Noosaville Locality Code - Division 17
Attached to the e-mail Assessment against codes MCU16/0138 & OPW16/0257.
SPECIFIC OUTCOMES PROBABLE SOLUTIONS COMPLIANCE COMMENTS
drained; b) the infrastructure has the capacity to accept any additional loading;
d) ensure drainage does not adversely impact AND
upon other premises; and S17.3 For Residential Uses— Inconsistency Both proposed Duplex developments result
e) ensure filling or excavation does not a) where slab on ground construction is used, filling does not extend Between Codes in the filling of the entire sites. This is not
adversely impact upon other premises by— more than 1m beyond the building footprint and access to car parking compliant with Probable Solution S17.3 of
i. causing ponding on the site or nearby areas, measured from the outer walls of the building ; or the code.
land; b) the design consists of a suspended floor construction;
ii. increasing flooding, which adversely AND Despite the non-compliance with the code,
affects the safety or use of any land it is noted that Probable Solution S18.1 of
upstream and downstream; and the Natural Hazards Overlay Code
iii. adversely affecting the flow of water in specifies that the entire lot must be located
any overland flow path. above Q100 ARI.
Section 2.4 of the planning scheme
specifies that that an Overlay Code prevails
to the extent of the inconsistency.
Accordingly, the Probable Solution
prescribed in this code, is overridden by
requirements of the overlay code.
S17.4 Car parking and maneuvering areas are constructed at a level that Yes All elements of the development have been
permits the parking area to drain from the site by gravity means, without designed in accordance with a relevant
the need for mechanical pumping; Flood Information Certificate and drain to
AND Gympie Terrace.
S17.5 Basements for residential uses have flood immunity above the N/A Neither Duplex development proposes a
Q100 where alternative means to mechanical pumping are used to basement.
achieve such immunity; or
S17.6 Basements for non-residential uses have flood immunity above the N/A Neither Duplex development proposes a
Q100 that may be achieved by means of mechanical pumping where the basement.
mechanical feature is installed with adequate holding tanks and an
alternative back up power source.
Sloping sites
O18 Development on sloping sites— S18.1 Buildings and associated accessways are not constructed on land N/A The sites do not contain significant slopes.