FF_CEILING
260
2740
LASER CUT SCREENS
RENDERED EPS FOAM
7127
FIRST FLOOR CLADDING TO WINDOW HOOD
325
6105
2860
3040
BATTENS FIXED TO EASYLINE
CLADDING AND FLUSH FIT
SECTIONAL DOOR
BATTENS TO EXTEND 1000MM FROM
GROUND FLOOR WALL TO CREATE SCREENING
180
GARAGE
ELEVATION A
Scale 1 : 100
COLORBOND TRIMDEK
405MM STRIA CLADDING
ROOF SHEETING,
(OR SIMILAR) FIXED TO
FASCIA, AND GUTTER
8M HEIGHT LINE STUDWORK 2.00°
RAISED ROOF
UPSTAND
650
300
2740
400MM AXON CLADDING
(OR SIMILAR) FIXED TO
STUDWORK
FIRST FLOOR
325
2860
GROUND FLOOR
GARAGE
ELEVATION B
GENERAL NOTES
Scale 1 : 100
• ALL FIRST FLOOR WINDOWS TO BE RESTRICTED TO A
MAXIMUM 125MM OPENING
• DOORS TO WC, POWDER ROOM WC, & ENSUITE WC TO BE
FITTED WITH LIFT OFF HINGES IN ACCORDANCE WITH HOUSE TYPE B
B.C.A. 3.8.3
• WINDOW HEAD HEIGHT DIMESIONS TO BE TAKEN TO THE REVISION AMENDMENTS DATE BY Project ELEVATIONS A & B
NEAREST BRICK COURSE (UNLESS NOTED OTHERWISE) A DESIGN SKETCH 05-02-21 DW Shop 7, 2012 Logan Road DA
• ALL GLAZING TO COMPLY WITH A.S. 1288-2006 (Amdt
1-2008) (REFER TO ENERGY RATING FOR ALL GLAZING
Upper Mount Gravatt QLD 4122
Telephone: (07) 3219 3988
- Drafting By Date Scale
VALUES.) Email: [email protected] PO Box 455 Coorparoo QLD 4151
QBCC No. 81713 BDAA:5096-20 Mobile: 0413 127 282
21 NANNYGAI STREET CDS 05/02/21 1 : 100
• FOAM SYSTEM REFER TO ATTACHED SPECIFICATIONS Copyright to CDS Design Consultants E: [email protected] www.oneproperty.com.au NOOSAVILLE Project No. Issue Sheet No.
(WHERE APPLICABLE)
NANNYGAI A 3B of 3
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
DA Plans - Rev A 050221.pdfRelated documentApplication case desk ↗
About this file
- File size
- 4.6 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.