Attachment D - Effluent disposal report

of 11

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

                    Covered Surface Drip Irrigation System
                             Utilize existing vegetation
150mm cover of mulch                                  1000mm max. Spacing


Ground Level




                                  Netafim or Wasteflow Pressure Compensating Dripper Lines
                                             Place on surface and cover with 150mm mulch.

150mm high mound surround




                       Diversion drain
                                         or Cut off drain              Irrigation lines




                       Slope greater than 15%

                                  Typical Plan Layout of Manifold and Laterals for an
Netafim or                                   Irrigation Area of 150m2
Wasteflow Pressure
Compensating Dripper
Lines
                                                            1m
To Advanced Secondary
ASTP

                          10m




          Flush-out Valves


                                                                 15m