Lee White Res. C 29.10.19 (002) · OPW21/0053
Attached to the e-mail Operational Works Application opw21/0053 - 5 Lunar Cres Noosa Heads.
Original PDF page 1, section 1. The text section number identifies this passage in the reader.
Tony Walton Designs BUILDER :
QBCC LICENCE No. - 1141195
m - 0403 871 366
e - [email protected]
p - 5 Diamond Close
Yaroomba QLD 4573 QBCC No. 1272680 MOB: 0418 510 590 [email protected]
NOTE: THESE PLANS SHOULD ONLY BE USED FOR CONSTRUCTION IF THEY HAVE BEEN PAGE DRAWING
STAMPED AND APPROVED BY EITHER LOCAL COUNCIL OR A PRIVATE CERTIFIER
00 TITLE COVER (THIS SHEET)
01 SITE PLAN - 1:200
02 GROUND FLOOR PLAN - 1:100
03 UPPER FLOOR PLAN - 1:100
04 ROOF PLAN - 1:100
05 ELEVATIONS 1 & 2 - 1:100
06 ELEVATIONS 3 & 4 - 1:100
07 CROSS SECTIONS A--A - 1:100
08 SLAB SET-OUT PLAN - 1:100
09 LOWER ELECTRICAL PLAN - 1:100
10 UPPER ELECTRICAL PLAN - 1:100
CLIENT : LEE WHITE
Proposed [email protected] Lunar Crescent
© COPYRIGHT - No reproduction of all or part of these drawings may be undertaken without the written consent of the author.
SITE : LOT 32 (No.5) LUNAR
This design remains the property of TAYLOR'D Distinction. Design NOT produced by TWD - Tony Walton Designs (Drafting ONLY). CRESCENT, NOOSA HEADS
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of sections 2 to 5 (of 12)
Section 2
RPD CONTOUR SURVEY AS SUPPLIED BY LIVINGSTON SURVEYS - PH (07) 5444 2922
NOTE: ALL WINDOWS AND DOORS OPENING INTO
POOL ENCLOSURE TO COMPLY WITH POOL SAFETY
LOT 32 ON RP 94023 REQUIREMENTS (ALL LOUVRES MAX. 102mm BLADES)
POOL AND FENCING TO SPECIALIST CONTRACTORS
PARISH OF WEYBA SPECIFICATIONS - PLANS SHOWN INDICATIVE ONLY.
23
41
COUNTY OF MARCH
940
23
ALL 190 CONCRETE BLOCK RETAINING WALLS
42
RP
AREA - 653m²
940
LOCATED 150mm (MIN) OFF SIDE & REAR BOUNDARIES
RP
155°00' 26.103
25
23
24
25
Link-Block Retaining Wall
300 x 300 GRATED STORMWATER
PITS INSTALLED TO MAN. SPEC. 24
POOL
mo nce
ed
lish
De eside
1.8m HIGH TIMBER PALING
To ber R hset
BOUNDARY FENCE (TYPICAL)
Tim Hig
Deck ALL 190 CONCRETE BLOCK RETAINING WALLS
FL 23.24 LOCATED 150mm (MIN) OFF SIDE & REAR BOUNDARIES
Be
23
31
940
Low Block Retaining Wall
RP
22
.300 23
Sh ber
ed
Tim
90
23
PROPOSED
0" 25
FL eck
33
22.
940
D
RESIDENCE
RP
46'3
g
RL py Pe
e
05
enc
Re torey
260°
21.
m
21
32
FL eck
Du
sid
23.
Bri wo S
D
Eave 24.44
e
enc
Re torey
65°00' 30.156
T
ck
22
sid
4
6.0
Bri wo S
2
ve
SITE COVER (N.S.C.) -
Ea
T
ck
945
FL eck
23.
SITE AREA - 653m2
D
GROUND FLOOR SITE COVER ALLOWABLE - 50% (326.5m² max)
Gar Iron
FL 2 age
0.32
GROUND FLOOR SITE COVER ACHIEVED - 45.160% (294.9m²) GARAGE
32
.
Galv
UPPER FLOOR SITE COVER ALLOWABLE - 30% (195.9m² max)
GROUND FLOOR SITE COVER ACHIEVED - 13.185% (86.1m²) 1.8m HIGH TIMBER PALING
21
32
BOUNDARY FENCE (TYPICAL)
FL eck
653 m²
23.
D
DENOTES PROPOSED RESIDENCE - ROOFED OUTDOOR
20
Eave 24.64
2
.92
DENOTES PROPOSED RESIDENCE - UPPER FLOOR 300 x 300 GRATED STORMWATER
"6
PROPOSED DRIVEWAY & CROSSOVER TO PITS INSTALLED TO MAN. SPEC.
'20
COMPLY WITH N.S.C. REQUIREMENTS EXPOSED AGG.
59
DRIVEWAY
7°
DENOTES PROPOSED RESIDENCE - GROUND FLOOR 20
27
334°59'20" 15.456
y
ewa
Driv
SITE PLAN SCALE: 1:200
19
d
Pave
Brick
PLANNING SCHEME SUMMARY
Pit s
tu
Op
PLANNING ZONES - DETACHED HOUSING
19
wa gg
ive d A
LAND SUBJECT TO ACID SULPHATE SOILS OVERLAY
y
REMOVE EXISTING CROSSOVER &
D r o se
REINSTATE KERB & CHANNEL TO
- LOW POTENTIAL ACID SULPHATE AREA 5-20m AHD
t
p
en
Ex
N.S.C. REQUIREMENTS
c
LAND SUBJECT TO BUSHFIRE HAZARD OVERLAY e s
Cr
- POTENTIAL IMPACT BUFFER
HEIGHT OF BUILDING AND STRUCTURES OVERLAY - 8.0 METRES
RL Conc ail
i n se t N
Ra TBM
18. .
01
LOCAL AUTHORITY -
r 18
18
m
a
NOOSA SHIRE COUNCIL un L
STORMWATER TO DISCHARGE INTO EXISTING
SYSTEM TO N.S.C. REQUIREMENTS
SEWERAGE TO N.S.C. DESIGN
REV. AMENDMENT DESCRIPTION DRAWN CHECKED DATE BUILDER NOTES CLIENT PROJECT Start Date: 09/07/19 JOB No:
A ISSUED FOR BUILDING APPROVAL APPLICATION. TW TW 17/09/19
1. ALL DIMENSIONS ARE TO BE VERIFIED PRIOR TO COMMENCMENT OF WORK.
2. GIVEN DIMENSIONS ARE TO HAVE PRIORITY TO SCALED DIMENSIONS. LEE WHITE PROPOSED RESIDENCE Issued Date: 29/10/19 025/19
B CLIENT AMENDMENTS. ISSUED FOR BUILDING APPROVAL APPLICATION. TW TW 30/09/19
3. ALL GROUND LEVELS ARE APPROXIMATE ONLY AND SHOULD BE VERIFIED. REV No:
C CLIENT AMENDMENTS. ISSUED FOR BUILDING APPROVAL APPLICATION. TW TW 29/10/19 4. ALL PLUMBING AND DRAINAGE IS TO COMPLY WITH STANDARD SITE ADDRESS Scale: 1:200 @ A2
SEWERAGE BY-LAWS AND REQUIREMENTS OF THE LOCAL AUTHORITY.
5. CONTRACTOR TO IMMEDIATELY NOTIFY DESIGNER OF ANY DISCREPENCIES.
DRAWING C
6. ALL WORKS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE LOT 32 (No.5) LUNAR SITE PLAN
Design by: TAYLOR'D Distinction
CRESCENT, NOOSA HEADS
QBCC No. 1272680 MOB: 0418 510 590 [email protected] CURRENT BUILDING CODE OF AUSTRALIA , AMENDEMENTS AND IN
E-mail: [email protected] Ph: 0403 871 366
QBCC LICENCE No. - 1141195
ACCORDANCE WITH RELEVANT TRADE AND TECHNICAL MANUALS.
Drawn by: TW 01
Section 3
1,290 6,220 9,740 690
90 2,100 90 3,850 90 4,725 290 4,725 600 90
LEGEND: 90 1,200 90 1,910 90 2,180 90 1,510 90 5,560 90 2,860 90 2,000 90
FG - FIXED GLASS WINDOW O/H - OVERHANG
L- LOUVRE WINDOW FFL - FINISHED FLOOR LEVEL 1,290 90 2,000 1,680 500 90 7,250 900 1,210 750 90 955 90 955 90
DH - DOUBLE HUNG WINDOW AHD - AUSTRALIAN HEIGHT DATUM A
REF - REFRIGERATOR 190 CONCRETE BLOCK RETAINING WALLS
AWN. - AWNING WINDOW TO STRUCTURAL ENGINEER'S DETAILS
SW - SLIDING WINDOW DW - DISH WASHER
406
EASTERN REAR BOUNDARY LINE
SD - SLIDING DOOR CT/UBO - COOK TOP/UNDERBENCH OVEN
SL - SIDE LIGHT OHC - OVERHEAD CUPBOARDS
CSD - CAVITY SLIDING DOOR SHR - SHOWER 0.9m HIGH BLOCK RETAINING WALL 1.3m HIGH BLOCK RETAINING WALL 1.7m HIGH BLOCK RETAINING WALL 2.0m HIGH BLOCK RETAINING WALL
(SM) - SITE MEASURED EXT. SHR - EXTERNAL SHOWER
2,705 7,500 2,315
400
400
0.7m HIGH BLOCK
M -
RETAINING WALL
(T) - TRANSLUCENT GLASS SHS MULLION GL 22.11 AHD SELECT 1200 HIGH SEMI-FRAMELESS GLASS REINFORCED CONCRETE POOL TO
3,006
(R) - RESTRICTED OPENING SD - SMOKE DETECTOR POOL FENCE INSTALLED TO MAN. SPEC. STRUCTURAL ENGINEER'S DETAILS
2,600
GL 22.11 AHD
SELECT ALUMINIUM FRAMED DOORS & POOL
POOL
2,500
2,500
WINDOWS INSTALLED TO MAN. SPEC.
TERRACE
3,830
(TURF)
(2.5m x 7.5m)
90 2,615 2,400 (DECKING)
2106 L (T)
NO GABLE O/H
DP
90
ALL LOUVRE WINDOWS TO BE FULLY AUTOMATED
1,230
600 O/H
1.0m WIDE FOOTPATH (EPOSED AGG.)
21075 L
930
930
WITH REMOTE, INSTALLED TO MANUFACTURER'S SPEC. DP 1.8m HIGH BLOCK FENCE
0.4m HIGH BLOCK
RETAINING WALL
SKYLIGHT
600 O/H
OVER
SUPPLY & INSTALL 102mm BLADES TO ALL LOUVRE POOL POOL FENCE POOL POOL FENCE
POOL
190
(2700 CEILING HT.) GATE GATE
ROBE
WINDOWS LOCATED ON THE UPPER FLOOR PLAN GATE
SPLIT SYSTEM
MASTER
4,700
5,030
BEDROOM
ROBE
190 x 290 CONC. BLOCK PIER & FOOTINGS
WIR
4,940
ALL EXTERNAL SLIDING DOORS & WINDOWS TO BE SUPPLIED (CARPET) (CARPET)
TO STRUCTURAL ENGINEER'S DETAILS
WITH FLY SCREENS TO MANUFACTURER'S SPECIFICATIONS (2800 CEILING HT.)
BBQ
ENCLOSURE
POOL PUMP
3,800
600 O/H
ALFRESCO
3,610
FFL 22.41 AHD FFL 22.31 AHD
AREA GL 22.11 AHD
04075 SW (T)
(EPOXY FINISH)
SUPPLY & INSTALL 6kw PHOTOVOLTAIC ARRAY PANELS ON
21075 L
100mm ALL CABINETRY SHOWN INDICATIVE ONLY
APPROPRIATE ROOFS TO MANUFACTURER'S SPEC. STEP DOWN (REFER TO CABINETMAKERS SPECIFICATIONS)
310 O/H
UNDER FLOOR HEATING (SEE NOTE)
1.0m WIDE FOOTPATH (EXPOSED AGG.)
500
SUPPLY & INSTALL SOLAR HOT WATER SYSTEM TO 2430 STACKER DOOR XXO 1024 L
90
90
DP 820 CSD SD
600 GABLE O/H
90
MANUFACTURER'S SPECIFICATIONS OHC
90
90
90
600
700
0612 SW (T)
PANTRY
1,200
2,180
WALK-IN
2,000
SUPPLY & INSTALL FULLY DUCTED AIR CONDITIONING
1,800
SHR
(2700 CEILING HT.) 920
TO SPECIALIST CONTRACTORS DESIGN & SPECIFICATIONS
2106 L
1,200
ENSUITE SCULLERY
820 CSD
1,190
2,910
(TILES) 1,600 2,400 (TIMBER)
90
SUPPLY & INSTALL UNDER FLOOR HEATING TO ENSUITE
1,150 90
0608 SW (T)
1000 HIGH
600
750 HIGH
SD
TO SPECIALIST CONTRACTORS DESIGN & SPECIFICATIONS
600
LINEN
1,150
BATH REF
5,270
TOP OF RETAINING WALL RL 21.95
90
(2700 CEILING HT.)
13,840
SUPPLY & INSTALL SELECT SINGLE SECURITY ENTRY GATE (2700 CEILING HT.)
KITCHEN
LIVING
(TIMBER)
WITH INTERCOM SYSTEM IN FRONT FENCE TO MAN. SPEC.
90
90
EXTENT OF FLOOR OVER
3,110
SPLIT SYSTEM (TIMBER) DRY
L'DRY
2,510
2,510
600 O/H
OHC
NICHE & HOB AT
EXTENT OF FLOOR OVER
END OF BATH (TILES) WM
0612 SW
8,290
FFL 22.41 AHD
2 x 720 CSD
3,200
(2700 CEILING HT.)
2115 L
REINFORCED CONCRETE SLAB & FOOTINGS
90
3,740
820 CSD
MEDIA TO STRUCTURAL ENGINEER'S DETAILS
21,150
90
(CARPET)
NORTHERN SIDE BOUNDARY LINE
90
920 with DP
920 CSD
1,190
FFL 22.41 AHD Retractable
820 (2700 CEILING HT.) fly-screen
1,700
UP
6,530
SD DINING
600
70
(TIMBER)
LINEN
600 GABLE O/H
3,590
90
PLANTER
820
90
90
1,930 STORE
BOX
UNDER (2700 CEILING HT.)
2108 L
0615 SW (T)
WALK-IN Section 4
BATH
1,800
1,800
STORE SHR (TILES)
LIBRARY UNDER
2,710
UP (CARPET) UP EXTENT OF FLOOR OVER UP
90
920
GALLERY FFL 20.61 AHD
1,570
1,180 90
90
DP
1,590
SPLIT SYSTEM 1800mm
1,180
DP (EPOXY FINISH) STEP DOWN
1200 600 O/H
DP
190
90
820
UP TIMBER STUD WALL FRAMES TO STRUCTURAL
90
2445 L ENGINEER'S TIMBER FRAMING SCHEDULE
600 GABLE O/H
600 GABLE O/H 2160mm
1,610
STEP DOWN
1,800
PORTICO 100mm
1,800
FFL 20.51 AHD (EXPOSED AGG.)
E
STEP DOWN
RY LIN
(EPOXY FINISH)
UNDA
600 190
DP
(2700 CEILING HT.)
BO
DOUBLE 600 O/H
NO O/H
UP UP
6,590
SIDE
190 x 290 CONC. BLOCK PIER & FOOTINGS
6,210
5,960
6,210
6,080
GARAGE TO STRUCTURAL ENGINEER'S DETAILS
HERN
(EPOXY FINISH)
REINFORCED CONCRETE SLAB & FOOTINGS
FFL 20.25 AHD TO STRUCTURAL ENGINEER'S DETAILS
SOUT
4,280
4,280
1.2m WIDE FOOTPATH (EXPOSED AGG.)
600 O/H
GL 19.97 AHD
DP
NO GABLE O/H
190
190
190
2448 PANELIFT DOOR
0 1 2 3 4 5
A
GROUND FLOOR PLAN 90 5,180 90 ENTRY GATE
WITH INTERCOM
7,160 90 1,860 90 910 90 1,000 90
Living: 175.6m²
90 2,890 1,000 90 1,200 90 1,200 90 1,200 4,670 90 3,950 90
Alfresco: 40.0m²
Garage: 45.3m² 4
Gallery: 19.6m² 1,530 90 3,890 90 1,200 90 7,160 90
Portico: 12.9m² 1 3
190 6,610 190 6,860 290
Ground Floor: 293.4m² 2
Upper Floor: 86.1m²
BIN RECESS
6,990 7,150 4,040 1,000
Total: 379.5m²
19,180
REV. AMENDMENT DESCRIPTION DRAWN CHECKED DATE BUILDER NOTES CLIENT PROJECT Start Date: 09/07/19 JOB No:
A ISSUED FOR BUILDING APPROVAL APPLICATION. TW TW 17/09/19
1. ALL DIMENSIONS ARE TO BE VERIFIED PRIOR TO COMMENCMENT OF WORK.
2. GIVEN DIMENSIONS ARE TO HAVE PRIORITY TO SCALED DIMENSIONS. LEE WHITE PROPOSED RESIDENCE Issued Date: 29/10/19 025/19
B CLIENT AMENDMENTS. ISSUED FOR BUILDING APPROVAL APPLICATION. TW TW 30/09/19
3. ALL GROUND LEVELS ARE APPROXIMATE ONLY AND SHOULD BE VERIFIED. REV No:
C CLIENT AMENDMENTS. ISSUED FOR BUILDING APPROVAL APPLICATION. TW TW 29/10/19 4. ALL PLUMBING AND DRAINAGE IS TO COMPLY WITH STANDARD SITE ADDRESS Scale: 1:100 @ A2
SEWERAGE BY-LAWS AND REQUIREMENTS OF THE LOCAL AUTHORITY.
5. CONTRACTOR TO IMMEDIATELY NOTIFY DESIGNER OF ANY DISCREPENCIES.
DRAWING C
6. ALL WORKS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE LOT 32 (No.5) LUNAR GROUND FLOOR PLAN
Design by: TAYLOR'D Distinction
CRESCENT, NOOSA HEADS
QBCC No. 1272680 MOB: 0418 510 590 [email protected] CURRENT BUILDING CODE OF AUSTRALIA , AMENDEMENTS AND IN
E-mail: [email protected] Ph: 0403 871 366
QBCC LICENCE No. - 1141195
ACCORDANCE WITH RELEVANT TRADE AND TECHNICAL MANUALS.
Drawn by: TW 02
Section 5
11,580 560
4,360 7,220
LEGEND: 90 3,970 70 3,000 90
FG - FIXED GLASS WINDOW O/H - OVERHANG
L- LOUVRE WINDOW FFL - FINISHED FLOOR LEVEL 90 2,670 70 1,230 70 1,600 70 1,330 90
DH - DOUBLE HUNG WINDOW AHD - AUSTRALIAN HEIGHT DATUM A
AWN. - AWNING WINDOW REF - REFRIGERATOR
SW - SLIDING WINDOW DW - DISH WASHER EASTERN REAR BOUNDARY LINE
SD - SLIDING DOOR CT/UBO - COOK TOP/UNDERBENCH OVEN
SL - SIDE LIGHT OHC - OVERHEAD CUPBOARDS 90 11,400 560 90
CSD - CAVITY SLIDING DOOR SHR - SHOWER
(SM) - SITE MEASURED EXT. SHR - EXTERNAL SHOWER
(T) - TRANSLUCENT GLASS M - SHS MULLION
3,006
(R) - RESTRICTED OPENING SD - SMOKE DETECTOR
SELECT COLORBOND CUSTOM ORB
ROOF SHEETING FIXED TO MAN. SPEC. SELECT COLORBOND FASCIA & GUTTER
(TYPICAL) INSTALLED TO MAN. SPEC.
DP
FASCIA & GUTTER DP
ALL LOUVRE WINDOWS TO BE FULLY AUTOMATED
WITH REMOTE, INSTALLED TO MANUFACTURER'S SPEC.
4,307
FASCIA & GUTTER
SUPPLY & INSTALL 102mm BLADES TO ALL LOUVRE
SELECT 600 x 600 SKYLIGHT
WINDOWS LOCATED ON THE UPPER FLOOR PLAN INSTALLED TO MAN. SPEC.
ROOF TRUSSES & BRACING TO
TRUSS MANUFACTURER'S DETAILS
12.5° ROOF
ALL EXTERNAL SLIDING DOORS & WINDOWS TO BE SUPPLIED 12.5° ROOF PITCH
WITH FLY SCREENS TO MANUFACTURER'S SPECIFICATIONS PITCH
ROOF TRUSSES & BRACING TO
SELECT COLORBOND CAPPINGS &
TRUSS MANUFACTURER'S DETAILS
SUPPLY & INSTALL 6kw PHOTOVOLTAIC ARRAY PANELS ON FLASHINGS INSTALLED TO MAN. SPEC.
APPROPRIATE ROOFS TO MANUFACTURER'S SPEC.
600 O/H
DP with
SUPPLY & INSTALL SOLAR HOT WATER SYSTEM TO DP
600 x 2250 SW XOX (R) 0615 SW (T) Spreader
MANUFACTURER'S SPECIFICATIONS
90
90
90
TIMBER STUD WALL FRAMES TO STRUCTURAL NICHE & HOB AT
1800 BATH
ENGINEER'S TIMBER FRAMING SCHEDULE END OF BATH
SUPPLY & INSTALL FULLY DUCTED AIR CONDITIONING 1,750 WALK-IN
600 GABLE O/H
600 GABLE O/H
SHR
TO SPECIALIST CONTRACTORS DESIGN & SPECIFICATIONS (2700 CEILING HT.) (2700 CEILING HT.)
BED 4 BATH
2,800
2,800
3,490
3,490
3,400
TIMBER FLOOR FRAMING TO (CARPET) (TILES)
06075 L (T)
STRUCTURAL ENGINEER'S SPEC. SD
600 O/H RIDGE CAPPING 2,423
600
70
ROBE LINEN
920 CSD 820 CSD
90
90
90
90
90
620
1,100 90
08075 L
08075 L
SD
1,280
HALL
FASCIA & GUTTER
(RAKED CEILING)
12.5° ROOF (TIMBER)
PITCH (RAKED CEILING)
9,720
SITTING
2,640
2,710
70
70
70
920 920
90
(TIMBER)
SD SD
NORTHERN SIDE BOUNDARY LINE
ROBE
600 x 2250 SW XOX (R)
2,130
1,515
600 GABLE O/H
600 GABLE O/H
DN DP
(RAKED CEILING) (RAKED CEILING)
BED 3 BED 2
3,610
6,230
70
3,540
3,540
6,050
(CARPET) (CARPET)
06075 L
1,340 70
2,000
ROBE
2,000
1,340 90
90
90
90
DP with 1424 L 1424 L DP with
1,340
Spreader Spreader
1,340
600 O/H
600 GABLE O/H
DP 1,502
FASCIA & GUTTER DP
DP
90
90
DP with 1215 FG
Spreader
12.5° ROOF SELECT ALUMINIUM FRAMED DOORS &
600 O/H PITCH WINDOWS INSTALLED TO MAN. SPEC.
E
PARAPET
RY LIN
SELECT COLORBOND FASCIA & GUTTER
(TYPICAL) INSTALLED TO MAN. SPEC.
UNDA
FASCIA & GUTTER
BO
SIDE
FASCIA & GUTTER DP
4,579
12.5° ROOF
HERN
PITCH TIMBER ROOF FRAMING & BRACING
TO STRUCTURAL ENGINEER'S SPEC.
SOUT
ROOF TRUSSES & BRACING TO
TRUSS MANUFACTURER'S DETAILS
820
DP
0 1 2 3 4 5
A
UPPER FLOOR PLAN 90 3,090 70 3,650 70 600 3,920 90
Living: 86.1m²
4 90 2,490 70 600 3,650 70 4,520 90
Upper Floor: 86.1m²
6,000
1 3 90 2,490 90
2 2,670 8,910
11,580 560
REV. AMENDMENT DESCRIPTION DRAWN CHECKED DATE BUILDER NOTES CLIENT PROJECT Start Date: 09/07/19 JOB No:
A ISSUED FOR BUILDING APPROVAL APPLICATION. TW TW 17/09/19
1. ALL DIMENSIONS ARE TO BE VERIFIED PRIOR TO COMMENCMENT OF WORK.
2. GIVEN DIMENSIONS ARE TO HAVE PRIORITY TO SCALED DIMENSIONS. LEE WHITE PROPOSED RESIDENCE Issued Date: 29/10/19 025/19
B CLIENT AMENDMENTS. ISSUED FOR BUILDING APPROVAL APPLICATION. TW TW 30/09/19
3. ALL GROUND LEVELS ARE APPROXIMATE ONLY AND SHOULD BE VERIFIED. REV No:
C CLIENT AMENDMENTS. ISSUED FOR BUILDING APPROVAL APPLICATION. TW TW 29/10/19 4. ALL PLUMBING AND DRAINAGE IS TO COMPLY WITH STANDARD SITE ADDRESS Scale: 1:100 @ A2
SEWERAGE BY-LAWS AND REQUIREMENTS OF THE LOCAL AUTHORITY.
5. CONTRACTOR TO IMMEDIATELY NOTIFY DESIGNER OF ANY DISCREPENCIES.
DRAWING C
6. ALL WORKS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE LOT 32 (No.5) LUNAR UPPER FLOOR PLAN
Design by: TAYLOR'D Distinction
CRESCENT, NOOSA HEADS
QBCC No. 1272680 MOB: 0418 510 590 [email protected] CURRENT BUILDING CODE OF AUSTRALIA , AMENDEMENTS AND IN
E-mail: [email protected] Ph: 0403 871 366
QBCC LICENCE No. - 1141195
ACCORDANCE WITH RELEVANT TRADE AND TECHNICAL MANUALS.
Drawn by: TW 03
The text continues on section 6.