DRAINAGE NOTES:
12. CONTRACTOR TO ENSURE ALL MANHOLE STRUCTURES COMPLY
MCU23/0007 & RAL23/0001 1. REFER HYDRAULIC DRAWINGS FOR BUILDING DRAINAGE WITH THE MAXIMUM DEPTH SPECIFIED IN THE PROJECT
15 OCTOBER 2026 DETAILS. SPECIFICATION OR LOCAL AUTHORITY FROM FINISHED
SURFACE LEVEL TO UNDERSIDE OF ROOF SLAB. ANY NON
2. ALL ROADWORKS AND DRAINAGE (EXTERNAL TO SITE CONFORMANCE IS TO BE RECTIFIED AT THE CONTRACTORS
BOUNDARIES AND/OR COUNCIL OWNED DRAINAGE PIPES EXPENSE.
INTERNAL TO THE SITE BOUNDARIES) CONSTRUCTION AND
113.6
116.2
TESTING TO BE IN ACCORDANCE WITH NOOSA SHIRE COUNCIL 13. ALL FOOTPATHS TO BE CONSTRUCTED IN ACCORDANCE WITH
DEVELOPMENT GUIDELINES, DRAWINGS AND SPECIFICATIONS. ARCHITECTURAL/LANDSCAPING DRAWINGS AND RELEVANT
EXISTING LINEMARKING
AUTHORITY STANDARD DRAWINGS AND SPECIFICATIONS.
TO BE RETAINED FH FOOTPATHS TO BE CONSTRUCTED WITH MAXIMUM 2.5%
3. ALL DRAINAGE CONSTRUCTION (PRIVATELY OWNED DRAINAGE
0
0. LINES INTERNAL TO THE SITE BOUNDARIES) CONSTRUCTED CROSSFALL. SHOULD CONSTRUCTED FOOTPATHS EXCEED 2.5%
ExT
12
AND TESTED TO BE IN ACCORDANCE WITH RELEVANT CROSSFALL, THE CONTRACTOR WILL BE REQUIRED TO RECTIFY
3
AUSTRALIAN STANDARDS. BY REMOVING AND REPLACING AT THEIR COST.
RP52184
PP
ExW
4. ALL STORMWATER DRAINAGE PIPES INTERNAL TO SITE SHALL 14. CONCRETE FOOTPATH TO BE 100mm THICK N32 WITH SL72
BE: Ø225 RRJ RCP OR APPROVED EQUIVALENT. MESH IN ACCORDANCE WITH NSC STD DWG RS065, AS1679 AND
Ex
AS3600 UNO
W
.4
120
C
5. ALL STORMWATER PIPES ARE TO BE MANUFACTURED TO
H
O/H E
CRE
O/H E
RELEVANT AUSTRALIAN STANDARDS INCLUDING BUT NOT 15. THE CONTRACTOR IS TO CONFIRM THE LOCATION AND DEPTH
0.00
PROPOSED VEHICLE CROSSOVER LIMITED TO AS4058 AND AS1992. OF ALL SERVICE CONDUITS IN VERGE PRIOR TO COmmENCING
S
6.0
IN ACCORDANCE WITH IPWEA
0
T
11
WORKS. THE SUPERINTENDANT IS TO BE NOTIFIED OF ANY
ExT
4.77
STANDARD DRAWING RS-051
8
5.
11
6. STORMWATER DRAINAGE AND STRUCTURES HAVE BEEN CONFLICTS WITH WORKS IDENTIFIED IN THESE PLANS
120
IMMEDIATELY.
.
1
6
DESIGNED FOR OPERATIONAL LOADS ONLY. CONTRACTOR TO
12
ExW
0. PP CONSIDER CONSTRUCTION LOADINGS AND ENSURE NO
6
Ex
EXCESSIVE LOADS ARE PLACED ON STORMWATER DRAINAGE 16. ALL TRENCH EXCAVATION AND CONSTRUCTION SHALL COMPLY
SAGP 18.5
W
Ex
.8
Ex
OR STRUCTURES. WITH THE REQUIREMENTS OF THE QUEENSLAND WORKPLACE
Ex
120
E
T
W
E
HEALTH AND SAFETY ACT 2011.
.8
1
120
PROPOSED 2.0m
8.0837
.6
7. CONTRACTOR TO CONFIRM LOCATION AND LEVEL OF EXISTING
120
116.8
WIDE FOOTPATH
3
5.
0 STORMWATER DRAINAGE WHERE CONNECTING ON TO 17. REMOVE ANY REDUNDANT DRAINAGE OUTLETS FROM THE KERB
1200. CH 11 114.8
. 8
.4
120.4
121
O/H E
121 EXISTING. AND CHANNEL INCLUDING ANY ASSOCIATED PIPEWORK
112
ExT
2
.0
0.0 4
121.0 ACROSS THE FOOTWAY AND REINSTATE THE KERB AND
00 TP RP112204
0.5 2 8. CONTRACTOR TO NOTIFY THE SUPERINTENDENT OF ANY CHANNEL AND THE FOOTWAY AREA IN ACCORDANCE WITH
R3 80 NEW 2m FOOTPATH TO TIE
COUNCIL GUIDELINES.
.2
UNSUITABLE FOUNDING MATERIAL WITHIN DRAINAGE TRENCH
Ex W
.00
119
INTO EXISTING VERGE AND
114.2
.2
121
CR
Ex
0 EST FOOTPATH. OR STORMWATER STRUCTURES AND AWAIT DIRECTION PRIOR
D
1 .2
Ex
12
.0
113.4
W
115.6
18. ROADBASE MATERIAL SHOULD BE PLACED IN LAYERS AT LEAST
113
TO LAYING OF PIPES.
121.4
Ex
12
Ex
2
E
O/H E
3.8
115
ST
120
4.0
1.2
75 mm THICK BUT NOT EXCEEDING 150 mm IN THICKNESS, AND
W
26 xS
E
11
LOW FLOW DIRECTED TO E
115.2
.4
.8 WM
PROPOSED COMPACTED TO A MINIMUM DENSITY OF 95% OF THE MAXIMUM
12
PP
E
15KL TANK. WEIR TO 9. ALL STORMWATER GRATES/LIDS WITHIN TRAFFICABLE AREAS
CARPARKS. 121.21.4
0.6
PL
.4
12 TO BE CLASS "D" IN ACCORDANCE WITH AS3996. DRY DENSITY AS DETERMINED IN ACCORDANCE WITH
118.6
116
12
REFER DRAWING BYPASS HIGH FLOW 1TO
6.2
118.0
17 AUSTRALIAN STANDARD AS1289.6.2.
MA
0.
2 .0
118.2
C049 FOR DETENTION TANK 11
8
ExT
.0
PAVEMENT 116 10. ALL GRATES AND LIDS SHALL SIT FLAT WITH ITS SURROUND
O/H E
19. CONTRACTOR TO UNDERTAKE ROADWORKS TESTING IN
115.0
DETAILS 121 .6 AND NOT BE LOOSE OR MOVE UNDER WHEEL LOADS.
121.4 ACCORDANCE WITH NOOSA SHIRE COUNCIL GUIDELINES,
11
D
8.
ExW
121.0
DRAWINGS AND SPECIFICATIONS.
121.2
0
115.8
121.4
Ex
121.6 11. ALL STORMWATER STRUCTURES TO BE CONSTRUCTED IN
121.6
Ex
.6
W
114.8
Ex
ACCORDANCE WITH PROJECT SPECIFICATION, AND LOCAL
Ex
1 18
E
20. INTERNAL CONCRETE TO BE 125mm THICK (EXCLUDING
E
121.6
W
.8 AUTHORITY GUIDELINES AND SPECIFICATIONS. WHERE FINISHED TREATMENTS) N32 IN ACCORDANCE WITH AS1379 AND
121
/
STRUCTURES EXCEED MAXIMUM DEPTH AS IDENTIFIED WITHIN
ExS
AS3600. SL72 MESH MIN 50mm TOP COVER TO AS1304. MIN
D
114.6
121.8 S STANDARD DRAWINGS THE CONTRACTOR WILL ENSURE AN
.6
100mm BASE COURSE WHERE SUBGRADE CBR <=6. LOCATION
115
ADEQUATE STRUCTURAL DESIGN IS UNDERTAKEN FOR THE AND TYPE OF INTERNAL CONCRETE JOINTS TO CONFORM TO
ExT
121.8
TP
SUBJECT STRUCTURE TO BE CONSTRUCTED TO.
114.4
STRUCTURAL ENGINEERS SPECIFICATION.
2.0
CH
63.
12
122.0
CH
LOT 1 See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Approved Plans - MCU23/0007 & RAL23/0007 (As Published).pdfRelated documentApplication case desk ↗
About this file
- File size
- 16.8 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.