KEY SITE REQUIREMENTS NOTES
CSD CAVITY SLIDING DOOR MFR METAL FLAT ROOF SD SMOKE DETECTOR · ALL TOILET DOORS TO HAVE LIFT OF HINGES · LIVABLE HOUSING DESIGN STANDARD 2022 COMPLIANT BATHROOM TO INCLUDE MINIMUM 820mm CLEAR OPENING, HOBLESS / STEP FREE ENTRY,
SITE 124.60m2 · RL'S ARE ASSUMED ONLY AND SHALL BE VERIFIED BY BUILDER PRIOR TO NO LIP GREATER THEN 5MM. REFER TO figure A4(3) ON QDC MP4.5 FOR FURTHER DETAILS. ENSURE RE-INFORCING IS DONE AS PER PART 6 OF
D DOOR MPR METAL PITCHED ROOF HT HOSE TAP COMMENCEMENT OF SITE WORKS LIVABLE HOUSING CODE.
GD GLASS DOOR CONCRETE FLAT ROOF G GAS POINT 73.55m2 · ALL BASINS & BATHS TO HAVE OVERFLOWS · ALL RELEVANT PAHTS & FLUSH TRANSITIONS AS REQUIRED BY NCC LIVABLE HOUSING CODE TO BE INSTATED TO CODE BY BUILDER. VOS WITH
FR SITE COVER: ALLOWED:
· PDR TO MEET REQUIREMENTS STATED IN THE 'LIVABLE HOUSING DESIGN STANDARD DESIGNER & CERTIFIER IF REQUIRED.
ACTUAL: 73.50m2
W WINDOW DP DOWN PIPE NGL NATURAL GROUND LEVEL 2022' · DOWN PIPES & ROOF DRAINAGE LOCATIONS ARE SUGGESTED ONLY AND BUILDER SHOULD ENSURE ADEQUATE STORMWATER FALL & DRAINAGE
· PDR TO HAVE MECHANICAL VENTILATION AS REQUIRED
FG FLOOR GULLY RH RAINHEAD FGL FINISHED GROUND LEVEL GFA: ALLOWED: 216.80m2 · ALL BASINS & BATHS TO HAVE OVERFLOWS · DRAINAGE SHOULD BE CONCEALED WITHIN SLAB WHERE NOTED.
ACTUAL: 194.48m2 · FOR ALL LANDSCAPING REFER TO LANDSCAPING CONSULTANTS DETAILED DRAWINGS · FOR ALL WET AREAS, SET DOWN FLOOR CONSTRUCTION TO PROVIDE TILED FLOOR FLUSH WITH ADJOINING FFL, FALL TO WASTE, DROP SHOWER
PD PLUMBING DUCT FALL DIRECTION RL FINISHED LEVEL
N
3.6
113 6
BLANK OUT °50
'
800
1
PD
3.
5'
OVEN DP X2
4.3
113 87
800
STACK
23°
°50
COOKTOP '
SINK
C'BRD
A 9.5 KITCHEN / DINING PANTRY
TIMBER LINE OF PELMET
LINE OF PELMET FRIDGE ABOVE
700
90°0'
180°0'
ABOVE 2700 CEILING
DP X2
2.3
W20
0 DINING TABLE OFF PLANTER
.55
KITCHEN ISLAND
PDR 11
FG
00°0'
STORAGE
2.6
RL
CISTERN
W16
STAIRS TILES
8
2400 CEILING
LIFT HT
9 720 CSD
10 VOID LINE OF PELMET
11 ABOVE
12
13
14 GLASS BALLUSTRADE IN
15
16
17
ACCORDANCE WITH AS1288 W17
DN
SD LINE OF PELMET
LIVING
3000 FLOOR TO FLOOR ABOVE TIMBER
17 [email protected] PLINTH
2700 CEILING
4
STORAGE
FEATURE
133
W19 3
2 1
UP STONE WALL
LINE OF PELMET 4
ABOVE 5 SPIRAL
FG
°5'
203 5
0
6 STAIRS
8.4
PLANTER HT
150
7
8 D5
16.
087 TERRACE W18
700
FG
293
°50
00
TILES
'
1.5 700
R L1
500
3100 FLOOR TO FLOOR
17 [email protected]
TERRACE GLASS
700
BALLUSTRADE IN
ACCORDANCE
WITH AS1288 LINE OF
LEVEL OVER
A
NOOSA COUNCIL
APPROVED PLAN
51983.3225.24 29 JUNE 2026
LEVEL 3 PLAN
PAUL CLOUT DESIGN GENERAL NOTES:
Suite 3, 44 MARY STREET, NOOSAVILLE
CLIENT NAME: Ptasznik, Rainer & Kate
Use written dimensions only. DO NOT scale drawings. Contractors to verify all
PO BOX 152, NOOSAVILLE, QLD 4566. dimensions on site prior to commencing works. Site location is Category W41 SITE ADDRESS: Unit 14-30, Hasting St
BSA LICENCE: 1066417 or to engineer's requirements. These drawings are to be read in conjunction SCALE: 1:100 ON A3
with engineer's design and details, the accompanying building specification and DRAWING TITLE: LEVEL 3 PLAN
schedule of finishes. If in doubt, please request clarification. DO NOT ASSUME. DRAWING DATE: 13/05/2026
PH: (07) 5440 5388 STAGE: COUNCIL DRAWINGS DRAWING No. 5.0
[email protected] @COPYRIGHT PAUL CLOUT DESIGN PTY LTD.
www.paulclout.com
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Compiled Approved Plans - 51983 3225 24 (AS PUBLISHED).pdfRelated documentApplication case desk ↗
About this file
- File size
- 76.2 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.