Log in to see the plans as drawn UNIT B - G.F. AREAS UNIT A - G.F. AREAS
Ground Floor Residence : 90.3m² Ground Floor Residence : 89.3m²
Entry : 2.3m² - Entry : 2.9m²
Outdoor Entertaining: 6.9m² APPROVED PLAN Outdoor Entertaining: 11.8m²
MCU20/0097
Ground Floor Total : 99.5m²
NOOSA COUNCIL Ground Floor Total : 104.0m²
21 JANUARY 2021 T H
-
NOR
Landscape
Motorised Gate Water Feature
APPROVAL RELATES TO
- GENERAL NOTES
Turning Bay UNIT A ONLY The builder is responsible to check all
existing services prior to beginning any
L and -
scape construction.
Pool
4000
# Denotes cavity slider to manufactuers
specification, frames containing cavity sliders
to be 90mm minimum U.N.O
Turf/Landscape
Pool fence
Builder to verify all dimensions prior to
beginning construction work.
Pool Fence
Electric HWS to minimum energy efficiency
2427 pl regulations.
Toilets: minimum 4-star dual flush, as rated
Entry Pool
Pool fence
Outdoor under the Water Efficiency and Labeling
Standards scheme (WELS).
Entertainment Line of balcony over
1200 pvt Landscape Tapware: minimum 3-star WELS rated for
1.8m fence/gate Outdoor kitchen sinks, basins and laundry troughs.
2427 stk
Entertainment 4/2406 lvr
Turf/Landscape
Showerheads: minimum 3-star WELS rated
Bin Storage
Garage showerheads.
Vo
2700 Ceiling
2406 lvr
id
2440 stk
ov
2400 Joinery SD
er
Smoke alarms complying with AS 3786
Line of floor over
3.2m x 6.0m Living
OHC
to be installed and connected to consumer
tv
4.8m x 3.6m Living Turning Bay/ mains power in accordance with NCC part
tv
3.5m x 3.3m Carpark 3.7.2
Vo
id o
Dining
2406 lvr
ve r All electrical appliances and plumbing symbols
Kit 3.0m x 4.6m are diagrammatical. Refer to builders
specification for details all fixtures.
770 cs Unit B Line of floor over
3/ 2103 fg
Seal wet areas in accordance with N.C.C. Vol. 2.
FRl 60/60/60
1200 pvt
Landscape Dining Unit A
720 Part 3.8.1. Slope floor surface towards fw
Storage 2700 Ceiling Entry (floor wastes)
Under 2400 Joinery 770 cs Provide lighting in accordance with N.C.C. Vol. 2.
4.8m x 3.0m. Part 3.8.4.2 & 3
1206 dh
shelves Provide ventilation in accordance with N.C.C.
Motorised Gate
Storage
Under
770
shelves
Pty Garage Vol. 2. Part 3.8.5
fr
770 Pty Mechanical ventilation in accordance with N.C.C
820 cs 2700 Ceiling
2430 pl
dr Vol. 2. and AS1668.2
2400 Joinery
820 cs
720 cs
Ldy wm 3.2m x 6.0m
wm Kitchen dr
Ldy Line of floor over
1206 dh
fr 3/ 2103 fg
Landscape
OHC Dimensions Note:
820 All wall dimensions are taken from
Glass Clothes Line
1.8m fence
the outside faces of the stud wall.
fence/gate
0606 lvr 0606 lvr 0606 lvr 0606 lvr 2415 sd 0906 dh
(i.e. selected cladding over omitted for
1.8m
clarity excluding brick veneer walls).
Clothes Line Bin Storage
Climate Code Requirements
Energy efficiency assessor to confirm
PROPOSED GROUND FLOOR PLAN adequacy of proposed construction.
Provide insulation to N.C.C. code requirements
or to BERS certification requirements.
C COPYRIGHT The Drawing and the design depicted on this sheet remains the property of Icon Building design. Reproduction in part or whole is prohibited unless written permission is obtained from Icon Building Design. Plans are design for use on the job address specified in the titleblock only.
Revision Schedule Client Name: Andy & Pamela Pannifex
Sheet Number:04 Project Number:18-076
Revision Number Revision Description Revision Date Issued by Project Address: No. 27 Hill Street, Sunshine Beach
1 PCD 2 05/02/2019 BJH
Climate Zone: 2
2 PCD 3 28/02/2019 AOW
Wind Category: To engineers spec.
Ground Floor
Email: [email protected] 3 Concept Set 1.1 03/03/2019 BJH
Website: www.iconbuildingdesign.com.au 4 Development Application 03/05/2019 BJH Project Issue Date: 03/05/2019 Project Status: Development Application 1.0 Scale: 1 : 100
1.0
Phone:Set
0488209840 Checked/Signed By Director: Bradley Hunt Drawn By: BJH QBCC LIC# 126221
Document ID: 21247240
Version: 1, Version Date: 24/09/2020
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.
Full text of the other 3 pages
Page 2
-
UNIT B - F.F. AREAS
First Floor Residence (Exc. Voids) : 55.1m²
APPROVED PLAN
First Floor Residence (Exc. Voids) : 53.8m²
Balcony : 8.8m² MCU20/0097 Balcony : 12.1m²
NOOSA COUNCIL
First Floor Total : 63.9m² 21 JANUARY 2021 First Floor Total : 62.0m²
- T H
Overall Total : 163.4m² Overall Total : 166.0m² NOR
- GENERAL NOTES
APPROVAL RELATES TO
UNIT A ONLY The builder is responsible to check all
existing services prior to beginning any
-
construction.
# Denotes cavity slider to manufactuers
specification, frames containing cavity sliders
to be 90mm minimum U.N.O
Builder to verify all dimensions prior to
beginning construction work.
Face fixed glass balustrade Face fixed glass balustrade
Electric HWS to minimum energy efficiency
regulations.
Void Over
2436 stk Roof
Toilets: minimum 4-star dual flush, as rated
2418 sd
Balcony Face fixed glass balustrade
under the Water Efficiency and Labeling
Feature Screen Over Standards scheme (WELS).
Bed 1 r
4.3m x 3.7m oid Ove
Roof V
Tapware: minimum 3-star WELS rated for
Ra
kitchen sinks, basins and laundry troughs.
Balcony
k
2406 lvr 2406 lvr 2406 lvr
ed
4/2406 lvr
Feature Screen Over
Showerheads: minimum 3-star WELS rated
2406 lvr
robe 2427 stk showerheads.
1206 shutter
Vo
SD
Smoke alarms complying with AS 3786
Ra
id
FRL 60/60/60
ov
ke
ng
to be installed and connected to consumer
er
d
livi
820
Glass Balustrade
0606 lvr
liv i
mains power in accordance with NCC part
er
Ens
robe
Bed 1
ng
ov
3.7.2
2406 lvr
id
2700 Ceiling
Vo
3/1206 shutter 2400 Joinery All electrical appliances and plumbing symbols
3.3m x 3.8m 1506 lvr are diagrammatical. Refer to builders
Glass Balustrade 3/1206 shutter
specification for details all fixtures.
820
3/ 2103 fg
Void
820
820
Seal wet areas in accordance with N.C.C. Vol. 2.
Bed 2 1206 shutter
Part 3.8.1. Slope floor surface towards fw
DN 3.7m x 3.1m
4/1506 lvr
robe (floor wastes)
DN
Provide lighting in accordance with N.C.C. Vol. 2.
Ens Bed 2
0606 lvr
770 cs
Ens Part 3.8.4.2 & 3
770
Ens 3.2m x 3.5m Provide ventilation in accordance with N.C.C.
Vol. 2. Part 3.8.5
robe Mechanical ventilation in accordance with N.C.C
Vol. 2. and AS1668.2
Dimensions Note:
0606 lvr 1806 lvr 0606 lvr
0604 lvr
All wall dimensions are taken from
Roof Below Roof Below the outside faces of the stud wall.
3/ 2103 fg Roof Below (i.e. selected cladding over omitted for
clarity excluding brick veneer walls).
Climate Code Requirements
Energy efficiency assessor to confirm
adequacy of proposed construction.
PROPOSED FIRST FLOOR PLAN Provide insulation to N.C.C. code requirements
or to BERS certification requirements.
C COPYRIGHT The Drawing and the design depicted on this sheet remains the property of Icon Building design. Reproduction in part or whole is prohibited unless written permission is obtained from Icon Building Design. Plans are design for use on the job address specified in the titleblock only.
Revision Schedule Client Name: Andy & Pamela Pannifex
Sheet Number:05 Project Number:18-076
Revision Number Revision Description Revision Date Issued by Project Address: No. 27 Hill Street, Sunshine Beach
1 PCD 2 05/02/2019 BJH
Climate Zone: 2
2 PCD 3 28/02/2019 AOW
Wind Category: To engineers spec.
First Floor
Email: [email protected] 3 Concept Set 1.1 03/03/2019 BJH
Website: www.iconbuildingdesign.com.au 4 Development Application 03/05/2019 BJH Project Issue Date: 03/05/2019 Project Status: Development Application 1.0 Scale: 1 : 100
1.0
Phone:Set
0488209840 Checked/Signed By Director: Bradley Hunt Drawn By: BJH QBCC LIC# 126221
Document ID: 21247240
Version: 1, Version Date: 24/09/2020
Page 3
Frameless glass balustrade with aluminium
Select 67 x 15 P.C. Aluminium
handrail in accordance with NCC regulations
batten screen @ 100mm crs to
fixed to manufacturers specification.
manufacturers detail.
Min. 1000mm high.
600 600 Rendered foamboard cladding fixed to
Colorbond Custom orb roof sheeting 600 manufacturers specification.
fixed to manufacturers specification
for required wind category. (5° pitch).
Aluminum framed windows
to manufacturers specification. Feature beam to engineers detail with
selected EPS sunhood/feature fixed to
beam to manufacturers specification.
Aluminum framed Doors
to manufacturers specification.
Ceiling Height
Frameless glass balustrade with aluminium
2700
Joinery
2400
handrail in accordance with NCC regulations
fixed to manufacturers specification.
Min. 1000mm high.
200 series blockwork wall to
engineers detail. Lined with Axon
Cladding.
Ceiling Height
2700
Rendered brick veneer
Joinery
2400
walls to engineers details.
-
APPROVED PLAN
Select Fence fixed to
MCU20/0097
manufacturers detail. NOOSA COUNCIL
1.8m max height NORTH ELEVATION 21 JANUARY 2021
-
-
APPROVAL RELATES TO
Colorbond Custom orb roof sheeting 600 600 600 600 600 UNIT A ONLY
fixed to manufacturers specification -
for required wind category. (5° pitch).
Rendered foamboard cladding fixed to 200 series blockwork wall to
manufacturers specification. engineers detail.
Select 67 x 15 P.C. Aluminium
batten screen @ 100mm crs to
Ceiling Height
manufacturers detail.
2700
Joinery
2400
Select P.C. Aluminium batten
screen and post to manufacturers
and engineering detail.
Rendered brick veneer
walls to engineers details.
Ceiling Height
2700
Joinery
2400
EAST ELEVATION
C COPYRIGHT The Drawing and the design depicted on this sheet remains the property of Icon Building design. Reproduction in part or whole is prohibited unless written permission is obtained from Icon Building Design. Plans are design for use on the job address specified in the titleblock only.
Revision Schedule Client Name: Andy & Pamela Pannifex
Sheet Number:06 Project Number:18-076
Revision Number Revision Description Revision Date Issued by Project Address: No. 27 Hill Street, Sunshine Beach
1 PCD 2 05/02/2019 BJH
Climate Zone: 2
2 PCD 3 28/02/2019 AOW
Wind Category: To engineers spec.
Elevations
Email: [email protected] 3 Concept Set 1.1 03/03/2019 BJH
Website: www.iconbuildingdesign.com.au 4 Development Application 03/05/2019 BJH Project Issue Date: 03/05/2019 Project Status: Development Application 1.0 Scale: 1 : 100
1.0
Phone:Set
0488209840 Checked/Signed By Director: Bradley Hunt Drawn By: BJH QBCC LIC# 126221
Document ID: 21247240
Version: 1, Version Date: 24/09/2020
Page 4
-
600 600 600 600 600 APPROVED PLAN
MCU20/0097
Colorbond Custom orb roof sheeting NOOSA COUNCIL
fixed to manufacturers specification 21 JANUARY 2021
for required wind category. (5° pitch). -
Colorbond slotted gutter, fascia
to match roofing. Fix to manufacturers
specification.
Rendered foamboard cladding fixed to
Ceiling Height
manufacturers specification.
2700
Joinery
2400
Aluminum framed windows
600 to manufacturers specification.
Rendered brick veneer
Ceiling Height
walls to engineers details.
2700
Joinery
2400
Unit B F.F.L.
600
Unit A F.F.L.
Approx. Existing Ground Line.
Approx. Proposed Ground Line.
Colorbond Custom orb roof sheeting
SOUTH ELEVATION
fixed to manufacturers specification -
for required wind category. (5° pitch). APPROVAL RELATES TO
600 600 600
Colorbond slotted gutter, fascia UNIT A ONLY
to match roofing. Fix to manufacturers -
specification.
5°
Approved frameless glass pool fence to
200 series blockwork wall to engineers
manufacturers specifications.
detail.
Min. 1200mm high.
Rendered foamboard cladding fixed to
Ceiling Height
manufacturers specification.
2700
Joinery
2400
Aluminum framed windows
5° to manufacturers specification.
Ceiling Height
2700
Joinery
2400
Rendered brick veneer
walls to engineers details.
Approx. Proposed Ground Line.
Approx. Existing Ground Line.
WEST ELEVATION
C COPYRIGHT The Drawing and the design depicted on this sheet remains the property of Icon Building design. Reproduction in part or whole is prohibited unless written permission is obtained from Icon Building Design. Plans are design for use on the job address specified in the titleblock only.
Revision Schedule Client Name: Andy & Pamela Pannifex
Sheet Number:07 Project Number:18-076
Revision Number Revision Description Revision Date Issued by Project Address: No. 27 Hill Street, Sunshine Beach
1 PCD 2 05/02/2019 BJH
Climate Zone: 2
2 PCD 3 28/02/2019 AOW
Wind Category: To engineers spec.
Elevations
Email: [email protected] 3 Concept Set 1.1 03/03/2019 BJH
Website: www.iconbuildingdesign.com.au 4 Development Application 03/05/2019 BJH Project Issue Date: 03/05/2019 Project Status: Development Application 1.0 Scale: 1 : 100
1.0
Phone:Set
0488209840 Checked/Signed By Director: Bradley Hunt Drawn By: BJH QBCC LIC# 126221
Document ID: 21247240