Original source · versioned page text
5.0 Planning Report Lot 15 Venture Drive
Attached to the e-mail MCU16/0087 & OPW16/0159 Development Application.
Division 13 – Driveways and Parking Code
column 1 column 2
Specific Outcomes P Probable solutions (if code assessable)
14.113 General
O1 Vehicular access does S1.1 Vehicular access is located and designed
not adversely impact on safety, in accordance with AUSTROADS- Guide to
capacity and operations of the Traffic Engineering Practice requirements for
existing or planned road sight distance and Section 3 of AS2890.1
network, the proposed Parking Facilities;
driveway, cycleways or AND
22
pedestrian pathway systems. S1.2 Only one footpath crossing is provided ;
AND
S1.3 Driveways, other than within any
setback have a maximum grade in
accordance with Section 3 of AS/NZS 2890.1
O2 Driveways S2.1 Design of the driveway across the Complies – The proposed
and crossovers— footpath is in accordance with Council’s development will comply with
a) are suitable and safe for Standard Drawings 9002 or 9005 as this requirement, please refer
their intended use; and appropriate for the particular type of to attached site plan and
b) match Council development as annotated on the drawings; engineering drawings reflecting
infrastructure. AND these details of compliance.
S2.2 Driveways are designed and Complies – The driveway is
constructed in accordance with Council designed in accordance with
Standard Drawings 9014, 9019, 9020, 9021, Council Standard Drawings
as appropriate for the particular type of 9014, 9019, 9020, 9021 to be
development as annotated on the drawings; consistent for the particular
AND type of development as
annotated on the drawings
S2.3 The change in grades in the driveways
and ramps is in accordance with Section 3 of Complies – Please refer to
AS2890.1 Parking Facilities. attached Design Drawings
O3 In commercial zoned S3.1 Design of multi-tenanted developments N/A - The proposed
areas, the number of in commercial zoned areas include shared development is not located
driveways across pedestrian driveways and parking areas; within a commercial zone.
footpaths is minimised. AND
S3.2 Driveways are located so they abut
existing driveways of adjoining development
where practicable and reciprocal easements
are created to reduce the sealed driveway
width.
O4 Vehicular access does S4.1 Footpath and kerb crossings are located Complies - The proposed
not adversely impact on the clear of existing stormwater inlet structures, development driveways and
capacity, operations and water and sewerage infrastructure fittings, any crossovers comply. Please
maintenance of the existing other exiting utility infrastructure, existing refer to attached Design
infrastructure; landscaping and vegetation. drawings for details.
AND
Complies - Existing vegetation
O5 Vehicular access does S5.1 No solution provided within the road reserve will be
not adversely impact on the retained to enhance proposed
integrity of existing onsite landscaping, except
landscaping or native where provision is made for
vegetation. the driveway access points.
Building Suncoast Green Page 18
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.