Original source · versioned page text
Attachment 5 - Bushfire Hazard Assessment & Management Plan
Plans and drawings: the text below has words only, no drawings.
Very large file (11.4 MB): may take a few minutes to open.
Original PDF page 17, section 1. The text section number identifies this passage in the reader.
Bushfire Hazard Assessment & Management Plan v1 NCES REF: J000542 Lot 9 on RP225312 – 100 Cooyar Street, Noosa Heads 3.6 Quantitative Modelling Quantitative modelling of the potential bushfire conditions that may be experienced within the VHC 22.1 open forest, VHC 29.2 woodland, and VHC 34.5 shrubland within the site and adjoining the site has been undertaken to assist in determining the suitability of the development and any asset setback requirements. The models used comprise industry standard bushfire equations which have been built into the FPAA endorsed FLAMESOL computer model. FLAMESOL allows numerous input variables to be adjusted including fuel loads, fire danger index, site slope and distance to vegetation. FLAMESOL uses the following algorithms: Rate of Spread – McArthur (1973) and Nobel et al. (1980) Flame Length – NSW Rural Fire Service (2001) and Nobel et al. (1980) Elevation of Receiver – Douglas and Tan (2005) Flame Angle – Douglas and Tan (2005) Radian Heat Flux – Drysdale (1999), Sullivan et al. (2003) and Douglas and Tan (2005) The FLAMESOL Minimum Distance calculator has been used and comprises an AS 3959:2018 Method 2 (Appendix B) based calculator which will determine standard bushfire behaviour variables as well as the minimum distances required to achieve a range of different radiant heat levels (represented by BAL's). Fuel load inputs have been drawn from Planning for Bushfire Resilient Communities (QFES 2019) based on the calculated potential fuel loads for the following; VHC 22.1 (23.4 t/ha surface and near surface fuels and 28.4 t/ha total fuels); VHC 29.2 (16.8 t/ha surface and near surface fuels and 24.3 t/ha total fuels); and VHC 34.5 (8 t/ha surface and near surface fuels and 13 t/ha total fuels). A 1º effective slope was adopted for the slope underlying all sub units given across slope conditions underlying the vegetation. The default Flame Width of 100m was chosen for all units. A Forest Fire Danger Index (FFDI) of 48 has been adopted for the site consistent with the assignment by QFES (Catalyst 2020) (refer Plate 11). Plate 11 – FFDI (Source: QFES redi Map) The Flamesol output results are shown in Plates 12-14. © 2021 16
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.