Council archive · source document
Operational Works Application OPW22/0237 - DA Form 1 & Plans -7 Riverbreeze Ave Noosa Heads
Plans and drawings: the text below has words only, no drawings.
•-Sr
NOTES
All construction to comply with the BCA and be
in accordance with AS 1684.2
N2 wind classification
CANAL rib
architects
% SB
.■Hughes Bu>U Envxonmcnts
169°12'40''
Written dimensions to take precedence over > ?3 0 T
scale.
Builder to check all dimensions, heights and levels 'I o
-
on site prior to commencing construction. /
ft
These plans to be read in conjunction with : 54 Bellata Street \
! The GepQLD 4061
engineers details.
a) RC slab and footings
b) wall framing / lintels
t P 0733003596
M 0402 038 082
hbtasdiitcrtstgoptusneuonxau'
c) floor framing 2-25
d) wall bracing and tie -down fixings \ 15
2-7S
30 \
WC doors to have lift off hinges. \N
Hardwire smoke detectors to be hardwired and
\ /
interconnected comply
with AS 3786-2014
r / *|--------- T
TERMITES / [i LOT 33
Termi-mesh system to AS 3660 parts 1,2,3 and to : / 3.0 RP 839220
manufactures specification or approved equal. i /
AREA 851m5- CO UJ
SUSTAINABILITY
2
dPol
Shower roses to have a 3 star rating under Weis. O
\ O
Dual flush toilets. PR0P0SED\ II H >
Energy efficient compact LED light fittings.
Hot water system with a 5 star rating.
ft o
Ol ft I ALTERATIONS^* AdDITIOHS h & SQ m <
TO RESIDENCE R dp
EXISTING GR RL 3T 1 k k V. O9 <
+ 2 o
CD
LININGS / r ■
10 mm plasterboard to ceilings.
ir \ \ X- t EXISTING RESIDENCE F00TPR! CO
2
10 mm plasterboard to walls.
6 mm Villaboard to wet area walls , garage and
i >------ /- r
SHOWN SHADED z LLl ul
/ / .1500.
v- o ID
i= D 2
store walls.
10 mm wet area plasterboard to external ceilings / CONNECT OOWNPIPES TO UJ
4.5 mm Hardiflex to soffits with 20 % decorvents. EXISTING STORMWATER
Cornice to be square set plaster. SYSTEM TO STREET
4
l
CLADDINGS ,13 "30 k LLJ uj
Selected weatherboards to external walls.
I
I -1 Xy N
< Qf UJ
6mm Harditex to planter wall with stone veneer
I LU
i Q Ql
dp
WINDOWS
Windows and doors to be aluminium framed units
>4---------- T UJ
O) LU m
as selected from the standard range.
o
60. -J £
DOORS o < ^DC
The entrance . garage and laundry doors to be ply Tii DC.
faced solid core doors as selected.
4 Q_ Q to-
Cl. sewer mh
Internal doors to be hollow core hardboard faced 23 0
flush panel door-s 349o12'40 " JPetec
p-t ■—> TJ hydront -
INSULATION
Provide 60 mm foil backed Anticon insulation
date
under the roof sheeting to manufacturers FH'2!
specification. In addition provide R3.5 Bradford or drawn
equal baits above the ceiling to manufactures 7 RIVERBREEZE AVENUE
specification. scale
Wall insulation to be R1.5 batts l-7 Up l
SITE PLAN L200 sheet
job No.
21~25p
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Operational Works Application OPW22/0237 - DA Form 1 & Plans -7 Riverbreeze Ave Noosa HeadsRelated documentApplication case desk ↗
About this file
- File size
- 6.3 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.