Sunshine Butterflies PLANNING REPORT v.1.4
Attached to the e-mail Development Application - Sunshine Butterflies - 1 of 2 MCU16/0090.
4.1.2 Surrounding Locality
The surrounding lots are also zoned Rural Settlement and contain dwelling houses. An access
easement for a rear lot is located on the adjoining lot to the west. The rear lot also
accommodates existing stormwater overflow drainage from the subject lot along an eastern
strip. The Tewantin Forest Reserve is located on the southern side of McKinnon Drive and is
zoned Open Space Conservation.
5.0 STATUATORY PROVISIONS AND COMPLIANCE
5.1 STATE INTERESTS
5.1.1 State Planning Policy
The applicability of the relevant sections of the Queensland State Planning Policy are
considered below:
Relevant Policy Principle Comment
Natural Hazards Applicable: Part of the site is mapped as bushfire
hazard area and Acid Sulfate Soil Area on Council
overlay mapping.
This report provides details as to how the proposal
meets the criteria of the SPP in relation to these natural
hazards. Potential Acid Sulfate soils will not be
disturbed above the threshold volume for excavation or
fill.
5.1.2 SE Queensland Regional Plan
The site is included in the Rural Living Area in the Regional Plan. As a community activity in
the Rural Living Area, this application does not require assessment by the referral agency
under the State planning regulatory provisions.
5.1.3 Referral Agencies
The application requires referral to State Agencies. The relevant following referral triggers are
detailed under the Sustainable Planning Regulation:
Issue/ Trigger Comment
Department
State Controlled YES -Referral required to SARA as
Road - Part of the subject Concurrence Agency.
Department of land is within 25m of - Refer Attachment C for proposed
Main Roads a State Controlled works.
Road (178m frontage
to McKinnon Drive).
ERA NO - No Referral required to DEH as the
Environment - Operating sewerage total site development of 9EP (equivalent
Protection treatment works, persons) is much less than the 21EP trigger.
Regulation with a total daily peak - The site is located outside a
design capacity of sewerage service area and will provide for a
21EP to 100EP; if maximum of 60 persons/day.
treated effluent is
10
See the original
The page text is free to read. Viewing or downloading an original file needs an account.