Original source · versioned page text
5.0 Planning Report Lot 15 Venture Drive
Attached to the e-mail MCU16/0087 & OPW16/0159 Development Application.
colum column 2
n1 Acceptable solutions (if self
Specific assessable) Probable solutions
O5 Outcomes
The provision of (if codeprovided
S5.1 Landscaping assessable)
which allows Complies – Please refer to
landscaping is to a satisfactory adequate visibility for casual surveillance attached Design Drawings
standard ensuring that it does not of public and semi-public spaces, including and landscape plans for
lead to opportunities for entrances and exits to sites and buildings, details.
concealment and possible assault by:
sites. a) planting trees which have clean
trunks to a height of at least 1.8 m;
and
b) appropriately spacing shrubs at 1.2m
horizontal centres, with a maximum
height of 0.75m, to avoid clumping
and to retain sightlines. Complies – Please refer to
S6.1 Street trees and trees in carparking attached Design Drawings
O6 Street trees and plantings areas achieve a maximum of 900mm and landscape plans for
in towns and villages, carparks clear trunk height for a 2.0m high tree at details.
and other areas where potential planting and are able to attain a clear
conflicts with vehicles and trunk height of 1900mm on maturity; AND Complies – Please refer to
pedestrians are evident, are S6.2 All scrub planting to be a maximum attached Design Drawings
planted so as to maximise height of 700mm from the road pavement and landscape plans for
vehicle and pedestrian safety. (not top of kerb). details.
Services and utilities
O7 All landscaping works S7.1 Plant species used in landscaping N/A
maintain adequate safe distance adjacent to substations, or adjacent to or
from services and utilities including on electricity transmission line easements,
substations, overhead powerlines, are less than 4m high at maturity and do
power poles and transformers, not encroach within 3m of a substation
street lamps, stormwater boundary;
catchment pits, and underground OR
services and utilities. S7.2 For trees higher than 4m, trees are
planted at a distance from any part of an
electricity transmission line at least equal
Figure 14-17
to the expected height of the tree at
maturity (see Figure 14-17); AND
S7.3 For power lines that connect to a
premises, the height of plant species at
maturity provides for a 2m clearance
below the power line; (see Figure 14-18)
AND
S7.4 Trees and large scrubs are
located a minimum of—
a) 5m from electricity poles and pillars;
Figure 14-18 b) 4m from street lamps;
c) 2m from stormwater catchment pits;
and
d) 2m from underground services and
utilities; AND
S7.5 Plants are located to enable
tradespersons to access, view and
inspect service meters, such as water
and electricity meters;
AND
S7.6 Root barriers are installed around
trees that are located within 3m of any
infrastructures or that have potentially
invasive roots.