Generally in Accordance Plan - MCU22 0094.01 (As Published) · MCU22/0094.01
Plans and drawings: the text below has words only, no drawings.
Noosa Council documents
ROOF LEGEND
BC Barge Capping
BG/VG Box Gutter/ Valley Gutter
CB-C1 Metal roof sheeting
CV Chamber Vent
DP Downpipe (100 or 150Ø)
EG Eaves Gutter
KE Kitchen Exhaust - refer
mech. doc.
BRIDGE ARBOUR LBB Line of Building Below
OH Overhang
PV Photovoltaic Panels
RC Ridge Capping
SCR-4 100x50 Aluminium Battens
SCR-5 100x100 Aluminium Battens
A B C D SU Sump
VP Vent Pipe
SCR-5 WB Whirly Bird - refer mech.
doc.
Exhaust Riser
NOTES
1. Provide insulation and roofing
underlay to full extent of roof
as per energy efficiency report.
2. Refer to specification for full
product details and warranties.
3. Scribe flashings and capping to
roof sheet profile.
SCR-4
ARBOUR
BC BC SCR-5
DP DP
DP EG DP
EG
3,000
LBB
OH
ARBOUR
1 SU 1
600
OH
DP EG DP
1,370
LBB
RC
600
OH
LBB LBB EG
2 2
600
OH EG 600
R
OH LBB
C
G VP
3,104
/B
DP
LBB
VG
SU
C
SU EG
R
EG
CV DP DP
LBB
3 DP CV 3
600
OH
EG
LBB
CB-C1
16.0° Pitch C DP
R CB-C1
CB-C1 16.0° Pitch
VG
16.0° Pitch
G
600
/B
/B
OH
G
R
VG
C
PV PV PV PV PV PV PV
SU
WB ID
EGDP
WB WB WB WB
#Element
RC KE
PV PV PV PV PV PV PV
21,379
RC CB-C1 DP
16.0° Pitch
RC
VG
15,105
/B
G
R
C
BC VP
VP
WB DP
C
R
LBB
VG
RC CB-C1
/B
PV PV PV PV PV PV PV WB RC
16.0° Pitch
R
G
C
WB G
/B
G
LBB
V
PV PV PV PV PV PV PV EG
CB-C1 LBB
16.0° Pitch
1,500
OH
VP
R
C
C
R
VP DP DP EG DP DP
4 LBB SU
4
LBB
SU
1,500
600
1,800
OH
OH EG EG 600
OH
5 DP 5
DP DP EG DP LBB
DP EG DP
A B C D
NOOSA COUNCIL
GENERALLY IN ACCORDANCE
MCU22/0094.01 19 MARCH 2026
FOR INFORMATION ONLY
Contact Revision Project Stage Architect Project No.
(07) 3251 6900 01 For Coordination 11/08/2025 Noosa Early Learning Centre Building Application SC 1187-05 Roof Plan
02 Issue for Review 14/10/2025 Lot 4 Noosa
20 Prospect St, Fortitude Valley QLD 4006
A-WD-04.01 05
03 Issue for Coordination 22/10/2025
[email protected] Client Status Drawn Scale
04 Issue for Coordination 11/11/2025
Stockwell Development Group Pty Ltd Not For Construction TS 1:100 at A1
05 Issue for Coordination 4/02/2026
Document Set ID: 24555836 Elevation Architecture Pty Ltd ACN 606 170 807 © Copyright reserved this document is and shall remain the property of Elevation Architecture. Unauthorised use of this document in any form whatsoever is prohibited. All information to be printed in colour. Figured dimensions take precedence over scale dimensions. Contractors must verify all dimensions on site before commencing any work or making shop drawings. P:\Data 1\1187-05 Sanctuary Noosa Childcare Centre\5.3 Design Development\5.3.1 ArchiCAD\1187-05_Master DD 28.pln
Version: 1, Version Date: 23/02/2026 Print Date: 18 March 2026, 3:18 PM
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 1 page
Page 2
Noosa Council documents
ELEVATION & SECTION LEGEND
AC-2 Air Conditioner Condenser 2
B Bollard
BL Bollard Light
BLK Blockwork
BR Bike Rack
C1 Steel Column (refer structural doc.)
C2 Arbour Column (refer structural doc.)
CB-C1 Metal roof sheeting
CL Clothesline
CLD-1 FC Cladding type 1
CLD-2 FC Cladding type 2
DF Drinking Fountain
DP Downpipe
EG Eaves Gutter
FEN-1 Acoustic Timber Fence
FEN-2 Aluminium Timber Battens
FEN-3 Powdercoated Aluminium Fence
Boundary
Boundary
FHR Fire Hose Reel
FL Flood Light
LP Light Post
LRO Line of Roof Over
10.700 10.700 RW Retaining Wall
Storeys Storeys SCR-1 Aluminium Timber Battens
SCR-2 Vertical wire screen
CLD-2 CLD-1 WB SCR-3 Aluminium Battens
CLD-2 SU Sump
WB Whirly Bird
CLD-1 WH Window Hood
SCR-2 SCR-3
NOTES
7.700 C3 7.700
Roof Roof 1. Provide insulation and building paper to all
C3 C3 WL-2 C2 C2 external walls
2. Refer to Civil drawings for all correct ground
RLs
BL
BL BL DF
FHR DF
5.000 5.000 Refer to specification for full product details
Ground Floor Ground Floor and warranties.
Refer to schedules for material information.
1 North Elevation
- Scale 1:100
Boundary
Boundary
10.700 10.700
Storeys Storeys
LP
CLD-2
CLD-1
7.700 7.700
Roof Roof
WL-2 FL FL
TANK
FHR
BR
5.000 5.000
Ground Floor Ground Floor
2 South Elevation
- Scale 1:100
NOOSA COUNCIL
GENERALLY IN ACCORDANCE
MCU22/0094.01 19 MARCH 2026
FOR INFORMATION ONLY
Contact Revision Project Stage Architect Project No.
(07) 3251 6900 01 For Coordination 11/08/2025 Noosa Early Learning Centre Building Application SC 1187-05 Elevations (North and South)
02 Issue for Review 14/10/2025 Lot 4 Noosa
20 Prospect St, Fortitude Valley QLD 4006
A-WD-09.02 05
03 Issue for Coordination 22/10/2025
[email protected] Client Status Drawn Scale
04 Issue for Coordination 11/11/2025
Stockwell Development Group Pty Ltd Not For Construction TS 1:100 at A1
05 Issue for Coordination 4/02/2026
Document Set ID: 24555838 Elevation Architecture Pty Ltd ACN 606 170 807 © Copyright reserved this document is and shall remain the property of Elevation Architecture. Unauthorised use of this document in any form whatsoever is prohibited. All information to be printed in colour. Figured dimensions take precedence over scale dimensions. Contractors must verify all dimensions on site before commencing any work or making shop drawings. P:\Data 1\1187-05 Sanctuary Noosa Childcare Centre\5.3 Design Development\5.3.1 ArchiCAD\1187-05_Master DD 28.pln