & drainage to GREEN
13" E
concrete roof, refer
hydraulic engineer. MASTER ROOF
N 8° 47'
(below) POOL
5,870
5,870
conc BED
BELOW BELOW
ADDITIONAL PANEL
DRIVEWAY 12
PV SYSTEM:
.75
LOCATION
BELOW
12
fall
.75
B B
WD.602 WD.602
approx sewer
4 house connection
location
4
1,410
1,410
hood (invert RL 7.32)
BIN STORE
5 33.561
270°0'
5
9.5
9.2
9.7
11.25
10.75
8.25
8.75
9.0
10.50
11.50
8.50
11.75
11.
10.25
0
5
5
0
0
0
2,300 5,910 2,800 8,590 3,700 4,480
G C
A B D
WD.602 C WD.605 D WD.601 E F G BA/C1
issue
For Buliding Approval & construction
issue / amendment
22.02.23 LF AB JH
EXT. FINISHES LEGEND FCA fibre cement awning. PF compliant pool fencing WALL LEGEND GENERAL LEGEND FLOOR FINISH LEGEND issue date
client
drawn by
D04 denotes door number Ingrid & Nick Hutton
AS aluminium screen. FC fibre cement ext. cladding. PW parapet wall. RC masonry blockwork FT1 FT2 Indicates extent of TILE
project
WINTER
SUN PATH AL aluminium louvres, refer sched. FG fascia gutter. PS patio slab. W04 denotes window number Hutton Plover St
RC pool shell/off form concrete location
RL 17.200 C Indicates extent of CARPET
Sett am
) ASD aluminium sliding door. FT1 floor tile (no refers to type). PV photovoltaic cells. denotes finished floor level 24 Plover St Peregian Beach
in g5 in g (7 90MM ext. timber frame
pm Ris
AFD aluminium framed door. fire fireplace RWT rain water tank. + RL 17.700 denotes spot level
TF TD ROOF PLAN
Indicates extent of TIMBER.
MER
SUM PATH N AFW aluminium framed window. flue flue kit SBJ silicone butt jointed glass. 70MM int. timber frame 50 step denotes change in level Aboda Lee Foster • director Scott Falconer • director
SUN Design p - 0424 620 247 p - 0431 267 157
pm Ris Indicates extent of GS DR Indicates extent CONCRETE Group e - [email protected]
in g5
.30
in g (6
.30
BA sun control battens, refer detail. GS garage slab. SP structural post, refer engineer. chs shs structural posts - refer fw
denotes floor waste the aboda design group trust
e - [email protected]
Level 2 1794 David Low Way Coolum Beach,
Sett am
) engineer. ABN 56 266 884 746 Q. 4573. PO box 2449 Noosa Heads Q 4567
denotes hard wired smoke
BAL1 balustrade-(no refers to type). HWS hot water service. SF structural footing, ref. eng. t/a aboda design group • BSA License -150580097 • www.aboda.com.au
BLK masonry blockwork. HR handrail. TIM timber cladding. hwsa
alarm BCA 3.7.2 min
300mm from wall FINISH CODE LEGEND • This drawing is to be read in conjunction with engineers drawings & reports • Construction
to comply with all relevant SAA & NCC Codes & standard Bldg By-law 1975 & as amended •
Copyright for design & drawings remain the property of the authors • Verify all dimensions on
site prior to commencement of any works • These drawings are not to be used for scaling.
5° denotes direction of roof fall denotes additional 'extent' information
C carpet LPG LPG gas bottle. TD timber deck.
(xxxxxxxx) scale as shown @ A3 issue
CS concrete slab. NGL NRG board
TF timber floor. MR denotes roof material denotes finish, refer 1000 drawing no.
BA/
XX
ROOF PLAN WD.205
series drawings for schedule
DP down pipe. MR1 metal roof - (no refers to type).
TFD timber framed door
driveway slab. natural ground line.
VER vergola. JXX
denotes item and number.
refer to Joiner for details
C1
SCALE 1:100 @ A3 DS NGL
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
SUPERSEDED - Generally in Accordance - Plans - MCU22/0016.01.pdfRelated documentApplication case desk ↗
About this file
- File size
- 6.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.