The site experiences no overland flow from other catchments. The catchment draining towards Ventura Street
is 0.074ha in area and is channelled towards the kerb and channel. Roofwater and hardstand areas from both
lot 1 and 2 are connected to an existing field inlet in the property frontage. This pit is the connected directly
to the kerb via kerb adaptors. The pre-development catchment is shown in Figure 2 (and Bax Engineering plan
075-028-SK01 as part of Appendix A).
Figure 2 – Pre-Development Catchment Plan
As part of the proposed renovations, the existing dwelling will increase in impervious area, however the
catchment will not increase. This increase in impervious area will continue to the same outlet point via a
detention tank located in the common property (lot 0 BUP13368). The post-development catchment is
shown in Figure 3 (and Bax Engineering plan 075-028-SK02 as part of Appendix A).