Swmp · MCU22/0058
DRAINS Modelling Results Project number: 20220078 Calculations: B. Parry Street Address: 6 Wyandra Street Locality: Noosa Heads, Noosa Shire Council Date: 24/06/2022 Wyandra Street A.E.P Qchange (%) Qexisting (m³/s) Qproposed (m³/s) Qchange (m³/s) 1EY 0.016 0.018 0.002 13% 50% 0.019 0.02 0.001 5% 0.2 EY 0.028 0.03 0.002 7% 10% 0.036 0.036 0 0% 5% 0.041 0.041 0 0% 2% 0.047 0.047 0 0% 1% 0.051 0.052 0.001 2% Wyandra Street A.E.P Qchange (%) Qexisting (m³/s) Qmitigated (m³/s) Qchange (m³/s) Prelim Attenuation Sizing 1EY 0.016 0.015 -0.001 -6% Slimline 4,000L 50% 0.019 0.017 -0.002 -11% Surface Area 2.5515 0.2 EY 0.028 0.025 -0.003 -11% 2.15m total height 10% 0.036 0.03 -0.006 -17% 53mm low flow outlet at base 5% 0.041 0.037 -0.004 -10% 100mm high flow outlet at 2.05m 2% 0.047 0.045 -0.002 -4% 1% 0.051 0.051 0 0%