Smoke alarms to:
- Smoke alarms to all bedrooms;
- Smoke alarms to all hallways servicing bedrooms;
- Smoke alarms installed between areas containing bedrooms
- Smoke alarms installed on any other storey;
- Smoke alarms to be installed in locations that align with AS1670.6;
- Only photoelectric smoke alarms are to permitted to be used; and
- Smoke alarms must comply with AS3786-2014.
Smoke alarms must be installed:
- if practicable, on the ceiling—if the ceiling slopes, it must be in an area of the ceiling
that is between 500 millimetres and 1500 millimetres from the apex of the ceiling
- if installing on the ceiling is not practicable, on an exposed joist or beam that when
measured from the ceiling does not have a depth of more than 300 millimetres when
measured from the ceiling
- if these two placements are not practicable, the device can be installed on a wall in an
area that is between 100 millimetres and 300 millimetres from the ceiling and more than
300mm from the corner of 2 walls.
Smoke alarms must not be:
- within 300 millimetres of a light fitting;
- if installed on a ceiling, within 300 millimetres of a corner of the ceiling and a wall;
- if installed in a stairwell, out of reach of smoke because of an obstruction;
- within 400 millimetres of an opening from which air is supplied from an air conditioner
or force air ventilation within 400 millimetres of the blades of a ceiling fan.
SD
Timeframes:
(The laws will be phased in over a 10 year period and there are a number of triggers for
compliance including): Ceiling light
- Any smoke alarm being replaced after 1 January 2017 because it no longer operates or
has reached the end of its 10 year lifespan must be replaced with a photoelectric alarm.
- Dwellings approved to be built or significantly renovated after 1 January 2017 will need Down light
to comply with the new smoke alarm laws.
- Dwellings leased or sold after five years (i.e. from 1 January 2022) will need to comply SD Spotlight
with the new smoke alarm laws when the rental agreement is entered into or the property
is transferred.
- All private dwellings will need to comply with the new smoke alarm laws within 10 years Wall light
(i.e. by 1 January 2027).
Light switch
Single power point @ 450 height
Double power point @ 450 height
Double power point @ 1100 height
SD
Double power point and height
Telephone point
Television point
1200 ceiling fan
Fluorescent light
CT Cook top
UB Under bench oven
hws Hot water system
Meter box
2W Two way switching
Dim Dimming switch
Exhaust fan-light
GROUND FLOOR External tap
ELECTRICAL SETOUT PLAN
QDC MANDATORY PART 4.1 - SUSTAINABLE BUILDINGS
LIGHT FITTINGS MUST BE ENERGY EFFICIENT TO A MINIMUM OF 80 PER CENT
OF THE TOTAL FIXED INTERNAL LIGHTING. UNDER THE QDC, ENERGY EFFICIENT
LIGHTS MUST HAVE A MINIMUM EFFICACY OF 27 LUMNES PER WATT. DEPENDING
ON THEIR EFFICACY, COMPLIANT LAMPS MAY INCLUDE FLUORESCENT TUBES,
CFL's, NEON, METAL HALIDE AND LED.
REV. AMENDMENT DESCRIPTION DRAWN CHECKED DATE BUILDER NOTES CLIENT PROJECT Start Date: 09/07/19 JOB No:
A ISSUED FOR BUILDING APPROVAL APPLICATION. TW TW 17/09/19
1. ALL DIMENSIONS ARE TO BE VERIFIED PRIOR TO COMMENCMENT OF WORK.
2. GIVEN DIMENSIONS ARE TO HAVE PRIORITY TO SCALED DIMENSIONS. LEE WHITE PROPOSED RESIDENCE Issued Date: 29/10/19 025/19
B CLIENT AMENDMENTS. ISSUED FOR BUILDING APPROVAL APPLICATION. TW TW 30/09/19
3. ALL GROUND LEVELS ARE APPROXIMATE ONLY AND SHOULD BE VERIFIED. REV No:
C CLIENT AMENDMENTS. ISSUED FOR BUILDING APPROVAL APPLICATION. TW TW 29/10/19 4. ALL PLUMBING AND DRAINAGE IS TO COMPLY WITH STANDARD SITE ADDRESS Scale: 1:100 @ A2
SEWERAGE BY-LAWS AND REQUIREMENTS OF THE LOCAL AUTHORITY.
5. CONTRACTOR TO IMMEDIATELY NOTIFY DESIGNER OF ANY DISCREPENCIES.
DRAWING C
6. ALL WORKS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE LOT 32 (No.5) LUNAR LOWER ELECTRICAL
Design by: TAYLOR'D Distinction
CRESCENT, NOOSA HEADS
QBCC No. 1272680 MOB: 0418 510 590 [email protected] CURRENT BUILDING CODE OF AUSTRALIA , AMENDEMENTS AND IN
E-mail: [email protected] Ph: 0403 871 366
QBCC LICENCE No. - 1141195
ACCORDANCE WITH RELEVANT TRADE AND TECHNICAL MANUALS.
Drawn by: TW 09
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Lee White Res. C 29.10.19 (002).pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.3 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.