   APPROVED PLAN
MCU22/0027 & OPW22/0054
   NOOSA COUNCIL
      19 MAY 2022


[OCR of page images]
 

PROPERTY
BOUNDARY

 

10 GAP

 

LEAVE 10mm GAP
(TO PREVENT NO LOAD
APPLIED TO WALL)

*RL 1.2m

 

12000

HAND RAIL LHS ONLY
REFER DETAILS

150 x 50 x 3 RHS JOISTS @ 500 CRS

FIXED TO BEARERS WITH 2 x M8 S.S BOLTS

TO EACH 150 x 50 x 6 ANGLE BRACKET
r- 347

QUAY LINE

DOUBLE FASCIA BOARDS

(REFER DETAILS)
JETTY #R.L_1.2m

 

 

 

RETAINING 4
WALL

 

 

 

 

**NOTE
JETTY R.L TO BE ADVISED

 

 

 

 

 

 

DECK CONSTRUCTION NOTES:

SAND AREA

 

 

 

 

 

ee
APPROX CANAL

 

 

 

PROFILE

 

 

 

ELEVATION
SCALE 1:50

 

|
|
|
|
|
|
NOT SHOWN FOR CLARITY
|
|
J
|

 

 

 
 

9315 46kNm ec |

INSITU PILES

 

 

 

 

 

 

APPROX 520

Ye HAT: R:L: 0.68m
178 x 76 x 6.35

AL. CHANNEL BEARERS FIXED

TO PILES WITH 2 x M16 SS BOLTS

CAST INTO PILE TOP OR CHEMSET

sess -MHWS R.L 0.36m
AHD R.L 0.0m

— LEVEL DATUM
“MLWS R.L 025m

oReis > © +» Rauaisaceie © ayite oj + + + > > pres apres + + - LAT R.L 0.42m

 

3000 MIN EMBEDMENT

INTO DENSE SAND OR

3500 MIN EMBEDMENT
INTO STIFF CLAY

 

APPROVED PLAN
MCU22/0027 & OPW22/0054

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* — Aluminium bearer & joist extrusions to be grade 6351-15
* Bearers to be 178 x 76 x 6.35 Aluminium channel NOOSA COUNCIL
* — Decking to be 135 x 32 HWD
* — Decking fixed to joists with 2 x 12 gauge SS screws at each joist 19 MAY 2022
* — Joists ot 500 crs from 150 x 50 x 3 Aluminium RHS with 3mm welded end Plates
* — Joists are fixed to Bearers with 150 x 50 x 6 Angle supports welded or M8 SS bolts
* — Fix bearers to top of insitu Piles with 2 x M16 SS—316 bolts cast or chemset 200mm into concrete
: TITLE:
D Crichton EDGE Consulting Hogineers| = THE MARINA SPECIALIST SURVEY DATA | JEN" RJ & ML DELANEY * ELEVATION
_ - | Woollpgebbe ap 4102 TRADING AS ACN 010633119 18 RON PARKINSON CRES | paTUM = LOT 110 (43) WITTA CIRCLE
Ph: +61 7 3367 3570 HE CORA et PT ain | HORI T=} NOOSA HEADS re TNS [SCN a
[email protected] Q GRID __| | \A3
HON 06 ow BT 98 SE PROVECT: 05/11/2021 | MM |1:50 1:20 1:5 |2 |
PHONE(O7) 5492 5925]HEGHT aun peRRiven|U2 TWALK - -
“B| REVSED_JETTY PROFILE SHAPE PER CLIENT | TOB [19/1721] SB|MECKE: PEG DATE: = SPECIALIST ORIGIN < PROPOSED PONTOON & CATW. DRAW — APPRD: JORG Not REV:
JOB | | SB_| ff 4 SURVEY
REV: DESCRIPTION BY | DATE [APPD GW 5496 10/01/2022 BOOKS TDB . JSP—SJ-35551 B

 

 

THIS DRAWING IS SUBJECT TO COPYRIGHT AND CANNOT BE REPRODUCED IN PART OR FULL OR PASSED ON TO A THIRD PARTY WITHOUT THE WRITTEN PERMISSION OF THE JETTY SPECIALIST

 

 
Log in to download the original file

Approved Plan - MCU22 0027 & OPW22 0054.pdf · 3.7 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.