Status Guidance level Recommended action
Red level action mode Level 1 guideline: Local authority and health
authorities to warn the public that
10 g/L total microcystins the water body is considered to be
or unsuitable for primary contact
recreation.
50 000 cells/mL toxic Microcystis
aeruginosa or biovolume equivalent of 4
mm3/L for the combined total of all
cyanobacteria where a known toxin
producer is dominant in the total biovolume.
b
or
Level 2 guideline:
10 mm3/L for total biovolume of all
cyanobacteria material where known toxins
are not present.
or
cyanobacterial scums are consistently
presentc.
Notes:
aThe definition of ‘dominant’ is where the known toxin producer comprises 75% or more of the total cyanobacteria in a representative sample.
bThis applies where high cell densities or scums of ‘nontoxic’ cyanobacteria are present, i.e. where the cyanobacterial population has been
tested and shown not to contain known toxins (microcystin, nodularin, cylindrospermopsin or saxitoxins).
cThis refers to the situation where scums occur at the recreation site each day when conditions are calm, particularly in the morning. Note that it
is not likely that scums are always present and visible when there is a high population, as the cells may mix down with wind and turbulence and
then reform later when conditions become stable.
Source: NH&MRC (2008) Guidelines for Managing Risks in Recreational Water. National Health and Medical Research Council, Australian
Government.
7.3 Guidelines for drinking water supply storages (South East Queensland
Water Corporation)
These guidelines are based on the water quality objectives developed by SEQ Water Corporation for drinking water
supply storages. They apply specifically to storages in south-east Queensland but would be appropriate for drinking
water supply storages throughout Queensland. Note that these guidelines are expressed slightly differently to
normal guidelines. For example, a Cryptosporidium guideline of >0 implies that action must be taken if values >0
are detected. The approach used and the significance of ‘Level 1’ and ‘Level 2’ are explained in more detail in the
table footnotes.
f
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.