Council archive · source document
A-WD-04.01-05-Roof Plan · MCU22/0094.01
Plans and drawings: the text below has words only, no drawings.
ROOF LEGEND
BC Barge Capping
BG/VG Box Gutter/ Valley Gutter
CB-C1 Metal roof sheeting
CV Chamber Vent
DP Downpipe (100 or 150Ø)
EG Eaves Gutter
KE Kitchen Exhaust - refer
mech. doc.
BRIDGE ARBOUR LBB Line of Building Below
OH Overhang
PV Photovoltaic Panels
RC Ridge Capping
SCR-4 100x50 Aluminium Battens
SCR-5 100x100 Aluminium Battens
A B C D SU Sump
VP Vent Pipe
SCR-5 WB Whirly Bird - refer mech.
doc.
Exhaust Riser
NOTES
1. Provide insulation and roofing
underlay to full extent of roof
as per energy efficiency report.
2. Refer to specification for full
product details and warranties.
3. Scribe flashings and capping to
roof sheet profile.
SCR-4
ARBOUR
BC BC SCR-5
DP DP
DP EG DP
EG
3,000
LBB
OH
ARBOUR
1 SU 1
600
OH
DP EG DP
1,370
LBB
RC
600
OH
LBB LBB EG
2 2
600
OH EG 600
R
OH LBB
C
G VP
3,104
/B
DP
LBB
VG
SU
C
SU EG
R
EG
CV DP DP
LBB
3 DP CV 3
600
OH
EG
LBB
CB-C1
16.0° Pitch C DP
R CB-C1
CB-C1 16.0° Pitch
VG
16.0° Pitch
G
600
/B
/B
OH
G
R
VG
C
PV PV PV PV PV PV PV
SU
WB ID
EGDP
WB WB WB WB
#Element
RC KE
PV PV PV PV PV PV PV
21,379
RC CB-C1 DP
16.0° Pitch
RC
VG
15,105
/B
G
R
C
BC VP
VP
WB DP
C
R
LBB
VG
RC CB-C1
/B
PV PV PV PV PV PV PV WB RC
16.0° Pitch
R
G
C
WB G
/B
G
LBB
V
PV PV PV PV PV PV PV EG
CB-C1 LBB
16.0° Pitch
1,500
OH
VP
R
C
C
R
VP DP DP EG DP DP
4 LBB SU
4
LBB
SU
1,500
600
1,800
OH
OH EG EG 600
OH
5 DP 5
DP DP EG DP LBB
DP EG DP
A B C D
FOR INFORMATION ONLY
Contact Revision Project Stage Architect Project No.
(07) 3251 6900 01 For Coordination 11/08/2025 Noosa Early Learning Centre Building Application SC 1187-05 Roof Plan
02 Issue for Review 14/10/2025 Lot 4 Noosa
20 Prospect St, Fortitude Valley QLD 4006
A-WD-04.01 05
03 Issue for Coordination 22/10/2025
[email protected] Client Status Drawn Scale
04 Issue for Coordination 11/11/2025
Stockwell Development Group Pty Ltd Not For Construction TS 1:100 at A1
05 Issue for Coordination 4/02/2026
Elevation Architecture Pty Ltd ACN 606 170 807 © Copyright reserved this document is and shall remain the property of Elevation Architecture. Unauthorised use of this document in any form whatsoever is prohibited. All information to be printed in colour. Figured dimensions take precedence over scale dimensions. Contractors must verify all dimensions on site before commencing any work or making shop drawings. P:\Data 1\1187-05 Sanctuary Noosa Childcare Centre\5.3 Design Development\5.3.1 ArchiCAD\1187-05_Master DD 28.pln
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
A-WD-04.01-05-Roof Plan.pdfRelated documentApplication case desk ↗
About this file
- File size
- 353 KB (small file)
- File type
No other editions are linked here.