6.5.22 - Flooding Report 5 may
The original of this document is very large (21.8 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Original PDF page 10, section 1. The text section number identifies this passage in the reader.
25. Provide additional detail to demonstrate that the development (access and all lots)
achieves compliance with The Flood Hazard Overlay Code – Performance Outcome PO4.
Response: The Planning Scheme requires a minimum floor level of dwellings to be 0.3m
above the 1% (2100) AEP event. An assessment of the PMF event found that flood levels in
the PMF event are approximately 0.4m to 1.0m higher that the 1% (2100) AEP flood levels.
The recommended minimum building envelope / finished floor level (FFL) for each lot has
been taken as the greater of the DFE + freeboard (0.3m) or the PMF, as summarised in Table
4-5, so as to provide a refuge for residents in this event.
21-0288-FS001-V5 | Flood Investigation | 60 Glenridge Drive, Cooroibah |5
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.