Part 17 of 37 Appendix 15 - Groundwater Assessment MCU12/0208

of 103

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

Very large file (60.3 MB): the whole original can take several minutes to open, especially on a phone. Text is quick to read.

www.ac    ss.gs                                                                              +GILEEHI
                                                                                           SUT1-ERJ.AN)



                                                           4.2.2    Electrical conductivity
4          Results
                                                           Throughout the monitoring period, the results for
                                                           electrical conductivity (EC)ranged from

4.1      Groundwater level                                 0.06IlS/cm at BH58 on 27 March 2012 to
                                                           0.64IlS/cm at both GW2 and GW5 on 13 April
Throughout the monitoring period, groundwater              2012. Mean results were indicative of a freshwater
level has varied moderately across the bore                environment, and were below 0.62IlS/cm across
network. The largest range in level was recorded           the bore network.
at BH58 (1.73m to 2.93m from the top of the

monument).                                                 The largest range in EC was recorded at GW2

                                                           (0.56IlS/cm to 0.64IlS/cm) and BH58 (0.06IlS/cm
Generally, the highest levels have been recorded           to 0.12IlS/cm).

following periods of heavy rain. For example, 5
out of 6 monitored bores were at their highest             4.2.3    Dissolved metals
level during sampling in late March, following a           The concentrations of dissolved metals were
month of constant rain and three discreet events           generally consistent across the bore network, with
of over 80mm. The majority of remaining bores              limited variation between bores.
were at their     highest level during sampling in early
June, following a rain event of 85mm.                      The largest range in dissolved metal
                                                           concentration was recorded for iron, which ranged
4.2      Groundwater quality                               from <0.05mg/L at BH28 to 5.19mg/L at GW2.
                                                           The average concentration was 1 .3563mg/L
The analytical and insitu results for samples
                                                           across the bore network.
recovered from the Lake Weyba development site
are discussed in this section. Attached are
                                                           The concentration of dissolved aluminium ranged
complete results tables for each parameter                 from <0.01 mg/L at BH45 to1.0mg/L at GW1. The
(Appendix 3) and copies of the laboratory                  average concentration was 0.16mg/L across the
certificates and in situ sheets (Appendix 4).              bore network.

The location of the monitoring bores is shown in           The concentration of dissolved cadmium ranged
Drawing NO.1 0838.3.2.                                     from <0.0001 mg/L at the majority of locations to
                                                           0.001 mg/L at GW5. The average concentration
4.2.1  pH                                                  was   0.0002mg/L across the bore network.
Throughout the monitoring period, the results for
pH ranged from 2.8 at BH23 on 14 April 2012 to             The concentration of dissolved chromium ranged
14.58 at GW4 on 7 June 2012. Mean results                  from <0.001 mg/L at the majority of locations to
across the bore networkranged from 5.09 at                 0.002mg/L at BH4. The average concentration
BH23 to 9.14 at GW4. The largest range in pH               was 0.0011 mg/L across the bore network.

was recorded at GW5 (4.82 to 13.38) and GW4

(6.37to 14.58).                                            The concentration of dissolved copper ranged
                                                           from <0.001 mg/L at numerous of locations to
pH results were generally higher in the final round        0.018mg/L at GW5. The average concentration
of monitoring with an average of 9.62 calculated           was 0.0035mg/L across the bore network.

across the bore network,      compared with averages
of 4.25 and 5.11 in the rounds immediately                 The concentration of dissolved nickel ranged from
                                                           0.001 mg/L at BH28 and BH48 to 0.048mg/L at
preceding. Given the pH trend over the first five
rounds and the illogical results recorded during           BH4. The average concentration was 0.0011 mg/L

the final round of monitoring, equipment failure           across the bore network.

was suspected and the final round pH results
                                                           The concentration of dissolved lead ranged from
were excluded from the data set on the basis of
                                                           <0.001 mg/L at numerous of locations to
error.




1 0838_GWA_ELH2F.DOCX I NOOSA ON WEYBA I NORTHBROOK CORPORATION PIL          _
                                                                                 GROUNDWATER ASSESSMENT        21

Used in these records

About this file

File size
60.3 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Part 17 of 37 Appendix 15 - Groundwater Assessment MCU12_0208.pdf · 60.3 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.